GB/
MT
54
11. Possible causes of failure
Problem Cause Solution
The compressor does not
start.
1. No supply voltage.
2. Insufficient supply voltage.
3. Outside temperature is too
low.
4. Motor is overheated.
1. Check the supply voltage,
the power plug and the
socket-outlet.
2. Make sure that the
extension cable is not too
long. Use an extension cable
with large enough wires.
3. Never operate with an
outside temperature of
below +5° C.
4. Allow the motor to cool
down. If necessary, remedy
the cause of the overheating.
The compressor starts but
there is no pressure.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for
condensation water (9)
leaks.
1. Have a service center
replace the non-return valve.
2. Check the seals and have
any damaged seals replaced
by a service center.
3. Tighten the screw by hand.
Check the seal on the screw
and replace if necessary.
The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.
1. The hose connections have
a leak.
2. A quick-lock coupling (4, 20)
has a leak.
3. Insufficient pressure set on
the pressure regulator (3).
1. Check the compressed air
hose and tools and replace if
necessary.
2. Check the quick-lock
coupling and replace if
necessary.
3. Increase the set pressure
with the pressure regulator.