Introduction
Thank you for purchasing the OMRON
®
BP742N Blood Pressure Monitor .
Y our new blood pressure monitor uses the oscillo metric method of blood pressure
measurement. This means the monitor detects your blood movement through your
brachial artery and converts the movements into a digital reading. An oscillometric
monitor does not need a stethoscope so the monitor is simple to use.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and
pulse rate in adult patient population who can understand this instruction manual
with the arm circumference range printed on the ar m cuff. The device detects the
appearance of irregular heartbeats during measurement and gives a warning signal
with the measurement result.
Please read this instruction manual thor oughly before using the device.
Please keep for future reference. For specific information about your own blood
pressure, CONSUL T YOUR PHYSICIAN.
Import ant Safety Information
W arning: Indicates a pot entially hazardous situation which , if not avoided,
could result in death or seriou s injury .
(General Usage)
DO NOT adjust medication based on measurement r esults from this blood
pressure monitor . T ake medication as prescribe d by your physician. Only a
physician is qualified to diagnose and treat High Blood Pressure.
This device is not intended to be a d iagnostic device.
Consult your physician before using the device in pr egnancy including
pre-eclampsia, or if diagnosed with arrhythmia or arteriosclero sis.
Do not use the device on the injured arm or the arm under medical treatment.
Do not apply the arm cuff on the arm while being on an intravenous drip or b lood
transfusion.
Consult your physician before using the device on the arm with an arterio-venous
(A-V) shunt.
Do not use the device with other medical electrical (ME) e quipment
simultaneously .
Do not use the device in the area the HF surgical equipment, MRI, or CT scanner
exists, or in the oxygen rich environment.
The air tube or the AC adapter cable may cause accidental strangulation in
infants.
Contained small parts that may cause a choking hazard if swallowed by infants.
(AC Adapter (optional) Usage)
Do not use the AC adapter if the device or the power co rd is damaged. Turn of f
the power and unplug the power cord immediately .
Plug the AC adapter into the appropriate voltage outlet. Do not use in a
multi-outlet plug.
Never plug in or unplug the power cord from the electric outlet with we t hands.
Caution: Indicates a potentially h azardous situation which , if not avoided,
may result in minor or moderate injury to the user or patient or
damage to the equip ment or other property .
(General Usage)
Always consult your physician. Self-diagnosis of measurement results and
self-treatment are dangerous.
People with severe blood flow problems, or blood disorde rs, should consult a
physician before using the device, as the arm cuff inflation can cause bruising.
Remove the arm cuff if it does not start deflating during the measurement.
Do not use this device on infants or persons who canno t express their intentions.
Do not use the device for any purpose other than measuring blood pressure.
Use only the approved arm cuff for this device. Use of other arm cuffs may result
in incorrect measurement results.
Do not use a mobile phone or oth er devices that emit electromagnetic fields,
near the device. This may result in incor rect operation of the device.
Do not disassemble the monitor or a rm cuff. This may cause an inaccurate
reading.
Do not use in a location with moisture, or a location where water may splash on
the device. This may damage the device.
Do not use the device in a moving vehicle (car , airplane).
Do not take measurements more than necessary . It may cause bruising due to
blood flow interference.
Consult your physician before using the device if you had a mastectomy .
Read "If your systolic pressure is more than 210 mmH g" of this instruction
manual, if your systolic pressure is known to be more than 210 mmHg. Inflating
to a higher pressure than necessar y may result in bruising where the arm cuff is
applied.
(AC Adapter (optional) U sage)
Fully insert the power plug into the outlet.
When disconnecting the power plug from the outlet, do not pull the po wer cord.
Be sure to pull from the power plug safely .
When handling the power cord, take care not to do the following:
Wipe the dust off from the power plug.
Unplug monitor when not in use.
Disconnect the power plug before cle aning.
Use only an OMRON AC adapter designed for this device. Use of unsupported
adapters may damage and/or may be hazardous to the device.
(Battery Usage)
Do not insert the batteries with their polarities incorrectly aligned.
Use only 4 “AA” alkaline or manganese batteries with this d evice. Do not use
other types of batteries. Do not use new and used batteries to gether .
Remove the batteries if the device will not be used for thre e months or more.
General Precautions
• Do not forcibly crease the arm cuff or the air tube excessively .
• Do not press the air tube while taking a measurement.
• T o unplug the air plug, pull on the air plug at the connectio n with the monitor , not
the tube itself.
• Do not drop the monitor or subject device to strong shocks or vibrations.
• Do not inflate the arm cuff when it is not wrap ped around your arm.
• Do not use the device outside the specified environment. It may cause an
inaccurate reading.
• Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental pollution.
1. Know Y our Device
Content s:
Monitor , arm cuff, battery set, instruction manual, quick start guide
Monitor:
Arm cuff:
Display:
1.1 Display symbols
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular
rhythm two or more times during the
measurement, the irregular heartbeat
symbol ( ) will appear on the display
with the measurement values.
An irregular heartbeat rhythm is defined
as a rhythm that is 25% less or 2 5%
more than the average rhythm d etected
while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol ( ) displays with your measurement results,
we recommend you consult your physician. Follow the dir ections of your
physician.
Movement Error Symbol ( )
The movement error symbol is displayed if you mo ve your body during the
measurement. Please remove the arm cuff, and wait 2 - 3 minutes.
T ake another measurement, remain still du ring measurement.
A verage V alue Symbol ( )
The average value symbol is displayed when you press and hold the memory
button for more than 3 seconds. The most r ecent average value appears on
the display screen.
Blood Pressure Level Indicator
2013 ESH/ESC Guidelines for the ma nagement of arterial hypertensio n
Definitions of hypertensio n by office and home blood pressure levels
These are from statistical values for blood pressure.
1.2 Before T aking a Measurement
T o help ensure an accurate read ing, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating
for 30 minutes before taking a measurement. Rest for at least 15 minutes
before taking the measurement.
2. S tress raises blood pressure. Avoid taking measurements during stressful
times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor . Rest your arm on a table so
that the arm cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your
physician. A single measurement does not provide an accurate indication of
your true blood pressure. Y ou need to take and record several re adings
over a period of time. Try to measure your blood pressure at the same time
each day for consistency .
2. Prep aration
2.1 Battery Inst allation
1. Remove th e battery c over .
2. Insert 4 “ AA” batteries as
indicated in the battery
comp artment.
3. Replace the ba ttery cover .
Notes :
• When the low battery symbol ( ) appears on the display , turn the monitor
off, then replace all batteries at the same time. Long life alkaline batteries
are recommended.
• The measurement values continue to be stored in memory even after the
batteries are replaced.
• The supplied batteries may have a shorter life.
Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawf ul disposal may cause environmental
pollution.
2.2 Setting the Date and T ime
Set the monitor to the correct date and time befo re taking a measurement for
the first time.
1. Press the button.
2. Push or to change the year .
Push button to confirm the year and then the month flashes. R epeat the
same steps to change the month, day , hour , and minute.
3. Press the ST ART/ST OP button to turn the monitor off.
Notes :
• If the batteries have been replaced, the date and time setting will need to be
reset.
• If the date and time are not set, “-:--” appears during or after measurement.
3. Using the Device
3.1 Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm.
Do not place the arm cuff over thick clothes.
1. Insert the air plug into th e air jack
securel y .
2. Wrap the arm cuff firmly in
place around your lef t upper
arm.
The bottom edge of the arm cuff
should be 1/2 inch (1 to 2 cm) above
the elbow . Air tube is on the inside of
your arm and aligned w ith your middle
finger .
3. Secure cl osed with th e
fabric fast ener .
Notes :
• When you take a measurement on the right
arm, the air tube will be at the side of your
elbow . Be careful not to rest your arm on the
air tube.
• The blood pressure can differ between the right arm and the left arm, and
the measured blood pressure values can be different. OMRON recommends
to always use the same arm for measurement. If the values between both
arms differ substantially , please check with your physician which a rm to use
for your measurements.
3.2 How to Sit Correctly
T o take a measurement, you need to be
relaxed and comfortably seated, un der
comfortable room temperature. A void
bathing, drinking alcohol or caffeine,
smoking, exercising or eating 30 minutes
before taking a measurement.
• Sit on a chair with your feet flat on the floor .
• Sit upright with your back straight.
• Sit with your back and arm being supported.
• The arm cuff should be placed on your ar m at
the same level as your heart.
3.3 T aking a Measurement
Notes:
• T o stop a measurement, press the ST ART/STOP button once to deflate the
arm cuff.
• Remain still while taking a measurement.
The monitor is designed to take measurements and store the measurement
values in the memory for 2 people using USER ID 1 and USER ID 2.
1. Select your User ID (1 or 2).
2. Press the ST ART/STOP button.
The arm cuff will start to inflate automatically .
3. Remove the arm cuff.
4.
Press the ST ART/STOP button to turn the monitor off.
The monitor automatically stores the measurement result in its memory .
It will automatically turn off after 2 minutes.
Note: Wait 2-3 minutes before taking another measurement. W aiting between
measurements allows the arteries to return to the condition prior to
taking a measurement.
Using the Guest Mode
The monitor stores measurement values for 2 users in the memory .
The guest mode can be used to take a single measurement for another user .
No measurement values are stored in the memory when the guest mode is
selected.
1. Press and hold the ST ART/STOP
button for more than 3 seconds.
The USER ID symbol and the Date/Time
display will disappear .
2. Release the ST ART/ST OP button when the Date/T ime disp lay
turns of f.
The arm cuff will start to inflate automatically .
DO NOT adjust medication based on measurement results from this blood
pressure monitor . T ake medication as prescribed by your physician. Only a
physician is qualified to diagnose and treat High Blood Pressure.
This device is not intended to be a diagno stic device.
Always consult your physician. Self-diagnosis of measurement r esults and
self-treatment are dangerous.
Inflating to a higher pressure than necessary may result in bruising where the
arm cuff is applied.
3.4 Using the Memory Functio n
The monitor automatically stores the results up to 50 set s for each user (1 and
2). It can also calculate an average value based on the last 3 measurement
values taken within 10 minutes.
Notes:
• If there are only 2 measurement values in the memory for that per iod, the
average will be based on these 2 values.
• If there is 1 measurement value in the memory for that period, this is
displayed as the average.
• If the memory is full, the monitor will delete the oldest value.
• When viewing the measurement value taken without setting the date and
time, “-:--” is displayed instead of the date and time.
T o V iew the Measurement V alues S tored in Memory
1. Select your User ID (1 or 2).
2. Press the button.
The Memory number appears for a second
before the pulse rate is displayed.
The newest set is numbered “1”.
3. Press the or button to view the values stored in mem ory .
:
T o view the older values
: T o view the more recent values
T o V iew the Average V alue
1. Select your User ID (1 or 2).
2. Press and hold the butt on for
more than 3 seco nds.
Notes:
• If the previous measurement was taken without setting the date and time,
the average value is not calculated.
• If there are no measurements results stored in the memory ,
the screen to the right is displayed.
T o Delete All t he V alues S tored in Memory
The values stored in the memory are deleted by USER ID.
1. Select your User ID (1 or 2).
2. Press the button, while the memory symbol appears.
3. While holding the button
down, press the
ST ART/STOP button for
more than 3 seco nds.
Note: Y ou cannot partially delete the values stored in the memory .
All values for the user you select will be deleted.
Do not damage. Do not break it.
Do not tamper with it. Do not forcibly bend or pull.
Do not twist. Do not bundle during use.
Do not pinch. Do not place under heavy objects.
2298802-0B
5 series
Blood Pressur e Monitor
Model BP742N
Instruction Manual
A. Display
B. Up/Down buttons
C. USER ID selection switch
D. Date/T ime setting button
E. ST ART/STOP button
F . Memory button
G . Battery compartment
H. Air jack
I. AC adapter jack
(for optional AC adapter)
M. USER ID symbol
N. Systolic blood pressure
O. Diastolic blood pressure
P . Low battery symbol
Q. Heartbeat symbol
(Flashes during measurement.)
R. Memory symbol
S. Average value symbol
T . Date/Time display
U. Movement error symbol
V . Irregular heartbeat symbol
W . Blood pressure level indicator
X. Deflation symbol
Y . Pulse display / Memory number
Office Home
Systolic Blood Pressure ≥ 140 mmHg ≥ 135 mmHg
Diastolic Blood Pressure ≥ 90 mmHg ≥ 85 mmHg
J. Arm cuff
(Arm circumference 9” - 17” (22 - 4 2 cm))
K. Air plug
L. Air tube
Irregular Heartbeat
Normal Heartbeat
Pulse
Blood pressure
Blood pressure
Short
Long
Pulse
Minu te
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Y ear
Month
Day
Hour
: Forward
: Back
ST ART INFLA TE DEFLA TE COMPLETE
If your systolic pressure is more t han 210 mmHg
After the arm cuff st arts to inflate, press and hold the ST ART/ST OP
button until the monitor inflates 30 to 40 mmHg higher than your
expected systolic pressure.
Notes:
• The monitor will not inflate above 299 mm Hg.
• Do not apply more pressure than necessary .
Alternating date/time
display