Do not install and use your air conditioner before carefully reading this instruction guide. This will
help you to get the optimal and safe operation of your air conditioner FA15CS.
The following advice and instructions must be followed:
1. After unpacking place your appliance vertically upright to allow the cooling agent to stabilize
and it is important to wait 3 hours before use.
2. Your air conditioner FA15CS must always be used in an upright position, as it contains a coo-
ling agent.
Failure to respect these 2 instructions may damage the appliance and would invalidate the
Polti guarantee.
• The air conditioner must not be used in wine cellars or in any room with a temperature under
16°C.
TT
TT
EE
EE
CC
CC
HH
HH
NN
NN
II
II
CC
CC
AA
AA
LL
LL
DD
DD
AA
AA
TT
TT
AA
AA
• Type Split air conditioner
• Cooling capacity 15000 BTU / H - 4350 W /h
• Power requirement 1400W
• Cooling agent R22 -820 g
• Maximum air flow 530 m
3
/hour
• Fan speed 3
• Distribution of air flow Automatic or manual oscillation
• Dehumidification 2,0 l/h at 80% RH and at 30°C
• Controls electronic
• Thermostat accurate to 0,5°C
• Operating time programmable from 1 to 12 hours
• Delayed start programmable from 1 to 12 hours
• Air filter to collect dust easily removable, washable
• Length of the connecting sleeve 3 meters
• Indoor unit 4 swivel castors, 2 with a brake
• Outdoor unit 2 steel brackets for wall fixing
• Dimensions: indoor unit L 46 cm x H 88 cm x D 42 cm
outdoor unit L 54 cm x H 49 cm x D 33,5 cm
• Weight 52 kg
• Accessories provided 2 steel brackets for wall fixing (outdoor unit)
1 remote control
This appliance complies with the relevant requirements of the directives 89/336/CEE relating to
electromagnetic compatibility and 73/23/CEE relating to low voltage.