685340
7
Verklein
Vergroot
Pagina terug
1/7
Pagina verder
Manual: PTG Controller Quick Start Guide
1
MANUAL
PTG Controller
Quick Start Guide
Power Technology Southeast, Inc.
634 SR 44 W.
Leesburg, FL 34748
352-365-2777
Fax: 352-787-5545
www.powertech-gen.com
Manual: PTG Controller Quick Start Guide
2
Please read these instructions carefully prior to installing and operating this
generator. If you have any questions please feel free to contact us at 800-760-
0027 or via our website at www.powertech-gen.com
The use of any spare parts that are not genuine or not expressly authorized shall free
Power Technology Southeast, Inc. from any warranty liability and any responsibility
concerning conformity to regulations and relevant consequences.
Installation, after-sales modifications and maintenance must be carried out by
adequately trained staff.
Manual: PTG Controller Quick Start Guide
3
Table of Contents
1. Introduction .............................................................................................................. 4
2. Using the Controller ................................................................................................ 5
2.1. Front Panel Items
2.2. Using the Menu System
2.3. Modes, Starting and Stopping Methods
Manual: PTG Controller Quick Start Guide
4
1 Introduction
The PTG series controllers are designed to provide complete control, protection, AC
metering, and engine instrumentation for both standard and electronic engines. The
module is easily configured using either the front panel buttons. PTG series controllers
are ideally suited for severe duty applications where reliability is critical such as mobile
and stationary generators.
Manual: PTG Controller Quick Start Guide
5
2 Using the Controller
The LCD display is the primary source of information of the controller. The LCD allows
you to view/change settings and monitor the status of sensors and other engine
peripherals.
2.1 Front Panel Items
Item
Name
Description
Off Button
Used for turning off the engine or exiting out of
Auto mode. This is not intended to function as an
Emergency Stop as there are conditions in which
it will not shutdown the engine.
Auto Button
Used for placing the controller into Auto mode.
Once in Auto the controller waits for a start
command to be received.
Run Button
Used to start the engine manually. Must use the
Off button to shutdown the engine if started from
front panel.
Up Button
Used for moving around in the menu, changing a
settings value, or changing the currently displayed
parameter page.
Enter Button
Used for entering the menu system, accepting
settings, or locking the LCD screen when viewing
parameters.
Down Button
Used for moving around in the menu, changing a
settings value, or changing the currently displayed
parameter page.
Generator LED
Green = Engine running with no issues
Amber = Engine running with warnings
Red = Engine shutdown on failure
Manual: PTG Controller Quick Start Guide
6
2.2 Using the Menu System
Task
Entering Menu
Navigating Menu
Scroll Parameters
Lock Screen
Events History
2.3 Modes, Starting and Stopping Methods
The following table describes the different operating modes of the controller:
Modes
Mode / State
Description
OFF
When in the OFF mode, the engine cannot be remotely started.
Auto
When in the Auto mode, the engine waits to receive a start
command.
Running
When engine is Running, the controller monitors engine
parameters and waits to receive a stop command.
Failure
When a failure occurs, the controller shuts down the engine and
displays reason for failure. The unit must be reset using the front
panel OFF button with the exception of Modbus.
Menu
When in the menu you can change settings and view the events
history.
The following table describes the different methods in which a controller can start. The
controller must be in the AUTO mode in order to start for all methods with the exception
of Manual Run.
Manual: PTG Controller Quick Start Guide
7
Starting and Stopping Methods
Methods
Description
Manual Run
Pressing the Run button will start the engine. You must press
the OFF button to shutdown the engine.
Remote
Start / Stop Input
When in AUTO mode remote starting of the engine is enabled.
Battery Recharge
(optional)
When the battery voltage drops below a certain level the engine
will start and run for a predetermined amount of time.
Exerciser
(optional)
When the scheduled exerciser interval occurs the engine will
start and run for a predetermined amount of time.
Auxiliary Sensors
When a properly configured Auxiliary sensor falls below / rises
above a certain point the engine will start as determined by the
Auxiliary Sensors -> Mode Select settings.
NOTE: Required Start / Stop signal type (Maintain or Momentary) is requested
through Power Technologys Sales Department. For determining the Start / Stop
signal type, if unknown, please contact Power Technologys Customer Service.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw PowerTech PTG Controller bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van PowerTech PTG Controller in de taal/talen: Engels als bijlage per email.

De handleiding is 0,41 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info