POWX07590 EN
Copyright © 2023 VARO P a g e | 13 www.varo.com
10.3.1 Fitting and changing the saw blade (Fig. 8)
Caution! Unplug from power source.
Caution! Ensure that the saw housing is well lit.
▪ Remove the screw (24) of the front of the table insert.
▪ Remove the table insert
▪ Use the crank and turn to the left to bring the saw blade as far up as it will go.
▪ Use the spanners (14) to remove the screw on the saw blade and exchange the blade
with a suitable replacement. Watch the direction of operation! See the arrow on the saw
blade. The teeth must point towards the on/off switch (1).
10.3.2 Adjusting the cleaving wedge (Fig. 9)
The gap between the external edge of the saw blade and the cleaving wedge (8) must be
between three and five millimetres.
▪ Bring saw blade angle to the 0° position and tighten.
▪ Bring the saw blade into the upper position.
▪ Remove the saw blade protector.
▪ Remove the table surface.
▪ Loosen the screw (A) slightly with a suitable combination spanner until the cleaving wedge
(8) is released (do not remove screw)
▪ Set the cleaving wedge lower or higher by pushing upward or downward in the long hole.
▪ Mount all dismantled parts in reverse sequence.
11 STORAGE, TRANSPORTATION
11.1 Storage
Risk of injury! Store the unit in such a way that it cannot be started by
unauthorised persons. Ensure that no one is able to injury themselves on
the stored unit.
Machine damage! Do not store unprotected in a damp environment.
12 TECHNICAL DATA