5. Safety information
1. No modifications are allowed to be made to the genera-
tor
2. The speed preset by the manufacturer may not be
changed. The generator or connected devices could be
damaged.
3. Risk of poisoning! Fumes, fuels and lubricants are
toxic. Do not breath in the fumes.
4. Fire risk! Petrol and petrol fumes are highly flammable
and explosive.
5. Motor exhaust gases are toxic. The generator must not
be operated in unventilated rooms. If the generator is to
be operated in well-ventilated rooms, the exhaust gases
must be discharged directly outside via an exhaust gas
hose. Additional requirements for protection against fire
and explosion must also be observed. Even when using
an exhaust hose, toxic gas can still escape. Due to the
risk of fire, the exhaust hose should never be aimed at
combustible material.
6. Never use the generator in rooms with highly flammable
materials.
7. Hot surface! Risk of burning, do not touch the exhaust
system and engine unit.
8. Do not touch any of the mechanically moving or hot parts.
Do not remove any of the protective caps.
9. Protective equipment! Use suitable ear protection
when near the device.
10. Only original parts should be used for maintenance and
accessories.
11. Repair and maintenance work must only be performed by
authorised qualified personnel.
12. Protect yourself from electric shocks.
13. Never touch the generator with wet hands
14. Only use outside with a extension cable which is suitable
for that and is appropriately marked (H07RN).
15. If extension cables or mobile distribution networks are
used, the resistance value must not exceed 1.5 Ω. When
using extension cables, the total length of cables for a
cross section of 1.5 mm2 should not exceed 60 m; for a
cross section of 2.5 mm2, 100 m should not be exceeded.
16. Do not use the generator in the rain or snow.
17. Always turn off the engine when transporting or refuelling.
18. Fuel is combustible and highly flammable. Do fuel the unit
during operation. Do not fuel the unit when someone is
smoking or near open flames. Do not spill any fuel.
19. Do not refuel or empty near naked lights or flames or fly-
ing sparks. Do not smoke!
20. Put the generator on a secure and level place. Turning,
tipping or changing its position during operation is forbid-
den.
21. Install the generator at least 1 m away from the walls or
attached devices.
22. Children must be protected by ensuring that they stay a
safe distance away from the generator.
23. Some parts of the reciprocating internal combustion mo-
tor are hot and may cause burns. The warnings on the
generator must be observed.
24. Emission levels are represented in the technical data un-
der the stated values for sound power level (LWA) and
sound pressure level (LpA) and are not compulsory definite
working levels. Because there is a connection between
emission levels and immission levels, this can not reliably
used to determine the potentially necessary additional
precautions. Influencing factors on the workforce‘s cur-
rent immission level includes the properties of the work
area, other noise sources, air borne sound, etc. such as
e.g. the number of machines and other neighbouring pro-
cesses and intervals, to which the user is exposed. Also
the admissible immission levels can vary from country to
country. However, this information gives the user of the
machine the opportunity to have a better estimation of the
risks and dangers. Occasionally acoustic measurements
should be take after installation in order to determine the
sound pressure level.
25. Warning! Follow the electrical safety regulations that ap-
ply to the location where the generators are used.
26. Warning! Take into account the requirements and pre-
cautionary measures in the event of generators being re-
supplied, depending on the protective measures of this
device and the applicable directives.
27. Generator sets should only be used up to their rated out-
put under the rated ambient conditions. If the application
of the generating set is carried out under conditions which
do not comply with the reference conditions of ISO 8528-
10 (7.1), and if the cooling of the motor or generator is
impaired, e.g. as a result of operating in restricted areas,
a reduction in performance is required.
ATTENTION: Only use unleaded normal petrol as
fuel.
6. Technical data
Generator Inverter
Protection type IP23M
Continuous Power Pnenn (S1) 1000 W
Power Pmax (S2/5min) 1100 W
Power Pmax (S2/5s) 1200 W
Nominal voltage Unenn 230 V∼
Rated current Inenn 4,35 A
Frequency Fnenn 50 Hz
Type drive motor 4 stroke air-cooled
Engine displacement 54 cm³
Max. power (motor) 2.1 kW/2.85 PS
Fuel
Unleaded fuel
This device may not be
operated with E10 petrol
Tank capacity 4.2 l
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Parkside IAN 311314 PGI 1200 A1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Parkside IAN 311314 PGI 1200 A1 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 4,43 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info