504882
3
Verklein
Vergroot
Pagina terug
1/26
Pagina verder
HEM-4030-E_A_M08_090605.pdf
Check following components!
Vérifier les composants suivants !
Prüfen Sie folgende Teile des Lieferumfangs!
Проверьте следующие компоненты!
Controllare i componenti indicati di seguito!
Należy upewnić się, że zestaw zawiera
wszystkie poniższe elementy!
¡Compruebe los siguientes componentes!
Ellenőrizze a következő alkatrészeket!
!ﺔﻴﻟﺎﺘﻟﺍ ﺕﺎﻧﻮﻜﻤﻟﺍ ﻦﻣ ﻖﻘﺤﺗ
Controleer de volgende onderdelen!
Manufacturer
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto,
617-0002 JAPAN
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS
www.omron-healthcare.com
Production facility
Productiefaciliteit
Site de production Производственное подразделение
Produktionsstätte
Siedziba produkcji
Stabilimento di produzione
Termékképviselet
Oficina de producción ﺝﺎﺘﻧﻹﺍ ﻊﻨﺼﻣ
OMRON (DALIAN) CO., LTD.
Dalian, CHINA
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K.
Subsidiary
Dochteronderneming
Succursale
Дочерняя компания
Niederlassung
Filia
Consociata
Leányvállalat
Empresa filial ﺔﻌﺑﺎﺘﻟﺎﻛﺮﺸﻟ
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a, 68163 Mannheim, GERMANY
www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE
Uniquement pour le marché français:
OMRON Service Après Vente
Nº Vert 0 800 91 43 14
consommateurs@omron-sante.fr
www.omron-sante.fr/contact
Fabricado en China ﻦﻴﺼﻟﺍ ﻲﻓ ﻊﻨ
ُ
Származási ország: Kína
Prodotto in Cina
Wyprodukowano w Chinach
Hergestellt in China
Сделано в КитаеFabriqué en Chine
Geproduceerd in ChinaMade in China
Manual Inflation Blood Pressure Monitor
Model M1
Instruction Manual
Deutsch
Italiano
Español
Nederlands
Русский
Polski
Magyar
IM-HEM-4030-E-02-10/2011
5325678-8D
English
Français
Manual Inflation Blood Pressure Monitor
Model M1
Instruction Manual
Deutsch
Italiano
Espanõl
Nederlands
Polski
Magyar
IM-HEM-4030-E-01-10/09
5325678-8A
English
Français
c
d
21
M
L
K
GF
HA
J
I
B
S
R
P
N
Q
C
E
D
O
HEM-4030-E_en_TOC.fm Page 14 Tuesday, May 19, 2009 3:02 PM
a
b
Contents
Thank you for purchasing the OMRON M1 Manual Inflation Blood Pressure Monitor.
The OMRON M1 is a compact manual inflation blood pressure monitor, operating on the oscillometric
principle. It measures your blood pressure and pulse rate simply and quickly.
Important Safety Information.................................1
1. Overview ..........................................................................3
2. Preparation......................................................................4
2.1 Installing/Replacing the Batteries ................ 4
3. Using the Unit..................................................................5
3.1 Applying the Arm Cuff.................................. 5
3.2 How to Sit Correctly..................................... 6
3.3 Taking a Reading ........................................ 7
3.4 Using the Memory Function....................... 10
4. Troubleshooting and Maintenance..........................12
4.1 The Icons and Error Messages ................. 12
4.2 Troubleshooting......................................... 14
4.3 Maintenance.............................................. 16
4.4 Storage...................................................... 17
5. Optional Parts...............................................................18
6. Technical Data..............................................................19
7. Some Useful Information about Blood Pressure.22
Please read this instruction manual thoroughly before using the unit.
Please keep for future reference.
For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
1
EN
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis.
Please read this section carefully before using the unit.
Warning:
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
(General Usage)
Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous.
People with severe blood flow problems, or blood disorders, should consult a doctor before using the
unit, as cuff inflation can cause internal bleeding.
(Battery Usage)
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor
immediately.
Caution:
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury to the user or patient or damage to the equipment or other property.
(General Usage)
Do not leave the unit unattended with infants or persons who cannot express their consent.
Do not use the unit for any purpose other than measuring blood pressure.
Do not disassemble the unit or arm cuff.
Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect
measurement results.
Make sure that the air tube is not wrapped around other parts of your body when taking
measurements at night. This could result in injury when the air pressure in the air tube is increased.
Do not leave the cuff wrapped on the arm if taking measurements during the night. This could result in
injury.
HEM-4030-E_A_M_all.book 1 ページ 2011年11月18日 金曜日 午後4時50分
2
Important Safety Information
Do not inflate the arm cuff over 299 mmHg.
Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may
result in incorrect operation of the unit.
Do not operate the unit in a moving vehicle (car, airplane).
(Battery Usage)
If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
Use only two “AAA” alkaline or manganese batteries with this unit. Do not use other types of batteries.
Do not insert the batteries with their polarities incorrectly aligned.
Replace old batteries with new ones immediately. Replace both batteries at the same time.
Remove the batteries if the unit will not be used for three months or more.
Do not use new and used batteries together.
General Precautions
Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
Do not take measurements after bathing, drinking alcohol, smoking, exercising or eating.
Do not forcibly bend the arm cuff or bend the air tube excessively.
When removing the air tube, pull the air tube with holding near the air jack.
Do not inflate the arm cuff when it is not wrapped around your arm.
Do not wash the arm cuff or immerse it in water.
Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the
Technical Data Section.
Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing
of the device and any used accessories or optional parts.
HEM-4030-E_A_M_all.book 2 ページ 2011年11月18日 金曜日 午後4時50分
3
EN
1. Overview
Main unit
Display
M (Memory) button
I/O (Power switch) button
Air jacks for cuff and inflation bulb
Battery compartment
Arm cuff
Arm cuff
(Medium cuff: arm
circumference 22-32 cm)
Air tube
Inflation bulb
Air release button
Air tube
Air inflation bulb
Display
Systolic blood pressure
Diastolic blood pressure
Pulse display
Memory No. symbol
Deflation symbol
Heartbeat symbol
1. Flashes during measurement
2. If flashing after measurement complete
indicates blood pressure out of recommended
range
Reinflation symbol
Battery low symbol
Memory symbol
Open the rear cover page to read following:
The alphabet in the rear cover page correspond to those in the body page.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
HEM-4030-E_A_M_all.book 3 ページ 2011年11月18日 金曜日 午後4時50分
4
2. Preparation
2.1
Installing/Replacing the Batteries
1. Remove the battery cover.
2. Insert two “AAA” batteries
as indicated in the battery
compartment and then
replace the battery cover.
Notes:
If the battery low symbol ( ) appears on
the display, turn the unit off then replace
both batteries at the same time.
The measurement values continue to be stored in memory even after the batteries are replaced.
Disposal of used batteries should be carried out in accordance with the national regulations for the
disposal of batteries.
HEM-4030-E_A_M_all.book 4 ページ 2011年11月18日 金曜日 午後4時50分
5
EN
3. Using the Unit
3.1
Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your upper arm.
Do not place the cuff over thick clothes.
1. Insert the air tubes into the air jacks.
2. Put your arm through the cuff loop.
3. Position the arm correctly.
The bottom edge of the cuff should be 1 to 2 cm above the elbow. Marker (arrow under
tube) is centred on the middle of your inner arm. Close the fabric fastener FIRMLY.
Notes:
When you take a measurement on the right arm, air tube will be at the side of your elbow. Be
careful not to rest your arm on the air tube. ---
The blood pressure can differ between the right arm and the left arm, and therefore also the
measured blood pressure values can be different. Omron recommends to always use the same
arm for measurement. If the values between the two arms differ substantially, please check with
your physician which arm to use for your measurement.
Open both the front and rear covers to read following:
The alphabet and number in the cover page correspond to those in the body page.
G
I
D
HEM-4030-E_A_M_all.book 5 ページ 2011年11月18日 金曜日 午後4時50分
6
3. Using the Unit
3.2
How to Sit Correctly
To take a measurement, you need to be relaxed and comfortably seated, under comfortable room
temperature. No eating, smoking or exercising 30 minutes before taking a measurement.
Sit on a chair with your feet flat on the floor.
Sit upright with your back straight. ---
The cuff should be at the same level as your heart. ---
HEM-4030-E_A_M_all.book 6 ページ 2011年11月18日 金曜日 午後4時50分
7
3. Using the Unit
EN
3.3
Taking a Reading
Note:
Remain still while taking measurement.
1. Press the air release button to release any air in the arm cuff,
then press the I/O button to turn the unit on.
Note:
If the deflation symbol does not disappear soon, press the air release button to release any air in the arm cuff.
2. Pump the inflation bulb to inflate the arm cuff.
1) Inflate the cuff until it is 30 to 40 mmHg above your expected
systolic blood pressure value.
ex) If your expected blood pressure is around 140mmHg, inflate the arm
cuff to between 170 and 180 mmHg. Inflate the cuff rapidly so that the
pressure is reached in about five seconds.
2) When the desired pressure has been achieved, release the inflation bulb.
Notes:
If the reinflation symbol ( ) appears, squeeze the inflation bulb to re-inflate the arm cuff.
Do not inflate the arm cuff more than necessary.
HEM-4030-E_A_M_all.book 7 ページ 2011年11月18日 金曜日 午後4時50分
8
3. Using the Unit
3. Measurement starts.
Measurement starts automatically after you stop inflating the arm cuff.
Notes:
To cancel a measurement, press the I/O button to turn off the unit and press the air release
button to release the air in the arm cuff.
Wait 2-3 minutes before taking another blood pressure measurement. Waiting between
readings allows the arteries to return to the condition prior to taking the blood pressure
measurement.
Warning:
Self-diagnosis of measured results and treatment are dangerous. Please follow the
instructions of your doctor.
START
DEFLATE
END
COMPLETE
Press the air release button
to release the air in the arm
cuff until the deflation symbol
is no longer displayed.
HEM-4030-E_A_M_all.book 8 ページ 2011年11月18日 金曜日 午後4時50分
9
3. Using the Unit
EN
4. Remove the arm cuff.
5. Press the I/O button to turn off the monitor.
The monitor automatically stores the measurement in its memory.
It will automatically turn off after five minutes.
Important:
If your systolic or diastolic pressure is outside the standard range, the
heartbeat symbol will blink when the measurement result is displayed.
Recent research suggests that the following values can be used as a
guide to high blood pressure for measurements taken at home.
This criteria is for home blood pressure measurement.
For professional office blood pressure measurement criteria, please refer to Chapter 7.
Systolic Blood Pressure Above 135 mmHg
Diastolic Blood Pressure Above 85 mmHg
HEM-4030-E_A_M_all.book 9 ページ 2011年11月18日 金曜日 午後4時50分
10
3. Using the Unit
3.4
Using the Memory Function
The monitor automatically stores the result up to 14 sets.
Note:
If the memory is full, the monitor will delete the oldest readings.
Previous Reading
Turn the Unit on View Previous
Reading
The Memory number
appears for a second
before the pulse rate is
displayed. The newest
set is numbered “1”.
View Readings
Stored in Memory
Press repeatedly to
cycle through the
previous results.
Hold down to cycle
rapidly.
HEM-4030-E_A_M_all.book 10 ページ 2011年11月18日 金曜日 午後4時50分
11
3. Using the Unit
EN
To delete all the values stored in memory
When the memory symbol ( ) appears, first press the M button. Then while holding it down,
press the I/O button simultaneously for about 2-3 seconds.
Note:
You cannot partially delete the stored readings.
HEM-4030-E_A_M_all.book 11 ページ 2011年11月18日 金曜日 午後4時50分
12
4. Troubleshooting and Maintenance
4.1
The Icons and Error Messages
Error Display Cause Remedy
The systolic blood pressure is above
135 mmHg or diastolic blood pressure
is above 85 mmHg.
These criteria are for home blood pressure
measurement. For professional criteria,
please refer to Chapter 7.
The batteries are low.
You should replace them with new ones
ahead of time.
Refer to section 2.1.
The batteries are exhausted.
You should replace them with new ones at
once.
Refer to section 2.1.
Blink
Lit
HEM-4030-E_A_M_all.book 12 ページ 2011年11月18日 金曜日 午後4時50分
13
4. Troubleshooting and Maintenance
EN
Cuff is under inflated.
Carefully read and repeat the steps listed
under section 3.3.
Movement during measurement.
Cuff over inflated.
Device error.
Contact your OMRON retail outlet or
distributor.
Refer to Chapter 6.
Pressure is too low.
Press the inflation bulb to inflate the arm
cuff until the reinflation symbol goes out.
Or, deflate the arm cuff and repeat
measurement after checking that the
heartbeat symbol ( ) has been displayed.
Refer to section 3.3.
Error Display Cause Remedy
HEM-4030-E_A_M_all.book 13 ページ 2011年11月18日 金曜日 午後4時50分
14
4. Troubleshooting and Maintenance
4.2
Troubleshooting
Problem Cause Remedy
The reading is extremely low (or
high).
Arm cuff not applied correctly.
Apply the arm cuff correctly.
Refer to section 3.1.
Movement or talking during
measurement.
Remain still and do not talk
during measurement.
Refer to section 3.3.
Clothing is interfering with the
arm cuff.
Remove any clothing
interfering with the arm cuff.
Refer to section 3.2.
Arm cuff pressure does not rise.
The air tube is not securely
connected into the main unit.
Make sure that the air tube is
connected securely.
Refer to section 3.1.
Air is leaking from the arm cuff.
Replace the arm cuff with a
new one.
Refer to Chapter 5.
HEM-4030-E_A_M_all.book 14 ページ 2011年11月18日 金曜日 午後4時50分
15
4. Troubleshooting and Maintenance
EN
Cannot measure or readings are
too low or too high.
The arm cuff has not been
inflated sufficiently.
Inflate the cuff so that it is 30 to
40 mmHg above your previous
measurement result.
Refer to section 3.3.
The air release button being
pressed during inflation.
Be careful not to press the air
release button during
measurement.
The unit loses power during
measurement.
The batteries are empty.
Replace the batteries with new
ones.
Refer to section 2.1.
Nothing happens when you
press the buttons.
The batteries are empty.
Replace the batteries with new
ones.
Refer to section 2.1.
The batteries have been
inserted incorrectly.
Insert the batteries with the
correct (+/-) polarity.
Refer to section 2.1.
Other problems.
Press the I/O button and repeat measurement.
If the problem continues, try replacing the batteries with new
ones.
If this still does not solve the problem, contact your OMRON
retail outlet or distributor.
Problem Cause Remedy
HEM-4030-E_A_M_all.book 15 ページ 2011年11月18日 金曜日 午後4時50分
16
4. Troubleshooting and Maintenance
4.3
Maintenance
To protect your unit from damage, please observe the following:
Do not subject the main unit, cuff and inflation bulb to extreme temperatures, humidity, moisture or
direct sunlight.
Do not fold the cuff or tubing tightly.
Do not inflate the arm cuff over 299 mmHg.
Do not disassemble the unit.
Do not subject the unit to strong shocks or vibrations (for example, dropping the unit on the floor).
Do not use volatile liquids to clean the main unit. The unit should be cleaned with a soft, dry cloth.
Use a soft, moistened cloth and soap to clean the arm cuff.
Do not wash the arm cuff or immerse it in water.
Do not use petrol, thinners or similar solvents to clean the arm cuff.
Do not carry out repairs of any kind yourself. If a defect occurs, consult your OMRON retail outlet
or distributor as mentioned on the packaging.
Calibration and Service
The accuracy of this blood pressure monitor has been carefully tested and is designed for a long
service life.
It is generally recommended to have the unit inspected every two years to ensure correct
functioning and accuracy. Please consult your authorised OMRON dealer or the OMRON
Customer Service at the address given on the packaging or attached literature.
HEM-4030-E_A_M_all.book 16 ページ 2011年11月18日 金曜日 午後4時50分
17
4. Troubleshooting and Maintenance
EN
4.4
Storage
Keep the unit in its storage case when not in use.
Do not keep the main unit being wound with the arm cuff.
1. Unplug the air tubes from the air connector.
2. Gently fold the air tube into the arm cuff.
Note:
Do not bend the air tube excessively.
3. Place the arm cuff, inflation bulb and main
unit in the storage case.
Do not store the unit in the following situations:
If the unit is wet.
Locations exposed to extreme temperatures, humidity, direct
sunlight, dust or corrosive vapours.
Locations exposed to vibrations, shocks or where it will be at an angle.
HEM-4030-E_A_M_all.book 17 ページ 2011年11月18日 金曜日 午後4時50分
18
5. Optional Parts
Note:
Should you require a small cuff, please ensure that the small cuff and small bulb are used together.
They may also be purchased as a combination set.
Medium Arm Cuff
Arm circumference 22 - 32 cm
Large Arm Cuff
Arm circumference 32 - 42 cm
Small Arm Cuff
Arm circumference 17 - 22 cm
Small cuff and bulb combination
Arm circumference 17 - 22 cm
Regular bulb
CM2-9513256-6 (Model: HEM-CR24)
CM1-9997578-9
CL2-9513255-8 (Model: HEM-CL24)
CL1-9996760-3
CS-4997067-0
4997099-9
4997965-1
HEM-4030-E_A_M_all.book 18 ページ 2011年11月18日 金曜日 午後4時50分
19
EN
6. Technical Data
Product Description Manual Inflation Blood Pressure Monitor
Model OMRON M1 (HEM-4030-E)
Display LCD Digital Display
Measurement Method Oscillometric method
Measurement Range Pressure: 0 mmHg to 299 mmHg
Pulse: 40 to 180/min.
Accuracy Pressure: 3 mmHg
Pulse: 5% of display reading
Inflation Manual by inflation bulb
Deflation Automatic pressure release valve
Pressure Detection Capacitive pressure sensor
Memory 14 Measurements
Power Source 2 “AAA” batteries 1.5V
Battery Life Capacity of new manganese batteries is approx. 1500 measurements
Applied Part
Protection Against Electric
Shock
Internally powered ME equipment
Operating temperature/
Humidity
+10°C to +40°C / Maximum: 30 to 90% RH
Storage temperature/
Humidity/ Air pressure
-20°C to +60°C / Maximum: 10 to 95% RH / 700-1060 hPa
Console Weight Approximately 75g without batteries
Cuff Weight Approximately 120g
Outer Dimensions Approximately 64 (w) mm 35 (h) mm 105(I) mm
= Type B
= Type B
HEM-4030-E_A_M_all.book 19 ページ 2011年11月18日 金曜日 午後4時50分
20
6. Technical Data
Note:
Subject to technical modification without prior notice.
This device fulfils the provisions of EC directive 93/42/EEC (Medical Device Directive).
This blood pressure monitor is designed according to the European Standard EN1060, Non-invasive
sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for
electromechanical blood pressure measuring systems.
This OMRON product is produced under the strict quality system of OMRON Healthcare Co. Ltd.,
Japan. The Core component for OMRON blood pressure monitors, which is the Pressure Sensor, is
produced in Japan.
Cuff Dimensions Approximately 146 mm 446 mm
(Medium cuff: arm circumference 22 to 32 cm)
Cuff Material Nylon and polyester
Package Content Main unit, cuff, inflation bulb, instruction manual, storage case, battery
set, guarantee card, blood pressure pass
HEM-4030-E_A_M_all.book 20 ページ 2011年11月18日 金曜日 午後4時50分
21
6. Technical Data
EN
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in
use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result
in incorrect operation of the medical device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product
situations, the EN60601-1-2:2007 standard has been implemented. This standard defines the levels of immunity to
electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both
immunity and emissions.
Nevertheless, special precautions need to be observed:
Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic
fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe
situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the
distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON Healthcare Europe at the
address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com
.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be disposed of, with other
household wastes at the end of its working life. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local
government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This
product should not be mixed with other commercial wastes for disposal.
This product does not contain any hazardous substances.
HEM-4030-E_A_M_all.book 21 ページ 2011年11月18日 金曜日 午後4時50分
22
7.
Some Useful Information about Blood Pressure
What is Blood Pressure?
Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood
pressure is constantly changing during the course of the heart’s cycle.
The highest pressure in the cycle is called the Systolic Blood Pressure; the lowest is the Diastolic Blood
Pressure.
Both pressure readings, the Systolic and Diastolic, are necessary to enable a doctor to evaluate the
status of a patient’s blood pressure.
What is Arrhythmia?
Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio-electrical
system that drives the heartbeat. Typical symptoms are skipped heartbeats, premature contraction, an
abnormally rapid (tachycardia) or slow (bradycardia) pulse.
HEM-4030-E_A_M_all.book 22 ページ 2011年11月18日 金曜日 午後4時50分
23
7. Some Useful Information about Blood Pressure
EN
Why is it a Good Thing to measure Blood Pressure at Home?
Many factors such as physical
activity, anxiety, or the time of day,
can influence your blood pressure.
A single measurement may not be
sufficient for an accurate diagnosis.
Thus it is best to try and measure
your blood pressure at the same
time each day, to get an accurate
indication of any changes in blood
pressure. Blood pressure is typically
low in the morning and increases
from afternoon to evening. It is
lower in the summer and higher in
the winter.
Example: fluctuation within a day (male, 35 years old)
mmHg
200
150
100
50
61218 24
Upper curve: systolic blood pressure
Lower curve: diastolic blood pressure
Time of day
HEM-4030-E_A_M_all.book 23 ページ 2011年11月18日 金曜日 午後4時50分
24
7. Some Useful Information about Blood Pressure
Classification of Blood Pressure by the World Health Organization
The World Health Organization (WHO) and the
International Society of Hypertension (ISH) developed
the Blood Pressure Classification shown in this figure.
This classification is based on the blood pressure
values measured on people in a sitting position in
outpatient departments of hospitals.
Note:
There is no universally accepted definition of
hypotension. However, those having the systolic
pressure below 100 mmHg are assumed as
hypotensive.
80
180
160
140
130
120
85 90 100 110
Systolic blood pressure
(mmHg)
Severe hypertension
Moderate hypertension
Mild hypertension
Normal systolic value
Normal blood
pressure
Optimal blood
pressure
(target value)
Diastolic
blood
pressure
(mmHg)
HEM-4030-E_A_M_all.book 24 ページ 2011年11月18日 金曜日 午後4時50分
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Omron M1 - HEM-4030-E bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Omron M1 - HEM-4030-E in de taal/talen: Engels als bijlage per email.

De handleiding is 1,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Omron M1 - HEM-4030-E

Omron M1 - HEM-4030-E Gebruiksaanwijzing - Nederlands - 26 pagina's

Omron M1 - HEM-4030-E Gebruiksaanwijzing - Deutsch - 26 pagina's

Omron M1 - HEM-4030-E Gebruiksaanwijzing - Français - 26 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info