748151
28
Verklein
Vergroot
Pagina terug
1/72
Pagina verder
21GB/IE
12. Cleaning, maintenance, and
storage
m Important!
Prior to any adjustment, maintenance or service work discon-
nect the mains power plug!
Cleaning
Keep all safety devices, air vents and the motor housing free
of dirt and dust as far as possible. Wipe the equipment with
a clean cloth or blow it with compressed air at low pressure.
We recommend that you clean the device immediately each
time you have finished using it.
Maintenance
There are no parts inside the equipment which require ad-
ditional maintenance.
Storage
Store the device and its accessories in a dark, dry and frost-
proof place that is inaccessible to children. The optimum stor-
age temperature is between 5 and 30˚C.
Store the power tool in original packaging.
Cover the electrical tool in order to protect it from dust and
moisture.
Store the operating manual with the electrical tool.
13. Disposal and recycling
The equipment is supplied in packaging to prevent it from be-
ing damaged in transit. The raw materials in this packaging
can be reused or recycled. The equipment and its accesso-
ries are made of various types of material, such as metal and
plastic. Defective components must be disposed of as special
waste. Ask your dealer or your local council.
The packaging is wholly composed of environment ally-
friendly materials that can be disposed of at a local recy-
cling centre.
Contact your local refuse disposal authority for more details
of how to dispose of your worn out electrical devices.
Old devices must not be disposed of with household waste!
This symbol indicates that this product must not be
disposed of together with domestic waste in compli-
ance with the Directive (2012/19/EU) pertaining to
waste electrical and electronic equipment (WEEE). This
product must be disposed of at a designated collection point.
This can occur, for example, by handing it in at an authorised
collecting point for the recycling of waste electrical and elec-
tronic equipment. Improper handling of waste equipment
may have negative consequences for the environment and
human health due to potentially hazardous substances that
are often contained in electrical and electronic equipment.
Press the workpiece firmly onto the saw bench (7) and
slowly slide into the Bandsaw blade (21).
In many cases it is helpful to roughly saw curves and cor-
ners approximately 6 mm from the line.
If it is necessary to saw curves that are too tight for the saw
band used, auxiliary cuts must be sawn up to the front face
of the curve, so that these fall off as wood waste when the
final radius is sawn.
11. Electrical connection
The electrical motor installed is connected and ready for op-
eration. The connection complies with the applicable VDE
and DIN provisions.
The customer‘s mains connection as well as the extension ca-
ble used must also comply with these regulations.
Important information
In the event of an overloading the motor will switch itself off.
After a cool-down period (time varies) the motor can be
switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often dam-
aged.
This may have the following causes:
Passage points, where connection cables are passed
through windows or doors.
Kinks where the connection cable has been improperly
fastened or routed.
Places where the connection cables have been cut due to
being driven over.
Insulation damage due to being ripped out of the wall
outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be
used and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regu-
larly. Make sure that the connection cable does not hang on
the power network during the inspection.
Electrical connection cables must comply with the applicable
VDE and DIN provisions. Only use connection cables with
the marking „H05VV-F“.
The printing of the type designation on the connection cable
is mandatory.
AC motor
The mains voltage must be 220 - 240 V~ 50 Hz.
Extension cables up to 25 m long must have a cross-sec-
tion of 1.5 mm
2
.
Connections and repairs of electrical equipment may only
be carried out by an electrician.
Please provide the following information in the event of any
enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
28

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Parkside IAN 303408 PBS 350 A1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Parkside IAN 303408 PBS 350 A1 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 3,05 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info