NOTE
Heat index is only calculated when temperature is 80° F / 27°C or above.
To view wind chill:
Press area repeatedly until WIND CHILL displays.
SUNRISE / SUNSET
NOTE
Make sure you input latitude and longitude of your location in area,
which affects the sunrise/sunset time.
NOTE
Excepting the latitude and longitude, daylight saving time setting also affects
sunrise and sunset (See Manually Set Clock).
You can view the sunrise or sunset time in
area.
Press SUNRISE/SUNSET area. displays on the top of the time display.
Press to change the time display between 12hr/24hr format.
WIND
DIRECTION CALIBRATION
Before pairing a wind sensor, make sure the head of the wind vane of that sensor
point to the north while pressing KEY for 2 seconds in the transmitter box to calibrate
the direction. If the calibration is successful, red light flashes once. You can use a
compass to look for an accurate direction of north if necessary.
However, if you are the user in North America, there are already 15°(degree)
variations existing between the true north and a compass reading of north. You
can consult your local observatory about this issue.
If it is difficult to control the wind vane after installation, you can calibrate through
setting on main unit.
1. Make a compass approach to the wind vane.
2. Calculate the angle between the current direction
and the north direction.
3. Press
wind area to activate.
4. Press and hold
, and then
press or to calibrate
the angle value.
5. Press
again to confirm setting.
For example, inputting the angle value that you
want to set as north. If current direction is 25
degree and you want to set it as north, then you
input 25 degree in the calibration mode. Once
you return to the idol mode, the direction reading
displays 0 degree, which is the north.
NOTE
You need to calibrate the wind sensor again if you want to relocate the sensor.
WIND SPEED / DIRECTION
To select wind display mode:
Press wind area to toggle between:
GUST (Gust)
AVG (Average)
To select wind speed unit:
Press to switch among:
Knots (knots)
Kilometres per hour (km/h)
Miles per hour (mph)
Metres per seconds (m/s)
The wind level is shown by a series of text icons:
LIGHT MODERATE STRONG STORM
2-8 mph
(3-13 km/h)
9-25 mph
(14-41 km/h)
26-54 mph
(42-87 km/h)
>55 mph
(>88 km/h)
To read the wind direction:
Status Wind Direction Indicator Meaning
GUST
Real-time wind direction
AVG
Real-time average wind direction
AVG
(Max 6 sets)
Wind direction of last 1 hour
RESET KEY
North
NOTE
The wind chill factor is based on the combined effects of temperature and
wind speed. Displayed wind chill is calculated solely from channel 1 thermometer
and humidity sensor.
BAROMETRIC PRESSURE
The altitude reflects distance from sea level at your position.
To set the altitude level compensation for the barometric readings:
1. Press
area to activate. displays next to the area and the tool bar
displays at the below of the screen.
2. Press the area until ALT displays on the screen. You are in altitude mode.
3. Press and hold
on the tool bar.
4. Press
or to edit. You can press to change the
altitude unit between M (Meter) and FEET (Feet) while editing.
5. Press
to confirm or touch panel area (except tool bar/barometer
area) to confirm.
6. After setting altitude, the new altitude setting will not be effective immediately.
The ALT icon flashes and stops flashing until the next pressure sampling. The
new altitude setting takes effect on the new pressure sampling.
NOTE
When altitude is set to 0 meter, the pressure reading is the local pressure.
If the altitude is set to the current location, the new pressure reading is an offset
pressure to the sea level.
To select the measurement unit for the barometer:
1. Press
barometer area to toggle between altitude and current barometer.
2. Press
to select inHg (inches of mercury) / mmHg (millimetres of
mercury) / mb (millibars per hectopascal) / hPa.
To view pressure trend:
The barometric pressure trend icons are based on recent sensor readings.
The trend lines are shown next to the pressure readings. The trend is shown
as follows:
Rising Steady Falling
RAINFALL
To select rainfall display mode:
Press rain area to toggle between:
THIS HOUR (Hourly rainfall)
RATE (Rain rate)
ACCUM (Accumulated rainfall)
PAST 24 hrs (Rainfall recorded in the past 24 hours)
To select the measurement unit for the rainfall:
Press to select between mm (millimeter) and in (inch).
To select the measurement unit for the rainfall rate:
Press to select between in/hr (inch per hour) and mm/hr (millimeter
per hour).
ACCUMULATED RAINFALL
To display accumulated rainfall:
Press rain area repeatedly until ACCUM display. (SINCE displays in the
clock area that displays the start date / time of rainfall recording simultaneously).
To reset SINCE time:
Press and hold
MEM to set current time as start of accumulated rainfall records.
The rainfall record is cleared and reset to 0.
BAR CHART
The bar chart simultaneously displays the data while you press on the
corresponding area.
To select chart display mode:
Press on the below areas to toggle among these chart displays.
IN TEMP (Indoor temperature)
IN HUM (Indoor humidity)
OUT TEMP (Outdoor temperature)
OUT HUM (Outdoor humidity)
DEWPOINT (Dew point)
HEAT INDEX (Heat index)
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Oregon Scientific WMR300A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Oregon Scientific WMR300A in de taal/talen: Engels als bijlage per email.

De handleiding is 10,75 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info