668497
43
Verklein
Vergroot
Pagina terug
1/51
Pagina verder
ERRORS shown b
y
SENSOR CONTROL BOARD (SCB) 22-aug-11
Display description problem Where to look / what to do
" " (nothing) = PCB standbymode/ sleepmode
1 All OK, ready to run Read softwareversion of all system
E25 No response main drive. (via CAN) Check Flatcable / Replace Main Board press lowest button on SCB
E26 Fail Safetyline test Main board Replace Main Board
Display will show 'd…L…C'
E30 No response level board. (via CAN) Check Flatcable / Replace Level Board
d… = version mainboard (drive)
E31 Fail Safetyline test Level board Replace Level Board
L… = version Leveldrive
E32 Fail Selftest Level board. Critical switch safetyline / Replace Level Board
C…= version sensor Control board
E33 * Overload LevelPCB / Levelmotor Long time high load. Continues heavy load out middle of outputshaft / Replace Level Board
E34 *
High / low supply voltage
{In software before version L27, this was only high supply voltage}
voltage fault on Level or Main board (Main board should respond earlier)
E35 Locked rotor / encoder fault Level motor Check wiring encoder / motor / Replace Level Board
E36 Motor direction error Critical switch safetyline / Check connection Level Motor
E37 Gate supply voltage missing, SLA and/or SLB not active (Tilt sensor?) Critical switch safetyline / Replace Level Board Calibrate chair and liftsensor
E38 *
High impuls current (overcurrent) {In softw. before version L27,this was low supply volt error}
Blocking of motor / Check wiring encoder Adjust seat horizontal. (by handwind)
press both buttons on SCB
E40 PCB error Sensor control Board Replace Sensor Control Board => calibate sensors after replacement display will show blinking 'h'
E41 Liftsensor Fault 1 (ADC) Replace Sensor Control Board => calibate sensors after replacement Hold buttons until blinking 'h' stops.
E42 Liftsensor Fault 2 (V) Replace Sensor Control Board => calibate sensors after replacement When 'h' is continue visible release buttons
E43
Liftsensor Fault 3 ()
Replace Sensor Control Board => calibate sensors after replacement Sensors are calibrated.
E44 Checksum error (Configs) Replace Sensor Control Board => calibate sensors after replacement
E45 System never has been calibrated. (factory default) Calibrate sensors
E50 Chairsensor outside range -3,5 or +3,5 degrees First check and set angle of Chairframe, do restart, and read 'new' error / or sensor not correctly calibrated
E51 Chairsensor Fault 1 (ADC) Replace Chairsensor => calibate sensors after replacement / check wiring Tiltsensor
E52 Chairsensor Fault 2 (V gyro) Replace Chairsensor => calibate sensors after replacement Set dynamic
E53
Chairsensor Fault 3 (V x/y) Replace Chairsensor => calibate sensors after replacement push highest button.
E54
Chairsensor Fault 4 ()
Replace Chairsensor => calibate sensors after replacement / check encodercable/connector While pressing highest button, press lowest
button 3 times.
(Then release highest button)
E60
Tilt sensor activated (outside -5 or +5deg )
Dual Safety line A (SLA) and B (SLB) not intact.
Tiltsensor activated / Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt Dot OFF at display is normal dynamics
E61 Dual Safety line A (SLA) not intact. Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt Dot ON is lower dynamic
E62 Dual Safety line B (SLB) not intact. Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt
E63
Fault in test Dualsafety-line (Given when fault is not E26/E31/E60/E61 or E62) [ NOTE * = no fast beep ]
ERRORS shown b
y
LEVEL BOARD
LED's description problem
LED 1 (YELLOW) Shows CPU status 0,5 Hz = OK / OFF = PCB not ON / ON = error
LED 2 (RED) Shows Status Dual Safetyline (output filter)
OFF Safety line filter A & B on
5Hz Safety line filter A off , B on
5Hz
1sON/1sOFF
Safety line filter A on , B off
ON Safety line filer A & B off
LED 3 (GREEN)
OFF / 0,5 Hz OK Motor control not active = off / Motor control active = 0,5 Hz
ON
Low / High supply voltage error / Motor direction error / Fail Selftest Level drive / Gate supply voltage missing (SCB for detail info)
5Hz 1sON/1sOFF
Locked rotor / encoder fault Level motor
5Hz Overcurrent/ Overload Level motor
43

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Otolift-One

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Otolift One bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Otolift One in de taal/talen: Engels als bijlage per email.

De handleiding is 4,36 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.