•Always Limit Your Dive to the Level of Your Training
and Experience
•Always Make Your Deepest Dive First
•Always Make The Deepest Part of Every Dive First
•Check Your Computer Often During the Dive
•Do A Safety Stop on Every Dive
•Allow Adequate Surface Interval Between Each Dive
•Allow Adequate Surface Interval Between Each Day of
Diving (12 Hours or Until Your Computer Clears)
Read And Understand This Owner's Guide
Thoroughly Before Using the Pro Plus.
Responsible
Datamax Pro Plus
iii
WARNINGS and SAFETY RECOMMENDATIONS
• The Pro Plus is intended for use by recreational divers who have successfully completed a
nationally recognized course in scuba diving, and diving with enriched nitrogen-oxygen
(nitrox) mixtures.
• It is intended only for no decompression diving, NOT intentional decompression diving.
• It must not be used by untrained persons who may not have knowledge of the potential risks
and hazards of scuba diving, and diving with enriched nitrogen-oxygen (nitrox) mixtures.
• You must obtain scuba certification, and certfication in diving with enriched nitrogen-oxy-
gen (nitrox) mixtures before using the Pro Plus if you have not already done so.
• It is NOT for use by military and commercial divers.
• It should NOT be utilized for any competitive, or repetitive square wave or decompression
diving, as it is intended solely for recreational use and no decompression multilevel diving.
• As with all underwater life support equipment, improper use or misuse of this product can
cause serious injury or death.
• Never participate in sharing or swapping of a dive computer.
• Conduct your dives in such a manner so as to insure that you continuously check the
computer's proper function.
• Read and understand this owner’s guide completely before diving with the Pro Plus.
• If you do not fully understand how to use this dive computer, or if you have any questions,
you should seek instruction in its use from your Authorized Oceanic Dealer before you uti-
lize this product.
®
iv
LIMITED TWO-YEAR WARRANTY
For details, refer to the Product Warranty Registration Card provided.
COPYRIGHT NOTICE
This owner’s guide is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine readable form without prior consent in writing from Oceanic / 2002 Design. The Surface Time/Mode, Plan Mode, No Decom-
pression Time, Decompression Stop Time, Dive Log, Low Battery, Elapsed Dive Time, Maximum Depth, Ascent Rate, and Caution Zone icons are protected by
copyright, and are trademarks of Oceanic.
Datamax Pro Plus Owner's Guide, Doc. No. 12-2141 (5/99)
Oceanic, the Oceanic logo, Datamax Pro Plus, the Pro Plus logo, Oceanglo, Smart Glo, Graphic Diver Interface, Tissue Loading Bar Graph, Pre Dive Planning
Sequence, Variable Ascent Rate Indicator, Set Point, Control Console, Turn Gas Alarm, and OceanLog are all registered and unregistered trademarks of Oce-
anic. All rights are reserved.
PATENT NOTICE
U.S. Patents have been issued, or applied for, to protect the following design features:
Graphic Diver Interface, Pre Dive Planning Sequence, Dive Time Remaining, Depth Alarm Set Point, Smart Glo, Main Menu Structure, Turn Gas Alarm Set
Point, End Gas Alarm Set Point, Depth Alarm Set Point, Breathing Gas Time Remaining Bar Graph, Data Sensing and Processing Device (U.S. Patent no.
4,882,678), Breathing Gas Time Remaining (U.S. Patent no. 4,586,136), and Variable Ascent Rate Indicator Bar Graph (U.S. Patent no. 5,156,055).
DECOMPRESSION MODEL
The programs within the Pro Plus simulate the absorption of nitrogen into the body by using a mathematical model. This model is merely a way to apply a
limited set of data to a large range of experiences. The Pro Plus dive computer model is based upon the latest research and experiments in decompression
theory. Still, using the Pro Plus, just as using the U.S. Navy (or other) No Decompression Tables, is no guarantee of avoiding decompression
sickness, i.e. “the bends.” Every diver’s physiology is different, and can even vary from day to day. No machine can predict how your body will react to a
particular dive profile.
R1
Datamax Pro Plus
v
FEATURES and DISPLAYS....................................................................................... 1
• To Set: Alternate On/Off................................................................................................................... 21
• To Set: Audible Alarm On/Off ........................................................................................................... 22
• To Set: Depth Alarm Set Point......................................................................................................... 22
• To Set: Turn Pressure Alarm Set Point............................................................................................ 23
• To Set: End Pressure Alarm Set Point ............................................................................................. 24
• To Set: Date/Hour Format/Time ....................................................................................................... 24
• To Set: Sampling Rate.....................................................................................................................26
• To Set: Units of Measure................................................................................................................. 27
• To Set: FO2 50% Default On/Off......................................................................................................27
EA Mode................................................................................................................................................. 28
Summary of Access to Set Modes .......................................................................................................... 30
PRE DIVE and DIVE MODES.................................................................................. 31
After the First 2 Hours ............................................................................................................................. 50
Downloading Data to PC......................................................................................................................... 50
Summary of Access to Post Dive Modes ................................................................................................ 52
HANDLING THE EXTREMES .................................................................................. 53
Avoiding and Managing Decompression................................................................................................. 54
• Tissue Loading Bar Graph............................................................................................................... 54
• Partial Pressure of Oxygen.............................................................................................................. 63
• High PO2 Dive Mode ....................................................................................................................... 63
• High Oxygen Accumulation.............................................................................................................. 64
Unexpected Loss of Displayed Information............................................................................................ 65
CARE and MAINTENANCE..................................................................................... 69
Care and Cleaning .................................................................................................................................. 70
Annual Inspections and Service .............................................................................................................. 70
• To Obtain Service............................................................................................................................ 71
Service Record....................................................................................................................................... 90
1
Datamax Pro Plus
FEATURES
and
DISPLAYS
refer to page 16 for - WARNINGS and SAFETY RECOMMENDATIONS
2
®
INTRODUCTION
Welcome to Oceanic and thank you for choosing the Pro Plus !
The Pro Plus has a wide array of features described in detail throughout the
pages that follow. Due to the importance that they be understood thoroughly
prior to using the Pro Plus, information will be expanded upon and some re-
freshed as you proceed. Relax and read through the complete guide.
It is extremely important that you read this owner's guide in se-
quence and understand it completely before attempting to use the
Pro Plus.
Remember that technology is no substitute for common sense, and a dive com-
puter only provides the person using it with data, not the knowledge to use it.
INTERACTIVE CONTROL CONSOLE
The Interactive Control Console, consisting of the Advance (Left) button and
Select (Right) button (Fig. 1), allows you to select various display options and
access specific information when you choose to see it. The buttons can be
pressed repeatedly, or held in to scroll.
Fig. 1 - Interactive
Control Console
SelectAdvance
OCEANIC
20051030405060
Smart
Glo
NO DECO
C Z
Pro PLUS
DECO
C ZO
2
™
®
PSI
MAX
FT
BAR
M
FT
M
2
O
MAX
47
Datamax Pro Plus
NO DECO
C Z
DECO
C ZO
2
NO DECO
C Z
DECO
C ZO
2
NO DECO
C Z
DECO
C ZO
2
The Pre Dive Planning Sequence will only scroll to the maximum depth al-
lowed by the nitrogen or oxygen limit, whichever is in control. The respective
bar graph will be displayed to indicate which is in control.
To access Time to Fly and Desaturate Countdowns:
• press the Advance (Left) button 4 times (while in Surface Mode)
• press the Select (Right) button to view the sequence
• The unit reverts to Surface Mode after 2 minutes, unless the Advance
(Left) button is pressed to access the Log Mode.
The Time To Fly counter begins counting down 10 minutes after the last dive
has ended (after the 10 minute Transition Period) displaying the word 'FLY'
with a countdown (Fig. 51a) that starts at 23:50 (hr:min) and counts down to
0:00 (hr:min).
The Time to Desaturate counter (Fig. 51b), provides calculated time for tissue
desaturation at sea level. The countdown starts at 9:59 (hours:minutes) maxi-
mum and counts down to 0:00. If the time is calculated to be greater than
9:59, the display will indicate 9:- - (Fig. 52a) until it decreases to 9:59.
If a violation occurred during the dive, Time to Desaturate will not be dis-
played and a single dash ( - ) will appear (Fig. 53a) instead of the letters FLY.
Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.
Product:
Spelregels forum
Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:
lees eerst de handleiding door;
controleer of uw vraag al eerder door iemand anders is gesteld;
probeer uw vraag zo duidelijk mogelijk te stellen;
heeft u een probleem en al geprobeerd om dit op te lossen, vermeld dit erbij aub;
heeft u een oplossing gekregen van een bezoeker dan horen wij dat graag in dit forum;
wilt u een reactie geven op een vraag of antwoord, gebruik dan niet dit formulier maar klik op de knop 'reageer op deze vraag';
uw vraag wordt direct op de website gezet; vermijd daarom persoonlijke gegevens in te vullen;
Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.
Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.
Abonneren
Abonneer u voor het ontvangen van emails voor uw Oceanic DataMax Pro Plus bij:
nieuwe vragen en antwoorden
nieuwe handleidingen
U ontvangt een email met instructies om u voor één of beide opties in te schrijven.
Ontvang uw handleiding per email
Vul uw emailadres in en ontvang de handleiding van Oceanic DataMax Pro Plus in de taal/talen: Engels als bijlage per email.
De handleiding is 1,09 mb groot.
U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.
Stel vragen via chat aan uw handleiding
Stel uw vraag over deze PDF
Andere handleiding(en) van Oceanic DataMax Pro Plus
Uw handleiding is per email verstuurd. Controleer uw email
Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.
Er is een email naar u verstuurd om uw inschrijving definitief te maken.
Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken
U heeft geen emailadres opgegeven
Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.
Uw vraag is op deze pagina toegevoegd
Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.