706349
10
Verklein
Vergroot
Pagina terug
1/68
Pagina verder
5GB/IE/NI
Personal safety
Pay attention to what you are doing and use
power tools sensibly.
Do not use power tools when you are tired or
under the influence of drugs, alcohol or medi-
cation. A single moment of inattention while using pow-
er tools may cause severe injury.
b) Wear personal protective equipment and safe-
ty goggles.
Wearing personal protective equipment such as a dust
mask, non-skid safety boots, a protective helmet or hear-
ing protection according to the type and application of
the power tool reduces the risk of injury.
c) Avoid starting the power tool unintentionally.
Make sure that the power tool is switched off
before you connect it to the mains and/or in-
sert a battery, pick it up or carry it. lf you have
your finger on the switch when you carry the power tool,
or if the machine is switched on when you connect it to the
mains, this may result in accidents.
d) Remove adjustment tools or wrenches before
switching on the power tool.
Tools or wrenches in rotating machine parts may cause
injury.
e) Avoid abnormal body positions.
Stand securely and keep your balance at all
times. By doing so, you can control the power tool more
easily in unexpected situations.
f) Wear suitable clothing. Do not wear loose
clothing or jewellery. Keep your hair, cloth-
ing and gloves away from moving parts. Loose
clothing, jewellery or long hair may be trapped in moving
parts.
g) lf dust extraction tools or collection bins can
optionally be attached, you must make sure
that they are connected and correctly used.
Using dust extraction tools may reduce risks caused by
dust.
h) Do not let familiarity gained from frequent use
of the tool allow you to become complacent
and ignore tool safety principles. A careless ac-
tion can cause severe injury within a fraction of a second.
Use and treatment of the power tool
a) Do not overload the tool.
Use the appropriate power tool for your type of work.
With appropriate power tools, you can work better and
more safely within the given power range.
b) Do not use the power tool if the switch does
not turn it on and off. Any power tool that can-
not be controlled with the switch is dangerous
and must be repaired.
c) Disconnect the plug from the power source
and/or remove the battery pack, if detach-
able, from the power tool before making any
adjustments, changing accessories, or storing
power tools.
This preventive safety measure reduces the risk of starting
the power tool accidentally.
d) Store idle power tools out of the reach of chil-
dren.
Do not allow persons unfamiliar with the power tool or
these instructions to operate the power tool. Power tools
are dangerous in the hands of untrained users.
e) Carefully maintain power tools and accesso-
ries.
Check moving parts for proper function and smooth run-
ning, and check whether there are parts which are bro-
ken or damaged to the extent that the functionality of the
power tool is impaired. Have damaged parts repaired
before using the power tool. Many accidents are caused
by poorly-maintained power tools.
f) Keep cutting tools sharp and clean. Carefully
maintained cutting tools with sharp edges are
less likely to jam and can be guided more eas-
ily.
g) Use power tools, accessory parts, insertion
tools, etc. in compliance with these instruc-
tions.
Take into account the working conditions and the activity
which is to be carried out. Using power tools for appli-
cations other than those intended may cause dangerous
Situations.
h) Keep handles and grasping surfaces dry,
clean and free from oil and grease. Slippery han-
dles and grasping surfaces do not allow for safe handling
and control of the power tool in unexpected situations.
Service
a) Have your power tool repaired by qualified
specialists only, and always use original spare
parts for repair. This is to maintain the safety of the
power tool.
Warning! This electric tool generates an electromagnetic field
during operation. This field can impair active or passive medi-
cal implants under certain conditions. In order to prevent the
risk of serious or deadly injuries, we recommend that persons
with medical implants consult with their physician and the man-
ufacturer of the medical implant prior to operating the electric
tool.
Safety instructions for mitre saws
a) Mitre saws are intended to cut wood or wood-
like products, they cannot be used with abra-
sive cut-off wheels for cutting ferrous material
such as bars, rods, studs, etc. Abrasive dust causes
moving parts such as the lower guard to jam. Sparks from
abrasive cutting will burn the lower guard, the kerf insert
and other plastic parts.
b) Use clamps to support the workpiece when-
ever possible. If supporting the workpiece by
hand, you must always keep your hand at least
100 mm from either side of the saw blade. Do
not use this saw to cut pieces that are too small
to be securely clamped or held by hand. If your
hand is placed too close to the saw blade, there is an in-
creased risk of injury from blade contact.
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Parkside MPKZ 2000 A1 - IAN 315340 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Parkside MPKZ 2000 A1 - IAN 315340 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 2,81 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info