622897
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
Wireless Weather Station with
Temperature / Humidity Display and
Self - Setting Atomic Clock
MODEL: BAR688HGA
INTRODUCTION
Thank you for selecting this Oregon Scientic
TM
Wireless
Weather Station with Temperature / Humidity Display and
Self - Setting Atomic Clock (BAR688HGA). This clock
is supplied with a remote sensor (THGR122N) and can
support up to 3 sensors in total (additional sensors sold
separately).
NOTE Please keep this manual handy as you use your new
product. It contains practical step-by-step instructions, as
well as technical specications and warnings you should
know about.
CLOCK OVERVIEW
FRONT VIEW
1. SNOOZE
2. Weather Forecast Area
3. Outdoor Temperature Area
4. Indoor Temperature Area
5. Clock / Alarm Area
BACK VIEW
1. TEMP / HUMIDITY HI / LO : Change settings or
enable / disable hi or lo temperature / humidity alarm
for channel 1
2. / : Increase / decrease setting; activate / deactivate
clock reception signal
LCD DISPLAY
Weather Forecast Area:
Outdoor Temperature Area:
1. Heat index icon
2. Hi / lo temperature alarm
3. Sensor reception icon
4. Sensor battery low
5. Max / min icon
6. Temperature display
7. Ice warning is active
8. Hi / lo humidity alarm
9. Temperature trend
10. Humidity trend
11. Humidity display

Indoor Temperature Area:
1. Internal sensor icon
2. Max / min icon
3. Temperature display
4. Temperature trend
5. Humidity trend
6. Humidity display
Clock / Alarm Area:
1. Alarm set
2. AM / PM icon
3. Clock signal reception
4. Low battery icon
5. Clock
6. Alarm mode icon
7. Moon phase
REMOTE SENSOR (THGR122N)
1. LED status indicator:
Blinks red during data
transmission
2. LCD screen
1. Wall mount hole
2. RESET hole
3. CHANNEL switch
4. Battery compartment
GETTING STARTED
SETTING UP THE CLOCK
Insert batteries before rst use, matching the polarity (+
and -). RESET after each battery change.
SENSOR DATA TRANSMISSION
indicates main unit batteries are low.
NOTE Do not use rechargeable batteries. We
recommend that you use alkaline batteries with this product
for longer usage and lithium batteries in temperatures
below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every
40 seconds and sends them to the main unit. The main
unit can collect data from up to 3 sensors.
To set up the sensor:
1. Remove the screws from the battery door.
2. Insert the batteries, matching the polarity (+ / -).
3. Select a channel. Make sure you use a different channel
for each sensor.
4. Place the sensor near the main unit. Press RESET on
the sensor.
5. Simultaneously press CHANNEL and MEM on the main
unit to initiate signal sending between the sensor and
main unit.
6. Close the battery door and secure the screws
7. Place the sensor in the desired location using the table
stand or wall mount.
For best results:
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 m (100 ft) from
the main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls, and
furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
Data is sent from the sensor(s) every 40 seconds. The
sensor reception icon in the remote sensor area shows
the status.
ICON DESCRIPTION
and “- - . -“
(Outdoor
temperature area)
The sensor cannot be found.
Search for the sensor or check
batteries
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for
2 seconds.
NOTE If the sensor is still not found, check the batteries,
obstructions, and remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time
automatically once it is within range of the WWVB-60 signal
from the atomic clock in Boulder, Colorado.
The sensor collects the radio signals whenever it is within
1500 km (932 miles) of a signal.
NOTE Initial reception takes 2-10 minutes for rst set up
or when RESET is pressed. Once complete, the reception
icon will stop blinking. If the signal is weak, it can take up
to 24 hours to get a valid signal.
RECEPTION SIGNAL
To enable and force a signal search:
Press and hold for 2 seconds.
To disable the signal reception:
Press and hold for 2 seconds.
ashes when it is disabled.
STRONG SIGNAL WEAK SIGNAL NO SIGNAL
SET CLOCK
To manually set the clock make sure the clock signal
reception is disabled.
1. Press and hold MODE for 2 seconds.
2. Select the US time zone (Pacic (P), Eastern (E),
Central (C) and Mountain (M)), hour, minute, year,
month, day and language. Press or to change the
setting.
3. Press MODE to conrm.
NOTE The language options are English (E), German (D),
French (F), Italian (I), and Spanish (S).
Press MODE to choose between the clock with seconds
and clock with weekday display modes.
1. Pressure trend
2. Weather forecast
3. Comfort zone
4. Pressure icon
5. Altitude icon
6. Pressure / Altitude unit
7. UV index icon
USER MANUAL
3. CHANNEL: Switch remote sensor display
4. HEAT INDEX: Display heat index
5. MODE: Change settings / display
6. ALARM: View alarm status; set alarm
7. Battery compartment
8. MEM: View current, maximum and minimum
temperature / humidity
9. PRESSURE: Select pressure unit; set altitude
10. °C / °F: Select temperature unit
11. RESET: Reset unit to default settings
The transmission range may vary depending on many
factors. You may need to experiment with various locations
to get the best results.
Standard Alkaline batteries contain signicant amounts of
water. Because of this they will freeze in low temperatures
of approximately -12°C (10°F). Disposable Lithium
batteries have a much lower threshold for temperature
with an estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold may
temporarily reduce the effective range between the sensor
and the base station. If the unit's performance fails due to
low temperature, the unit will resume proper functioning
as the temperature rises to within the normal temperature
range (i.e. no permanent damage will occur to the unit due
to low temperatures).
Sensor 1 is sending data
A channel has been found
Main unit is searching
for the sensor(s)
Clock signal reception indicator:
BAR688HGA_M 2005.12.12, 4:06 PM1
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Oregon Scientific BAR688HGA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Oregon Scientific BAR688HGA in de taal/talen: Engels als bijlage per email.

De handleiding is 0,85 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info