585399
2
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
EN
Artisan Weather Station
Model: BAR220 / BAR220A /
BAR220U
USER MANUAL
OVERVIEW
FRONT VIEW
1
2 3
4
5
6
7
8
9
1. Weather forecast icons
2. ZONE: time zone offset
3.
: main unit batteries low / no battery
4. MODE: toggle between time / indoor temperature /
outdoor temperature displays
5.
: signal reception indicator
6. PM: indicate PM
7. Clock / indoor temperature / outdoor temperature
8. IN: indoor temperature is displayed
9. : remote sensor reception indicator / outdoor
temperature is displayed
REAR VIEW
1
2
3
4
5
6
7
8
1. : set clock
2.
/ : increase / decrease value of the selected
setting; enable / disable clock reception signal
3. ˚C / ˚F: select temperature units; display temperature
4. RESET: Reset unit to default settings
5. DIMMER HI·LO: select display brightness
6. AUTO ON/OFF/DEMO: activate / deactivate colour-
dance effect; select pre-programmed colour-dance
demo
7. Battery compartment
8. AC adaptor socket / temperature sensor
REMOTE SENSOR
1
2
3
4
5
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
5. Channel switch
GETTING STARTED
POWER SUPPLY
Batteries serve as a back-up power supply. For continuous
use of weather icon colour effect and backlight, adaptor must
be installed.
1 adaptor
Use the adaptor supplied to power the unit.
Make sure the adaptor is not obstructed and is easily
accessible to the unit.
NOTE The main unit and adaptor should not be exposed to
wet conditions. No objects filled with liquid, such as vases,
should be placed on the main unit and adaptor.
To completely disconnect from power, unplug adaptor from
the mains.
2 CR2032 batteries for memory backup
To insert batteries:
1. Remove the battery compartment cover.
2. Insert the batteries, matching the polarities (+/ -).
3. Press RESET after each battery change.
MEANING
Battery is low in power
No battery installed – only AC adaptor
SET UP REMOTE SENSOR
The main unit can be connected to only 1 remote sensor.
1. Slide open the battery door.
2. Insert battery, matching the polarities (+ / -).
3. Select channel then press RESET.
4. Close the battery door.
NOTE Use alkaline batteries for longer usage and consumer
grade lithium batteries in temperatures below freezing.
DATA TRANSMISSION
SENSOR
The main unit will automatically search for sensor.
To search for a sensor manually:
Press and hold
+ together.
For best results:
Place the sensor within 30 m (100 ft) of the main unit.
Position the sensor so that it faces the main unit,
minimizing obstructions such as doors, walls and
furniture.
Place the sensor out of direct sunlight and moisture.
Place the sensor in a location with a clear view to the
sky, away from metallic / electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
The remote sensor reception icon will show the
following status:
ICON DESCRIPTION
Main unit is searching
for sensor(s).
A channel has been
found.
The sensor cannot be
found.
NOTE The main unit will search only for already registered
sensor or new sensor reset within the last 30 minutes. If unit
failed to synchronise with remote sensor, reset the sensor or
try selecting a different channel (and press RESET) before
manually forcing another search.
TIP The transmission range may vary depending on many
factors. You may need to experiment with various locations
to get the best results.
CLOCK
CLOCK RECEPTION
This product is designed to synchronise its clock automatically
with a clock signal.
BAR220:
EU: DCF-77 signal: within 1500 km (932 miles) of
Frankfurt, Germany.
BAR220A:
US: WWVB-60 signal: within 3200km (2000 miles) of
Fort Collins Colorado.
BAR220U:
UK: MSF-60 signal: within 1500 km (932 miles) of
Anthorn, England.
To enable / disable signal reception:
Press and hold
to enable or to disable signal
reception.
NOTE Reception takes 2-10 minutes. If the signal is weak,
it can take up to 24 hours to get a valid signal.
Clock signal reception indicator:
MEANING
Continuous Strong signal
Flashes No signal
NOTE The unit searches for a clock signal everyday at
01:00, 02:00 and 03:00, as well as 3 minutes after switching
on or resetting unit. During signal search:
1) display (i.e., time and temperature) will be turned off
temporarily
2) only flashing
will be displayed
3) weather icon will remain lit however the colour will be
static.
Signal search may take approx. 10 minutes and display will
resume thereafter. To view display temporarily during signal
search, press any key.
If signal reception is unsuccessful, place your unit next to a
window, press and hold
to force another signal search.
MANUALLY SET CLOCK
To set the clock manually, disable the clock signal reception
first.
1. Press and hold to enter.
2. Press
or to increase / decrease values of the
selected setting.
3. Press to confirm.
The settings order is: time zone offset, 12/24 hr format, hour,
minute.
Time zone offset sets the clock +/- 23 hours from the received
clock signal time. If you have deactivated the clock signal
reception, do not set a value for time zone.
NOTE If you enter +1 in the time zone setting, this will give
you your regional time plus 1 hour.
If you are in the US (BAR220A only) set the clock to:
0 for Pacific time +1 for Mountain time
+2 for Central time +3 for Eastern time
CHANGE DISPLAY
To activate / deactivate display auto-toggle function:
Slide TOGGLE switch to ON/OFF.
In auto-toggle mode, display will alternate between time,
indoor temperature and outdoor temperature.
To play demo colour-dance:
Slide TOGGLE switch to DEMO.
Both the weather icons and the time / temperature displays
will auto-toggle.
IMPORTANT The colour-dance is only for aesthetic
reasons. The weather icons will be displayed in a loop
sequence, therefore, the displayed icons have no bearing on
actual weather conditions.
To manually toggle display:
Press
OR
Touch MODE.
To change display brightness:
Slide DIMMER switch to HI / LO.
NOTE Auto toggle mode will be disabled if a button is
pressed, but will be enabled again if no button is pressed
for 5 seconds.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather
forecast within a 30-50 km (19-31 mile) radius.
Weather Forecast Area
ICON MEANING
Sunny
Cloudy
Rainy
TEMPERATURE
To display temperature or select temperature unit:
Press ˚C / ˚F.
NOTE Please keep the temperature sensor (adjacent to the
adaptor socket) away from electrical devices as heat from
these devices will affect the accuracy of indoor temperature
readings.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
Do not cover the ventilation holes with any items such as
newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components. This
invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the actual
display.
When disposing of this product, ensure it is collected
separately for special treatment and not as normal
household waste.
Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before first use.
NOTE The technical specifications for this product and the
contents of the user manual are subject to change without
notice.
NOTE Features and accessories will not be available in all
countries. For more information, please contact your local
retailer.
SPECIFICATIONS
MAIN UNIT
TYPE DESCRIPTION
Dimensions
L x W x H
100 x 195 x 70 mm
(3.9 x 7.7 x 2.8 in)
Weight
296 g (10.4 oz) without
battery
Temperature range
-5°C to 50°C
(23°F to 122°F)
Power
AC/DC 6V adaptor
2 x CR2032 batteries (for
back-up)
REMOTE THERMO SENSOR (THN132N)
TYPE DESCRIPTION
Dimensions
L x W x H
50 x 23 x 95 mm
(1.97 x 0.9 x 3.74 in)
Weight
50 g (1.76 oz) without
battery
Temperature range
-20°C to 60°C
(-4°F to 140°F)
Signal frequency 433 MHz
Transmission range 30 m (100 ft) unobstructed
Transmission period
Approximately every 60
seconds
Number of channels 3
Power 1 x UM-3 (AA) 1.5V battery
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products.
If you're in the US and would like to contact our Customer
Care department directly, please visit: www2.oregonscientific.
com/service/support.asp
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Artisan
weather station (model: BAR220 / BAR220A / BAR220U)
is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. A copy of the
signed and dated Declaration of Conformity is available on
request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries,Switzerland CH
and Norway N
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Oregon Scientific BAR220A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Oregon Scientific BAR220A in de taal/talen: Engels als bijlage per email.

De handleiding is 3,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info