770992
5
Verklein
Vergroot
Pagina terug
1/19
Pagina verder
petsafe.com1-800-732-2677 98
Operating Guide
Step 1: Have Your Utilities Marked
1. Call your utility company to have your utility lines marked. If you
have neighbors using an in-ground pet containment system, you
will want to ask them where the boundary is located. Trust us, you
really do not want to skip this step.
2. Make a plan for how you will work around any large metal
objects (like sheds) or wires. You can cross utility lines but only at
90° angles (1A).
Note: Large metal objects and wires can amplify and/or modulate
radio signals in unpredictable ways.
Underground cables can carry high voltage. Have all underground cables marked before you dig to bury your wire. In
most areas, this is a free service. Avoid these cables when you dig.
Step 2: Charge the Receiver Collar
Open the rubber cap on the back of the receiver collar (2A). Plug
one end of the charger into the outlet and the other into the receiver
collar. The collar light is red while charging and green when fully
charged. The first charge will take about 2 or 3 hours. Each charge
can last up to 3 months depending on the frequency of use.
Do not charge your receiver collar every night.
Frequent charging can have a negative effect
on the battery. We recommend that the receiver
collar be used until the indicator light blinks red.
Step 3: Install the Surge Protector
and Transmitter
Lightning strikes that occur even several miles away from your
installation can create power surges or spikes which may damage
an unprotected system. The surge protector is included to safeguard
your YardMax® system against surges or spikes that can reach it via
your AC power connection and/or boundary wire.
1. Find a place to install the surge protector and transmitter. There
are a few things to consider when choosing an outlet for your
surge protector and transmitter:
We recommend using an outlet at least 30 ft. from the
breaker box.
Both the surge protector and transmitter should be indoors, in a
dry, ventilated and protected area.
The boundary wire must run from the transmitter and exit the
building, so place the transmitter near a window or a wall that
you can drill through (3A). The wire should not be pinched or
cross any utility lines.
The temperatures in that location should not fall below -10°F/-
23°C or above 104°F/40°C.
Both the surge protector and transmitter should be at least 3 ft.
from large metal objects or appliances (3B). These items may
interfere with the signal consistency.
In case your system sounds an alarm, place it where you will be
able to hear and access it.
10
Buried Cable
Boundary Wire
90°
10
1A
2A
Receiver
Charge Jack
1
AB
10
2
56
7
8
9
4
3
3A
B
10
7
8
9
3 ft.
3 ft.
3B
2. Once you have chosen an outlet and before plugging anything
in, go to your breaker box and turn the power off to that outlet.
3. Then, back at the outlet, remove the center screw that holds the
outlet cover in place.
4. Plug the surge protector into the lower outlet.
5. Using the large screw provided, secure the surge protector to
the outlet.
6. At the breaker box, turn the power back on to the outlet.
7. Next, you will mount the transmitter somewhere within 5 ft. of the
surge protector. Remove the mounting bracket from the back of
the fence transmitter.
8. Fasten the mounting bracket to the wall using the 2 screws and
anchors provided (3C).
9. Slide the transmitter over the mounting bracket (3D).
10. How to connect all the wires will be explained later in Step 6.
Do not install, connect or remove your system during a lightning storm. If the storm is close enough for you to hear
thunder, it is close enough to create hazardous surges.
Risk of electric shock. Use the fence transmitter and surge protector indoors in dry location only.
Turn off power to the outlet before you install or remove your surge protector.
Risk of electric shock or fire. Use surge protector only with a duplex outlet with center screw.
Do not install the surge protector if there is not at least 30 ft. (10 m) or more of wire between the electrical outlet
and electrical service panel.
If possible, DO NOT use an AC circuit protected with a GFCI (ground fault circuit interrupter). Both the surge
protector and the fence system will function. However, in rare cases, nearby lightning may cause the GFCI to trip.
Without power, your pet may escape. You will have to reset the GFCI to restore power to the system.
Plug the surge protector into a grounded (3-prong) outlet within 5 ft. of the fence transmitter. ALWAYS use a
grounded (3-prong) outlet to ensure protection.
Do not remove the ground prong from the surge protector plug. Do not use a 3-prong plug to 2-prong outlet
converter. Doing so will make the surge protector ineffective against surges or spikes.
For added protection, when unused for long periods of time or prior to thunderstorms, unplug from the wall outlet
and disconnect the loop boundary wires. This will prevent damage to the transmitter due to surges.
Mounting
Bracket
1
A B
10
2
56
7
8
9
4
3
3C 3D
1
A B
10
2
56
7
8
9
4
3
A
B
Power
Indicator Light
Power
Switch
Power
Jack
Wire Break
Warning Light
Boundary
Width Dial
Mode
Selection
Switch
Loop Wire
Terminals
Red Black
YardMax®
Mode
(Mode A)
Traditional
Mode
(Mode B)
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Petsafe PIG00-11116 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Petsafe PIG00-11116 in de taal/talen: Engels als bijlage per email.

De handleiding is 3.48 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info