POWX902 EN
Copyright © 2022 VARO NV P a g e | 7 www.varo.com
turn the Emergency switch (15) clockwise, which will unlock the Emergency switch (15).
The cable hoist is now operational.
▪ The cable hoist is designed with limit configuration to limit stop. When load hook (12) is
hoisting up to topmost position, the stopper (10) touch the lift limit bracket (8), the micro
switch of lift limit bracket (8) can cut off the circuit and make the motor stop to insure the
safety of operations. When load hook (12) is lowering down nearly to use up the cable (7),
the micro switch of down limit bracket (9) start work and cut off the circuit and make the
motor stop.
Attention! If the cable has been unwound to the point where the red micro
switch is visible, the cable hoist must be stopped. Under no circumstances
should the cable be unwound past this point'
▪ If the cable hoist cannot hoist a load immediately, switch it off immediately to prevent
damages and accidents.
▪ Please be sure that the load is securely fastened to the load hook (12-13). Maintain the
largest possible distance to the load and steel cable (7) during operation.
▪ Upon lowering a load, please remember that the cable hoist may still unwind a few more
centimetres after it was stopped. Therefore, please stop in sufficient time.
▪ Please be sure that the steel cable (7) cannot be moved more than 15° to the side.
▪ The cable hoist can be operated with a single or double cables, therefore the permissible
rated load, see Technical Specifications, can vary.
▪ After unpacking the items, check to make sure that all pieces and accessories correspond
with the directions. Check to see if the cable hoist has any dents or damage, if the cable
connections have any defects and if the motor shows any signs of rain or water damage.
▪ The cable hoist uses a single-phase energy power supply. The nominal voltage is 230V +
20%, the nominal frequency is 50Hz + 1%. The motor must be safely grounded. In the
circuitry of the power supply an over-current protection must be installed.
▪ After connecting the power supply, the pulley can then be raised and lowered in Jog-
mode. One can raise and lower start-up during a dry-run. First when the up and down
movement is stable and the brakes work flawlessly, once can test the pulley with a dummy
load.
9.1 Intermittent rating
This machine is designed for operating type S3 20% - 10 min (periodic intermittent operation).
The relative duty cycle is 20%, which means that the device can be operated at rated load for
2.0 minutes during each operating cycle and must then be switched off for 8. 0 minutes to cool
off. The device can therefore be continuously used for a duration of 20% of the total operating
cycle of 10 minutes at rated load.
9.2 Overload (Only for POWX901-POWX902-POWX903)
▪ The cable hoist is not suitable for continuous operation. The motor is protected from
overload and overheating by a temperature switch.
▪ If the permissible operating time is exceeded, the motor temperature will increase and the
temperature switch will shut the cable hoist off. The temperature switch will automatically
switch back on after a cooling phase.
▪ In case of a strain on the cable hoist with a lesser load, the operating time will increase
and the cooling time will decrease.