554364
110
Verklein
Vergroot
Pagina terug
1/114
Pagina verder
®
WARNING:
Read and understand the
contents of this guide
prior to using the
DataTrans. You should
seek the advice of your
retailer in its use and
limitations prior to diving
with this product. Should
you not understand the
contents of this guide, or
have any questions, you
should seek additional
training in the use of this
product from your
retailer. This product is
for recreational multilevel
diving use only and is
designed for use by
competently trained
individual divers only.
DATATRANS
®
owner's guide
iii
WARNINGS:
• The DataTrans is intended for use only by recreational divers who have successfully completed a
nationally recognized course in scuba diving.
• It must not be used by untrained persons who may not have knowledge of the potential risks and
hazards of scuba diving.
• You must obtain scuba certification before using the DataTrans if you have not already done so.
• It is NOT for use by commercial divers.
• It should NOT be utilized for any competitive, or repetitive square wave or decompression diving, as it
is intended solely for recreational use and no decompression multilevel diving.
• As with all underwater life support equipment, improper use or misuse of this product can cause
serious injury or death.
• Never participate in sharing or swapping of a dive computer.
• Conduct your dives in such a manner so as to insure that you continuously check the computer's
proper function.
• Read and understand this owner’s guide completely before diving with the DataTrans.
• If you do not fully understand how to use this dive computer, or if you have any questions, you should
seek instruction in its use from your authorized Oceanic dealer before you utilize this product.
Pay special attention to items marked with this Warning symbol.
iv
LIMITED TWO-YEAR WARRANTY
Oceanic guarantees, to the original purchaser only, that the DataTrans will be free of defects in materials and/or craftsmanship under
normal recreational multilevel scuba use for two years from date of purchase, provided proper care and annual service are performed as
described within this owner’s guide. Should your DataTrans prove to be defective for any reason (other than those listed in the limitations
section below) it will be repaired or replaced (at Oceanic’s discretion) free of charge excluding shipping and handling charges. This
warranty will be considered void if the DataTrans was purchased from anyone other than an Authorized Oceanic Dealer,
and/or if the registration card is not filled out completely at the time of purchase and mailed to Oceanic within 30 days of purchase, and/or if
the annual inspection is not done according to this owner’s guide. This warranty is non-transferrable and applies to the original purchaser
only. All correspondence concerning this warranty must be accompanied by a copy of the original sales receipt and a copy of the owner’s
portion of the warranty registration card including the annual inspection record.
Once each year you must return the DataTrans to an Authorized Oceanic Dealer within 30 days of the original purchase date anniversary
to keep the two year limited warranty in force. Annual inspection includes verification of depth accuracy and proper general function.
Labor charges for the annual inspection are not covered by the warranty. You must provide a copy of the original sales receipt and a copy of
the owner’s portion of the warranty registration card including the annual service record to obtain warranty service. If you try to obtain
warranty service for your DataTrans but have not sent in the registration within 30 days of purchase date, you will be charged a twenty-five
dollar late registration processing fee to reinstate the warranty. This charge can be avoided by mailing the registration card immediately
after purchase.
Statement of Limitations - General:
Warranty does not cover damage from accident, abuse, battery leakage, tampering, lack of proper care and maintenance
and/or proper annual servicing, or improper use of the DataTrans. Modifications or repair by anyone other than an Oceanic Sales
& Service Center authorized to service the DataTrans will void the warranty. Oceanic will not be responsible for recovery or replacement of
the product in the event of loss or theft. Oceanic, its distributors, and retailers make no warranties, either expressed or implied, with
respect to this product or its owner’s guide except those stated in the preceding paragraphs. In consideration of the sale of the
DataTrans to you, you agree and understand that in no event will Oceanic, its distributors or retailers, be held liable for
any personal injuries resulting from its operation, or for any other damages whether direct, indirect, incidental, or
consequential even if Oceanic is advised of such damages.
Some states do not allow the exclusion or limitation of implied warranties or liabilities for incidental or consequential damages, so the above
limitation may not apply to you.
Warranty does not extend to plastic gauge face, rubber strap, o-rings, batteries, transmitter fitting corrosion, chrome loss, or damage due to
accident, abuse, modification, or tampering.
v
FCC ID: MH8A
FCC Compliance:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause
harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Interference Statement:
This equipment has been tested and found to comply with the limits for an Intentional Radiator, a Class B Digital Device, pursuant to Part
15 of FCC Rules, Title 47 of the Code of Federal Regulations. These limits are designed to provide reasonable protection against harmful
interference in a commercial or residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause interference to radio communications.
There is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference
by one or more of the following measures:
a. Reorient or relocate the receiving antenna.
b. Increase the separation between the equipment and the affected receiver.
c. Connect the equipment and the affected receiver to power outlets on separate circuits.
d. Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by Oceanic could void the user's authority to operate the equipment.
DECOMPRESSION MODEL
The programs within the DataTrans simulate the absorption of nitrogen into the body by using a mathematical model. This model is
merely a way to apply a limited set of data to a large range of experiences. The DataTrans dive computer model is based upon the latest
research and experiments in decompression theory. Still, using the DataTrans, just as using the U.S. Navy (or other) No Decompression
Tables, is no guarantee of avoiding decompression sickness, i.e. “the bends.” Every diver’s physiology is different, it even varies from day to
day. No machine can predict how your body will react to a particular dive profile.
vi
* The blank Oceanic DiveLog in the reference section may be duplicated for personal use only, not for resale.
COPYRIGHT NOTICE
This owner’s guide is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine readable form without prior consent in writing from Oceanic.* The Surface Time/Mode, Plan
Mode, Air Time, No Decompression Time, Decompression Stop Time, Dive Log, Transmitter Low Battery, Receiver Low Battery, Link,
Temperature, Bottom Time, Maximum Depth, Ascent Rate, Air Consumption, and Caution Zone icons are protected by copyright, and are
trademarks of Oceanic.
DataTrans Owner's Guide, Product Number 12-1872
© OCEANIC 1995
2002 Davis St.
San Leandro, Ca. USA 94577
510/ 562-0500
TRADEMARK NOTICE
Oceanic, the Oceanic logo, Diving Essentials Redefined, DataTrans, DX3 Integrated, Graphic Diver Interface, Tissue Loading Bar Graph,
Pre Dive Planning Sequence, Variable Ascent Rate Indicator, Air Time Remaining, Message Box, Set Point, Control Console, OceanLink,
and Oceanglo are all registered and unregistered trademarks of Oceanic. All rights are reserved.
PATENT NOTICE
U.S. Patents have been issued, or applied for, to protect the following design features:
Air Time Remaining (U.S. Patent no. 4,586,136), Dive Time Remaining, Graphic Diver Interface, Pre Dive Planning Sequence, Data
Sensing and Processing Device (U.S. Patent no. 4,882,678), Tissue Loading Bar Graph (U.S. Patent no. 4,882,687), Variable Ascent Rate
Indicator Bar Graph (U.S. Patent no. 5,156,055), Air Time Remaining Bar Graph, Variable Air Consumption Bar Graph, DataTrans
Message Box, DataTrans Mode Menu Structure, Air Alarm Set Point, and Depth Alarm Set Point.
vii
CONTENTS
I. FEATURES OVERVIEW ..................................................................................................1
II. GETTING STARTED........................................................................................................9
III. DIVING WITH THE DATATRANS ...............................................................................29
IV. HANDLING THE EXTREMES ......................................................................................55
V. CARE AND MAINTENANCE ........................................................................................71
VI. REFERENCE ..................................................................................................................81
LANGUAGE CROSS REFERENCE..............................................................................93
INDEX ............................................................................................................................101
viii
®
COMPUTER
®
RESPONSIBLE COMPUTER DIVING
DIVING
Always Plan Each Dive
Always Limit Your Dive to the Level of Your Training
and Experience
Always Make Your Deepest Dive First
Always Make The Deepest Part of Every Dive First
Check Your Computer Often During the Dive
Do A Safety Stop on Every Dive
Ensure Adequate Surface Interval Between Each Dive
Ensure Adequate Surface Interval Between Each Day of
Diving (12 Hours or Until Your Computer Clears)
Read And Understand This Instruction Manual
Thoroughly Before Using the DataTrans.
Responsible
1
FEATURES
OVERVIEW
2
INTRODUCTION
Welcome to Oceanic and thank you for choosing DataTrans! We feel that
your new DataTrans will surpass your highest expectations as you become familiar
with its broad assortment of features and unique, interactive capabilities that give
it the distinction of being a personal diving computer.
The complete DataTrans is a two component, air integrated system that consists
of a computer 'display module' and a Radio Frequency (R/F) 'transmitter' that will
be installed into a high pressure port of your first stage, or is built into an Oceanic
DX-2
Integrated first stage. This transmitter continuously “sends” air supply data
to the display module via a low frequency signal. In addition to no-decompression/
decompression status, air consumption is then calculated and displayed in graphic
and alpha/ numerical formats on the computer’s screen - all without the use of wires
or hoses!
The computer module can also be used without the transmitter as a “stand-
alone,” non air-integrated computer, and will retain full use of all functions except
those that are air related. It can therefore be purchased separately, and a
transmitter can be added at any time in the future to make full use of the DataTrans'
available features.
If navigating through the various modes of the DataTrans’ menu system seems
complicated at first, relax. As you read through this Instruction Guide, you will see
that the mode settings are actually easier to understand and perform than those of
®
PSI
FT
3
most digital wrist watches. Refer to the icon legend and menu structure chart on
the following pages, and keep the waterproof Review Card handy during your dive
trips. Although it will require an initial investment of time to become acquainted
with the various icons and bar graphs of the Graphic Diver Interface, you’ll soon
agree that the DataTrans is amazingly easy to use, and intuitively simple to
understand - at a glance! After all, why spend any more time than necessary
studying a computer screen, when there are far more interesting things to look at
underwater?
The DataTrans has a wide array of features that are described in detail
throughout the following pages. It is extremely important that you read this
manual in sequence and understand it completely before attempting to
use the DataTrans. Check the DataTrans frequently during your dive.
You must also be a trained diver, certified by a recognized training agency.
Remember at all times: The rules you were taught in your basic, open water
certification course still apply to the diving you will do while using a dive computer
- some will become doubly important. Technology is no substitute for common
sense, and a dive computer can only be as smart as the person using it.
Be a RESPONSIBLE DIVER at all times.
R
E
S
P
O
N
S
I
B
L
E
D
I
V
E
R
4
®
®
Fig. 2 – Interactive Console -
Dive Mode Functions
BACKLIGHT ALTERNATE MODE ACCESS
ADVANCE SELECT
Fig. 1 – Interactive Console -
Surface Functions
OVERVIEW OF FEATURES
The DataTrans is very unique among diving computers presently available, due
to its powerful interactive features that allow you - the user - to select various display
options, and to access specific information you need, when you choose to see it. The
key to these features is the Interactive Control Console, which consists of the
ADVANCE button and SELECT button (Fig. 1). On the surface, prior to entering
the water, these controls allow you to preset the following display options:
• Units of Measure - Imperial or Metric
• Message Box™ Language - English, Italian, German, Spanish, or French
• Custom Depth & Air Warning Set Points™
• Date & Time
• Link - Display Module to a Transmitter
You may choose to set these options only one time and leave them at those
settings, or you may set them at different values any time while on the surface.
The controls can be pressed repeatedly , releasing upon hearing a beep, or held in
to scroll and continue as you set or access different display modes that you choose.
On the surface, you may select the Plan mode to plan your next dive, or choose the
Log mode with time and date stamp to access your 12 most recent dives. A History
mode displays the unit's complete history, including total number of dives, maxi-
mum depth, etc. After the DataTrans enters Dive mode underwater, the AD-
VANCE button may be used to backlight the display, and the SELECT button used
to access an Alternate Dive mode, which displays additional information includ-
ing maximum depth, bottom time and temperature (Fig 2).
5
Fig. 3 - Universal Graphic
Diver Interface
Universal Graphic Diver Interface
®
One of Oceanic’s primary design objectives for dive computers has always been
to display information in a format which is as easy to read and understand as
possible, without any clutter of unnecessary information that may cause confusion
for the diver. Until now, this has been accomplished by alternately showing
primary and secondary screens of information at preset intervals. This allows the
numerical figures for each display to be as large and as easy to read as possible, but
it comes with the small inconvenience of sometimes waiting until the screen
containing the desired information appears.
The DataTrans offers the best of all worlds, and transcends many language
barriers. With the use of universal icons and four different bar graphs that make
up the Universal Graphic Diver Interface (Fig. 3), information is visually repre-
sented and understood at a glance, minimizing the need for numerical displays.
Underwater, the Control Console allows you to access an alternate display of
information containing max depth, bottom time, and temperature, with the touch
of a button - whenever you choose.
In a critical situation, however, icons, bar graphs, and numeric displays may not
be enough to convey an urgent message. The Message Box
TM
is an alpha/numeric
display which flashes concise, simple messages, such as “TOO FAST,” or “AIR
ALARM,” while the audible alarm simultaneously sounds to alert you to check this
information. Most incredibly, these messages can be displayed in one of five
language preferences that you choose, using the interactive Control Console before
you enter the water.
6
PSI
M
FT
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
Kg/Cm
2
Color Coded Bar Graph Displays
The Graphic Diver Interface contains four separate bar graphs that are each color
coded green, yellow, and red, and can be interpreted the same as a traffic signal.
The Tissue Loading Bar Graph
®
(TLBG) represents (Fig. 4a) nitrogen loading,
showing your relative no-decompression or decompression status. As your depth
and bottom time increase, segments will fill the graph from left to right. As you
ascend to shallower depths, this bar graph will begin to recede, indicating that
additional no decompression time is allowed for multilevel diving. The TLBG also
assists you with managing decompression by indicating four “ceiling depths. This
is explained in detail in the “Handling the Extremes” section.
The Variable Ascent Rate Indicator
TM
(VARI) bar graph (Fig. 4b) shows you
how fast you are ascending, rather than just showing that you are ascending too
fast. You can think of it as an ascent rate speedometer.
The Air Time Remaining™ (ATR) bar graph (Fig. 4c) provides a graphic
representation of Air Time Remaining, which represents the time that a diver can
remain at his present depth and then, following a safe ascent, surface with a
predetermined air reserve (e.g., 300 psi). This calculation and display is based on
the diver's individual air consumption rate that is continually monitored by the
DataTrans, and it takes into account the air required for a safe ascent including any
required decompression stops.
The Air Consumption Indicator™ (ACI) bar graph (Fig. 4d) is a true biofeed-
back monitor that indicates your current breathing rate as compared to your
personally established breathing parameters. The comparison is based upon an
average rate established during the first 70 seconds of breaths.
Fig. 4 - Bar Graph Displays
d.
c.
a.
b.
7
While underwater, you must check each of these four bar graphs on a frequent
basis. Oceanic strongly recommends that every effort should be made to keep each
display “in the green” at all times to minimize any possibility of decompression
sickness or an out-of-air situation. More detailed information regarding these
displays is provided in the following sections.
In addition to it's unique interactive abilities, the DataTrans is fully loaded with
all of the features you would expect from the world's leading manufacturer of dive
computers - and much, much more:
Universal Graphic Diver Interface™ - Intuitively simple to read and understand
Air-Integrated
- Calculates personal air consumption in 3 displays
Alpha-Numeric Message Box
- Displays warning messages in preferred language
Audible Alarm - Alerts you to check Message Box
and Graphic Diver Interface
Variable Ascent Rate Indicator
- Measures ascent rate incrementally
Dive Log Recall - Recalls 12 most recent dive profiles with time & date stamp
Backlighted Display - Allows easy viewing at night or in low light situations
Automatic Altitude Compensation - Fully functional up to 14,000 ft. (4,267 m.)
Diver Replaceable Batteries
Ambient Temperature Indication
Before moving on to the next chapter, take the time to familiarize yourself with
the universal icons, Fig. 5 on page 8, which make up the Graphic Diver Interface.
8
1. Tissue Loading Bar Graph
(NO DECOM ZONE)
2. Tissue Loading Bar Graph
(CAUTION ZONE)
3a. Tissue Loading Bar Graph
(10ft/ 3m DECOM CEILING)
3b. Tissue Loading Bar Graph
(20ft/ 6m DECOM CEILING)
3c. Tissue Loading Bar Graph
(30ft/ 9m DECOM CEILING)
3d. Tissue Loading Bar Graph
(40ft/ 12m DECOM CEILING)
4. Icon - Decompression Zone
5. Icon - Ascent Rate
6. Icon - Low Battery
(See Detail B)
7. Icon - Maximum Depth
8. Icon - Elapsed Bottom Time
9. Icon - Temperature
10. Icon - Air Time Remaining
11. Icon - RF Transmission Link
12. Icon - Dive Time Mode
(See Detail A)
13. Icon - Low Air Consumption
14. Icon - Log Mode
15. Icon - High Air Consumption
Fig. 5 - Graphic Interface
Legend
FT
/
M
/
M
Kg/Cm
2
PSI
M
FT
9
GETTING
STARTED
10
MAKING THE DATATRANS PERSONAL
Before you dive with the DataTrans for the first time, you will need to become
acquainted with its interactive features, and select your personal display
settings using the Control Console and Mode Menu.
If you intend to use your DataTrans as a complete system that includes the
high pressure transmitter, the transmitter must first be installed into a high
pressure port of your first stage, facing to one side - unless you purchased the DX-
3
Integrated First Stage, which includes the transmitter as a built-in compo-
nent (Fig. 6). Oceanic strongly recommends that this installation be performed
by an Authorized Oceanic Dealer at the time of purchase. If this is not possible,
refer to the instructions for this procedure on page 80.
NOTE: The DataTrans transmitter is compatible with all Oce-
anic first stages, but cannot be guaranteed to fit certain models
produced by other manufacturers. Check with your Authorized
Oceanic Dealer for compatibility with your first stage.
If your DataTrans display module and transmitter were packaged and shipped
from the factory as a complete system, the two units have already been “pre-
linked.” If the two units have been purchased separately by you or your
Authorized Oceanic Dealer, it will be necessary to link the display module to the
transmitter's frequency code. This can be easily verified upon activation.
Fig. 6 - DX-3 Integrated
First Stage
11
A DataTrans that has been packaged and sold as a stand alone computer
display module has been preset at the factory as a non-linked unit, but can easily
be linked with a transmitter at any time in the future.
ACTIVATING THE DISPLAY
Before activating the DataTrans display module, it is very important to
connect the first stage containing the transmitter to a full cylinder and pressur-
ize by opening the valve. Air pressure of 50 psi (3.5 kg/cm
2
) or more is necessary
to activate the transmitter. Position the display module within 3 feet (1 m) of
and parallel to the transmitter, and hold it in this location throughout the
activation process.
To activate the display of the display module, press the Select button on the
right side of the Control Console and release. The DataTrans will immediately
enter Diagnostic Mode (Fig. 7), which will display all “8’s,” followed by “dashes,”
and then a countdown from 9 to 0. The Message Box will read SELF - TEST until
the diagnostic check is completed, at which time the DataTrans will emit a single
beep to indicate a successful diagnostic check. If the display module is correctly
set to the same frequency code as the transmitter, the Link icon will disappear
and cylinder pressure will be displayed numerically. Also, the Air Time
Remaining (ATR) bar graph (Fig. 8) will fill indicating 60 minutes.
Throughout this process, the DataTrans checks its display functions, coded
frequency link to the transmitter, and battery voltage to ensure that everything
is working correctly. If any display or message varies from the information
presented here, return the DataTrans to your Oceanic Dealer for inspection. It
Fig. 8 - Link Verification
(ATR Bar Graph)
Fig. 7 - Diagnostic Mode
®
BEEEEP!!!
M
®
PSI
FT
Kg/Cm
2
12
®
PSI
FT
Fig. 9 - Low Battery Warning
a.
will also check the ambient barometric pressure, and calibrate its present depth
as zero. At elevations of 3,000 ft. (915 m) or higher, it will recalibrate itself to
measure depth in feet (meters) of fresh water.
WARNING - Never activate the DataTrans underwater. This may
result in inaccurate depth and no-decompression time displays.
Activation is not possible deeper than 4 ft. (1 m) underwater.
If 2 hours elapse after activation without making a dive, the DataTrans will
self-deactivate to save battery power. Check your display module before entering
the water to ensure that it doesn’t need reactivation.
During diagnostic mode, the DataTrans measures the battery voltage level of
both the display module and the transmitter to determine whether there is
sufficient voltage to complete a full day of diving.
WARNING - If either or both of the Low Battery icons remain on
display following activation (Fig. 9a), Oceanic strongly recom-
mends that you DO NOT dive until you have obtained battery
replacement. See battery replacement procedure on page 77.
If there is not enough battery voltage in the display module to complete a day
of diving, the DataTrans will either deactivate itself or not activate at all. If there
is not sufficient voltage in the transmitter to complete a full day of diving, the link
13
Fig. 10 - Unsuccessful Link
®
FT
PSI
icon and tank pressure of "00" PSI will flash on display (Fig. 10), indicating that
the display module is not receiving a signal.
FLASHING LINK ICON
If the display module has been successfully linked to the transmitter upon
activation, the Link icon and tank pressure will begin flashing on display
whenever the display module is moved out of the range of the transmitter while
in Surface Mode. When the display module is returned to its correct proximity
to the transmitter, the flashing will stop, and the Link icon will disappear within
5 seconds. Also the Air Time Remaining bar graph will reappear.
If a link was not established during activation, the Link icon will remain
flashing on display immediately following Diagnostic Mode, and tank pressure
of "00" PSI will be displayed, flashing. This indicates one of the following
conditions:
a. The transmitter was not pressurized prior to activation of the display
module.
b. The display module was not positioned in close proximity to the transmit-
ter during activation or correctly positioned parallel to it.
c. The transmitter’s battery voltage has dropped below the level required to
transmit a signal.
d. The display module is not correctly linked to the same coded frequency as
the transmitter.
14
Fig. 11 - Surface Mode
In the latter case, it will be immediately necessary to follow the prescribed
linking procedure outlined on page 24 to set the display module to the coded
frequency that matches that of the transmitter, or set a specific link code that
will allow the display module to function as a stand alone unit.
SURFACE MODE
Surface Mode immediately follows Diagnostic Mode after initial activation
(Fig 11), or after the linking procedure has been performed. It also appears after
a dive when you ascend shallower than 3 ft. (1m). Surface Mode is identified by
the Surface Time icon (Fig. 11a). Information displayed in Surface Mode is Tank
Pressure, Depth, Surface Time with flashing colon, Temperature, Time of Day
with colon flashing, the Air Time Remaining and Tissue Loading Bar Graphs, if
any, and the Air Consumption Indicator. The Date may be viewed as a secondary
display by pressing the Select button.
Surface Mode is also the default mode that the DataTrans will automatically
return to whenever it has been left unattended while in the Mode Menu for a
period of more than 5 minutes. You may find yourself automatically returned
there when you have completed a particular setting. While navigating through
the Mode Menu system, you can think of Surface Mode as “home port”.
MODE MENU SYSTEM
In just a moment, you’ll begin navigating through the Mode Menu system to
set the various display options that will make the DataTrans your personal
computer. If you followed the Linking procedure, you have already developed a
®
PSI
FT
a.
15
feel for how the Control Console works. The Advance button is used to move
through the Mode Menu and change each setting, and the Select button is used
to select the mode or setting that is currently on-screen. A brief glossary and
hierarchy of the menu system is as follows:
Mode - Each mode provides a different display of information, or access to a
submenu or setting. Some modes, such as Dive Mode and Surface Mode, are
entered into automatically. Others, such as the Plan Mode and Alternate Dive
Mode, are entered into via the Control Console, at the user’s option.
Menu - The main menu allows interactive access from the Surface Mode to Plan,
Log, History, Set, and External Access Modes.
Setting - These are display options, such as time, date, language, link and units
of measure (imperial or metric) that are determined by you - the user. You can
even preprogram your dive by setting the depth and air pressure at which you
will be alerted when you are going too deep or running low on air.
Take the time to become familiar with the Menu System by studying the
flowchart diagrams shown on the following pages.
NOTE: If the DataTrans is left unattended for five minutes while
in the Mode Menu, it will automatically return to Surface Mode.
16
Start in
Surface
Mode
FT
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
PSI
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
20
30 40
50
60
10
5
10
FT
/3
M
20
FT
/6
M
30
FT
/
9
M
40
FT
/
12
M
0
FT
/0
M
0
Surface Mode
(Default)
Plan Mode
(Pre Dive Planning Sequence )
Dive Log
(Dive Log Recall)
History Mode
(Complete Unit History)
Set Mode
(Access Sub-Menus)
External Access Mode
(Optional External Interface Feature)
Mode Menu
17
Set Mode
(Access Submenus)
Alarm Setting
(Set Air & Depth)
Language Setting
(Set Language)
Unit Setting
(Set Units of Measure)
20
30 40
50
60
10
5
0
20
30 40
50
60
10
5
0
20
30 40
50
60
10
5
0
20
30 40
50
60
10
5
0
20
30 40
50
60
10
5
0
20
30 40
50
60
10
5
0
20
30 40
50
60
10
5
0
Time Setting
(Set Time of Day)
Date Setting
(Set Today's Date)
Link Setting
(Set Frequency Link)
Start
in Set
Mode
Settings
18
®
Fig. 12 - Time of Day Setting
ADVANCE SELECT
®
SETTING THE MODES
Now you can begin setting your personal display preferences, using the
interactive Control Console and the Setting Submenu. You will initially set Time
and Date, followed by Units of measure and Language.
SET TIME
Time of day is displayed during the Surface and Alternate Dive modes, and
each dive recorded in Log Mode is “stamped” with the time of day that the dive
started. Your DataTrans has been factory set for 12:00 AM. To change to the
current Time, follow this procedure, beginning in Surface Mode:
1. Press the Advance button to enter the MODE Menu. MODE:PLAN will
appear, with PLAN flashing, indicating that Plan Mode is the first available
option.
2. Press the Advance button 3 more times to advance to the Set Mode
(MODE:SET will appear, with SET flashing). If you accidentally pass the Set
Mode, you will need to press the Advance button repeatedly until MODE:SET
appears. Press the Select button to select the Set Mode.
3. SET:TIME will appear, with TIME flashing.
4. Press the Select button to select the Time setting. Time of day will appear,
with the first digit flashing (Fig. 12).
5. To set the time, press the Advance button to change each digit until it
matches that of the current time, and press the Select button to set each digit
and move on to the next. Finally, press the Advance button to display either
102
O
Oceanic DiveLog
Blank page for duplication 91
Instructions 90
Off-gassing 61
Operating temperature 68
Operational Modes 33, 87
Operational Performance 88
Out of range 57
P
Permanent Violation Modes 65
Pre Dive Planning Sequence 33
R
Regulator Attachment 80
Repetitive decompression 82
S
Set Alarms 21, 23
Set Date 19
Set Language 27
Set Mode 87
Set Time 18
Set Units 20
Setting Link 25
Setting Modes 17
Sharing computers vi, 69
Signal pattern 30, 31
Surface mode 14
T
Tables, U.S. Navy 84
Time Setting 18
Time to Fly 42
Tissue Compartment 82
Tissue half-times 87
Tissue Loading Bar
Graph 36, 46, 59, 67, 88
Tissue Tracking 82
TLBG 38, 46, 88
Training iv, vi
Transmitter 10, 25, 80
U
U.S. Navy Tables 84
Units Settings 20
V
VARI 39, 46, 88
Variable Ascent Rate Indica-
tor 39, 46, 88
Violation modes 38
About 60
Delayed 62
Immediate 64
Permanent 65
W
Warranty
Exclusions iv
Limitations iv
Maintaining 73
Registration iv
110

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Oceanic Data Trans bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Oceanic Data Trans in de taal/talen: Engels als bijlage per email.

De handleiding is 3,63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info