554363
46
Verklein
Vergroot
Pagina terug
1/90
Pagina verder
owner's guide
DATA PLUS 2
OCEANIC
®
®
ii
RESPONSIBLE COMPUTER DIVING
Always Plan Each Dive
Always Limit Your Dive to the Level of Your Training
and Experience
Always Make Your Deepest Dive First
Always Make The Deepest Part of Every Dive First
Check Your Computer Often During the Dive
Do A Safety Stop on Every Dive
Allow Adequate Surface Interval Between Each Dive
Allow Adequate Surface Interval Between Each Day of
Diving (12 Hours or Until Your Computer Clears)
Read And Understand This Owner's Guide
Thoroughly Before Using the Data Plus 2.
Responsible
Data Plus 2
iii
WARNINGS and SAFETY RECOMMENDATIONS
• The Data Plus 2 is intended for use by recreational divers who have successfully completed a
nationally recognized course in scuba diving, and diving with enriched nitrogen-oxygen
(nitrox) mixtures.
• It is intended only for no decompression diving, NOT intentional decompression diving.
• It must not be used by untrained persons who may not have knowledge of the potential risks
and hazards of scuba diving, and diving with enriched nitrogen-oxygen (nitrox) mixtures.
• You must obtain scuba certification, and certfication in diving with enriched nitrogen-oxy-
gen (nitrox) mixtures before using the Data Plus 2 if you have not already done so.
• It is NOT for use by military and commercial divers.
• It should NOT be utilized for any competitive, or repetitive square wave or decompression
diving, as it is intended solely for recreational use and no decompression multilevel diving.
• As with all underwater life support equipment, improper use or misuse of this product can
cause serious injury or death.
• Never participate in sharing or swapping of a dive computer.
• Conduct your dives in such a manner so as to insure that you continuously check the
computer's proper function.
• Read and understand this owner’s guide completely before diving with the Data Plus 2.
• If you do not fully understand how to use this dive computer, or if you have any questions,
you should seek instruction in its use from your Authorized Oceanic Dealer before you uti-
lize this product.
®
iv
LIMITED TWO-YEAR WARRANTY
For details, refer to the Product Warranty Registration Card provided.
COPYRIGHT NOTICE
This owner’s guide is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine readable form without prior consent in writing from Oceanic / 2002 Design. The Surface Time/Mode, Plan Mode, No Decom-
pression Time, Decompression Stop Time, Dive Log, Low Battery, Elapsed Dive Time, Maximum Depth, Ascent Rate, and Caution Zone icons are protected by
copyright, and are trademarks of Oceanic.
Data Plus 2 Owner's Guide, Doc. No. 12-2144 (5/99)
© 2002 Design 1999
2002 Davis Street
San Leandro, Ca. USA 94577
510/569-3100
TRADEMARK NOTICE
Oceanic, the Oceanic logo, Data Plus 2, the Data Plus 2 logo, Oceanglo, Smart Glo, Graphic Diver Interface, Tissue Loading Bar Graph, Pre Dive Planning
Sequence, Variable Ascent Rate Indicator, Set Point, Control Console, and OceanLog are all registered and unregistered trademarks of Oceanic. All rights are
reserved.
PATENT NOTICE
U.S. Patents have been issued, or applied for, to protect the following design features:
Graphic Diver Interface, Pre Dive Planning Sequence, Dive Time Remaining, Depth Alarm Set Point, Smart Glo, Mode Menu Structure, Data Sensing and
Processing Device (U.S. Patent no. 4,882,678), Tissue Loading Bar Graph (U.S. Patent no. 4,882,687), and Variable Ascent Rate Indicator Bar Graph (U.S.
Patent no. 5,156,055).
DECOMPRESSION MODEL
The programs within the Data Plus 2 simulate the absorption of nitrogen into the body by using a mathematical model. This model is merely a way to apply a
limited set of data to a large range of experiences. The Data Plus 2 dive computer model is based upon the latest research and experiments in decompression
theory. Still, using the Data Plus 2, just as using the U.S. Navy (or other) No Decompression Tables, is no guarantee of avoiding decompres-
sion sickness, i.e. “the bends.” Every diver’s physiology is different, and can even vary from day to day. No machine can predict how your body will react
to a particular dive profile.
Data Plus 2
v
FEATURES and DISPLAYS ....................................................................................... 1
Introduction ............................................................................................................................................. 2
Interactive Control Console ................................................................................................................... 2
Informational Displays ........................................................................................................................... 3
•• Universal Graphic Diver Interface..................................................................................................... 4
• Tissue Loading Bar Graph ............................................................................................................ 4
• Oxygen Accumlation Bar Graph ................................................................................................... 5
• Variable Ascent Rate Indicator ...................................................................................................... 6
•• Dive Time Remaining ....................................................................................................................... 7
• No Decompression Dive Time Remaining .................................................................................... 7
• Oxygen Accumulation Time Remaining ........................................................................................ 8
•• Alpha / Numeric Displays.................................................................................................................. 9
• Depth Displays.............................................................................................................................. 9
• Time Displays ............................................................................................................................... 9
Ambient Temperature .................................................................................................................. 10
Backlight Feature .................................................................................................................................. 10
Operating Temperature......................................................................................................................... 11
ACTIVATION and SETUP ........................................................................................ 13
Activation ............................................................................................................................................... 14
Surface Mode ........................................................................................................................................ 14
Main Mode Menu ................................................................................................................................... 15
Entering Settings .................................................................................................................................. 16
•• To Set: Alternate On/Off.................................................................................................................. 16
•• To Set: Date/Hour Format/Time ...................................................................................................... 17
•• To Set: Sampling Rate .................................................................................................................... 18
•• To Set: Units of Measure ................................................................................................................ 19
•• To Set: FO2 50% Default On/Off .................................................................................................... 19
CONTENTS
®
vi
CONTENTS (CONTINUED)
EA Mode ................................................................................................................................................. 20
Summary of Access to Set Modes ...................................................................................................... 22
PRE DIVE and DIVE MODES .................................................................................. 23
Operational Modes................................................................................................................................ 24
•• Temperature/Date/Time Mode ........................................................................................................ 24
•• FO2 Mode....................................................................................................................................... 24
• FO2 50% Default ........................................................................................................................ 25
• FO2 Set for an Air Dive ............................................................................................................... 25
• Setting FO2................................................................................................................................. 26
• FO2 Set for a Nitrox Dive............................................................................................................ 26
•• Pre Dive Planning Sequence.......................................................................................................... 27
• Prior to a Repetitive Dive ............................................................................................................ 28
•• No Decompression Dive Mode ....................................................................................................... 29
• Main Display ............................................................................................................................... 29
• Secondary Display ...................................................................................................................... 30
Alternate Display ......................................................................................................................... 30
Ascending to the Surface ..................................................................................................................... 32
Altitude Diving ....................................................................................................................................... 33
POST DIVE MODES................................................................................................. 35
First 2 Hours After a Dive ..................................................................................................................... 36
•• Transition Period............................................................................................................................. 36
• To view Temperature/Date/Time ................................................................................................. 36
• To view That Dive's Log .............................................................................................................. 37
Data Plus 2
vii
CONTENTS (CONTINUED)
After the Transition Period ................................................................................................................... 37
•• To view Temperature/Date/Time ..................................................................................................... 37
•• To access FO2 Mode ...................................................................................................................... 38
•• To access Pre Dive Planning Sequence......................................................................................... 38
•• To access Time to Fly and Desaturate Countdowns ...................................................................... 39
Log Mode ............................................................................................................................................... 40
After the First 2 Hours .......................................................................................................................... 42
Downloading Data to PC ...................................................................................................................... 42
Summary of Access to Post Dive Modes............................................................................................ 44
HANDLING THE EXTREMES .................................................................................. 45
Avoiding and Managing Decompression ............................................................................................ 46
•• Tissue Loading Bar Graph .............................................................................................................. 46
•• Decompression Dive Mode ............................................................................................................ 47
• Main Display ............................................................................................................................... 47
• Secondary Display ...................................................................................................................... 48
Alternate Display ......................................................................................................................... 48
•• Managing Decompression Stops.................................................................................................... 48
Violation Modes..................................................................................................................................... 49
•• Conditional Violation Mode ............................................................................................................. 49
•• Delayed Violation Mode.................................................................................................................. 50
•• Immediate Violation Mode .............................................................................................................. 51
•• Gauge Mode ................................................................................................................................... 52
•• Permanent Violation ....................................................................................................................... 52
Exceeding Maximum Operating Depth ...............................................................................................53
®
viii
CONTENTS (CONTINUED)
Oxygen Exposure ................................................................................................................................. 53
•• Partial Pressure of Oxygen............................................................................................................. 53
•• High PO2 Dive Mode ...................................................................................................................... 54
•• High Oxygen Accumulation ............................................................................................................ 54
Unexpected Loss of Displayed Information ....................................................................................... 55
CARE and MAINTENANCE ..................................................................................... 59
Care and Cleaning ................................................................................................................................ 60
•• After the Dive ................................................................................................................................. 60
Annual Inspections and Service .......................................................................................................... 60
•• To Obtain Service ........................................................................................................................... 61
Battery Life ............................................................................................................................................ 62
Low Battery Condition.......................................................................................................................... 63
Battery Replacement ............................................................................................................................ 63
•• Module Removal from Boot ............................................................................................................ 63
•• Battery Removal ............................................................................................................................. 64
•• Battery Installation .......................................................................................................................... 66
•• Inspection ....................................................................................................................................... 67
Returning the Module to Boot ............................................................................................................. 67
REFERENCE ............................................................................................................ 69
No Decompression Limits.................................................................................................................... 71
Decompression Model.......................................................................................................................... 71
Oxygen Exposure Limits ...................................................................................................................... 72
Multiple Tissue Tracking ...................................................................................................................... 72
Specifications........................................................................................................................................ 74
Glossary................................................................................................................................................. 77
Service Record ...................................................................................................................................... 80
1
Data Plus 2
FEATURES
and
DISPLAYS
refer to page 12 for - WARNINGS and SAFETY RECOMMENDATIONS
2
®
INTRODUCTION
Welcome to Oceanic and thank you for choosing the Data Plus 2 !
The Data Plus 2 has a wide array of features described in detail throughout the
pages that follow. Due to the importance that they be understood thoroughly
prior to using the Data Plus 2, information will be expanded upon and some
refreshed as you proceed. Relax and read through the complete guide.
It is extremely important that you read this owner's guide in se-
quence and understand it completely before attempting to use the
Data Plus 2.
Remember that technology is no substitute for common sense, and a dive com-
puter only provides the person using it with data, not the knowledge to use it.
INTERACTIVE CONTROL CONSOLE
The Interactive Control Console consisting of the Advance (Left) button and
Select (Right) button (Fig. 1) allows you to select various display options and
access specific information when you choose to see it. The buttons can be
pressed repeatedly, or held in to scroll.
Fig. 1 - Interactive
Control Console
SelectAdvance
O
2
M
FT
FT
MAX
M
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
OCEANIC
Smart
Glo
DataPlus2
®
MAX
3
Data Plus 2
INFORMATIONAL DISPLAYS
Operational modes and status information are visually represented numeri-
cally and/or graphically and can be understood at a glance with the aide of uni-
versal icons (Fig. 2) that identify and bring quick focus to the displays. Seg-
mented bar graphs will show how close you are to critical limits.
Each Data Plus 2 numeric and graphic display represents a unique
piece of information. It is imperative that you understand the for-
mats, ranges, and values of the information represented to avoid any
possible misunderstanding that could result in error.
NOTE: Throughout this owner's guide reference is made to the
term ''breathing gas'. The rational being that the Data Plus 2
can be used for 'air' dives or 'nitrox' dives. For clarity these
terms are defined as -
Breathing Gas - the gaseous mixture breathed during a dive.
Air - a breathing gas that contains approximately 21% oxygen
and 79% nitrogen (nature's common nitrogen-oxygen mixture).
Nitrox - a nitrogen-oxygen breathing gas that contains a higher
fraction of oxygen (22 to 50%) than air.
Fig. 2 - Universal Icons
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a. Operating Mode
b. Elapsed Dive Time
c. Low Battery
d. Temperature
e. Deco Stop
f. Log
g. Maximum Depth
a
b
c
d
e
f
g
4
®
UNIVERSAL GRAPHIC DIVER INTERFACE
Three bar graphs referred to as the Universal Graphic Diver Interface
appear
around the perimeter of the screen (Fig. 3). These segmented bar graphs are
located next to green, yellow, and red color coded portions of the peripheral
decal that denote normal, caution, and danger zones, respectively.
When underwater, you can quickly focus on the bar graphs to make sure that
they are in the green. You can quickly verify that you're not getting too close
to the no decompression limit or the limit for exposure to oxygen (accumula-
tion), or ascending too fast.
Tissue Loading Bar Graph
The Tissue Loading Bar Graph
(TLBG) represents nitrogen loading (Fig. 4),
showing your relative no decompression or decompression status. As your
depth and elapsed dive time increase, segments will add to the graph begin-
ning in the lower left portion of the screen. As you ascend to shallower depths,
this bar graph will begin to recede, indicating that additional no decompres-
sion time is allowed for multilevel diving.
The Tissue Loading Bar Graph monitors 12 different nitrogen compartments
simultaneously and displays the one that is in control of your dive. It is di-
vided into a green No Decompression zone (NO DECO), a yellow Caution zone
(C.Z.), and a red Decompression zone (DECO). The bar graph gives a visual
Fig. 3 - Bar Graphs
Fig. 4 - Tissue Loading
Bar Graph
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
5
Data Plus 2
representation of just how close you are to the no decompression limit with a
yellow Caution (C.Z.) Zone.
This Caution Zone portion of the bar graph allows you to make a decision re-
garding safety stop duration or necessity. While you cannot provide a guaran-
tee against the occurrence of decompression sickness, you may choose your
own personal zone of caution based upon age, physique, excessive weight, etc.,
to reduce the statistical risk.
The Tissue Loading Bar Graph also assists you with managing decompression
(explained later) by filling a large red 'ceiling stop required' segment.
The Tissue Loading Bar Graph
has been garanted U.S. Patent No. 4,882,687.
Oxygen Accumulation (O2) Bar Graph
NOTE: Displays associated with oxygen and the O2 bar graph
will only appear if FO2 has been set at a value other than 'Air'.
The Oxygen Accumulation (O2) Bar Graph (Fig. 5) represents oxygen loading,
your relative oxygen tolerance dosage (OTU), showing the maximum of either
per dive accumulated oxygen, or 24 hour period accumulated oxygen. As your
exposure (accumulation of oxygen) increases during the dive, segments will
add to the bar graph starting in the lower right portion of the screen. As oxy-
Fig. 5 - Oxygen Accumulation
(O2) Bar Graph
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
6
®
gen loading decreases, the bar graph will begin to recede, indicating that addi-
tional exposure (accumulation) is allowed for that dive, and 24 hour period.
The O2 bar graph also assists you with managing high partial pressure of oxy-
gen (PO2) by flashing the large red Danger zone segment as a warning when
the level of PO2 exceeds the maximum allowed limit of 1.60 ATA.
Variable Ascent Rate Indicator
The Variable Ascent Rate Indicator™ (VARI), located along the top of the
screen (Fig. 6), is provided to help you to avoid excessive ascent rates by pro-
viding a visual representation of ascent speed, rather than just showing that
you are ascending too fast. The Variable Ascent Rate Indicator has been
granted U.S. Patent no. 5,156,055.
The 5 triangular segments of the bar graph, located beside green, yellow, and
red reference zones, appear beginning from the left and may be considered an
ascent rate speedometer. Green is a 'normal' rate, yellow is a 'caution' rate,
and red is 'Too Fast'.
In the event that your ascent rate exceeds the maximum recommended rate of
60 feet (18 meters) per minute, the bar graph segments will enter the red zone
and all 5 segments will flash once per second until your ascent speed is slowed.
If this occurs, you should immediately slow your ascent.
Fig. 6 - Variable Ascent
Rate Indicator
Segments = Speed (rate)
0 = 0 - 20 fpm (0 - 6 mpm)
1 = 21 - 30 fpm (6.5 - 9 mpm)
2 = 31 - 40 fpm (9.5 - 12 mpm)
3 = 41 - 50 fpm (12.5 - 15 mpm)
4 = 51 - 60 fpm (15.5 - 18 mpm)
5 = 61+ fpm (18.5+ mpm)
(when 5, all will flash)
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
7
Data Plus 2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
O
2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
DIVE TIME REMAINING
One of the most important pieces of information on the Data Plus 2 is the pat-
ented Dive Time Remaining numeric display. To numerically display Dive Time
Remaining, the Data Plus 2 constantly monitors two critical pieces of informa-
tion; no decompression status and oxygen accumulation status. The Dive Time
Remaining display will indicate the time that is more critical for you at that par-
ticular moment (i.e.; whichever time is the least amount available of the two).
The time being displayed is identified by the No Decompression Dive Time icon
(Fig. 7a), or the O2 Time icon (Fig. 8a). This unique feature has been granted
U.S. Patent No. 4,586,136.
No Decompression Dive Time Remaining
No Decompression Dive Time Remaining is the maximum amount of time that
you can stay at your present depth before entering a decompression situation.
It is calculated based on the amount of nitrogen absorbed by twelve hypotheti-
cal tissue compartments. The rates each of these compartments absorb and re-
lease nitrogen is mathematically modeled and compared against a maximum al-
lowable nitrogen level. Whichever one of the twelve is closest to this maximum
level is the controlling compartment for that depth. Its resulting value will be
displayed numerically (Fig. 7b) along with the No Decompression Dive icon and
graphically as the Tissue Loading Bar Graph.
Fig. 7 - Dive Time Remaining
(No Deco Time is Less)
Fig. 8 - Dive Time Remaining
(O2 Accum Time is Less)
a
a
b
8
®
As you ascend from depth following a dive that has approached the no decom-
pression limit, the Tissue Loading Bar Graph will recede as control shifts to
slower compartments. This is a feature of the decompression model that is the
basis for multilevel diving, one of the most important advantages the Data
Plus 2 offers.
The no decompression algorithm is based upon Haldane’s theory using maxi-
mum allowable nitrogen levels developed by Merrill Spencer. Repetitive diving
control is based upon experiments designed and conducted by Dr. Ray Rogers
and Dr. Michael Powell in 1987. Diving Science and Technology
®
(DSAT), a
corporate affiliate of PADI
®
, commissioned these experiments.
Oxygen Accumulation Time Remaining
Oxygen accumulation (exposure) during a dive, or 24 hour period, appears
graphically as the Oxygen Accumulation (O2) Bar Graph. As time remaining
before reaching the oxygen exposure limit decreases, segments are added to
the O2 bar graph. When the amount of time remaining before reaching the
oxygen limit becomes less than the No Decompression Dive Time Remaining,
calculations for the current depth will be controlled by oxygen. Oxygen Time
Remaining will then appear as the main numeric time display (Fig. 9a) as sig-
nified by the O
2
Time icon appearing to the right of the display. As oxygen ac-
cumulation continues to increase, the O2 bar graph will enter the yellow Cau-
tion Zone (described later).
Fig. 9 - O2 Time Remaining
O
2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
a
9
Data Plus 2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
ALPHA/NUMERIC DISPLAYS
Depth Displays
During a dive, CurrentDepth and Maximum Depth reached during that
dive are displayed from 0 to 330 feet (99.5 meters) in 1 foot (.5 meter) incre-
ments (Fig. 10 a & b).
During a Decompression Dive, the required Ceiling Stop Depth is displayed
from 60 to 10 feet (20 to 3 meters) in 10 foot (3 meter) increments.
Time Displays (Fig. 10 c & d) are shown in hour:minute format (i.e., 1:02
represents one hour and two minutes, not 102 minutes!). The colon that sepa-
rates hours and minutes blinks once per second when the display is indicating
real time such as elapsed Surface Time, Elapsed Dive Time, or Time of Day.
Dive Time Available, Dive Time Remaining, Decompression Stop Time, Total
Ascent Time required, Time to Fly, or Desaturation Time are calculated pro-
jections of time and use a solid (non-blinking) colon to indicate that they are
counting down, rather than up.
Depth and Time displays will be illustrated and described in more detail as ap-
plicable for each of the operating modes.
Fig. 10 - Depth & Time
a
b
c
d
10
®
Ambient Temperatures from 0° to 99°F (-9 to 60°C) are displayed when the
Advance (Left) button is pressed while in the Surface Mode or in a dive mode.
BACKLIGHT FEATURE
In addition to using a high contrast LCD for easy readability in low light condi-
tions, the backlight features evenly illuminate the full display.
Smart Glo™, the surface mode backlight, senses the intensity of light that is
passing through the small ports located between the control buttons. If a low
level of light is sensed, the Smart Glo™ backlight will activate and illuminate
the display for button depression time plus 10 seconds when either button is
pressed.
Oceanglo
®
, the dive mode backlight, will illuminate the display for button de-
pression time plus 5 seconds when the Select (Right) control button is pressed.
Additional illumination time can be obtained by pressing the button again.
NOTE: Extensive use of the backlight reduces estimated bat-
tery life. The backlight will not activate during a 'low battery
condition', or when downloading data to a PC.
Responsible
11
Data Plus 2
OPERATING TEMPERATURE
The Data Plus 2 will operate in almost any temperature diving environment in
the world between 0 and 140 °F (-9 and 60 °C).
At extremely low temperatures, the LCD may become sluggish, but this will
not affect it's accuracy. If stored or transported in extremely low temperature
areas (below freezing), you should warm the module and its battery with body
heat before diving.
Even though the Data Plus 2 will operate in this wide range of temperatures,
it is possible to damage the electronics if left exposed to direct sun-
light, or in a hot confined space (like a car trunk). After the dive, cover
the Data Plus 2 and keep it out of the sun.
If inadvertently left in the direct sunlight for a long period, the LCD display
may become totally black. If this occurs, immediately immerse the Data Plus 2
in water. The display should recover its normal appearance after a few min-
utes.
Damage from excess heat, or cold, is not covered by the Data Plus 2
two year limited warranty.
Be a -
RESPONSIBLE DIVER
at all times.
R
E
S
P
O
N
S
I
B
L
E
D
I
V
E
R
12
®
WARNINGS and SAFETY RECOMMENDATIONS
• Inspect your Data Plus 2 prior to every dive, checking for any signs of the entrance of mois-
ture, damage to the housing, or damage to the LCD display. If these or other signs of dam-
age are found, return the unit to an Authorized Oceanic Dealer. DO NOT attempt to use it
until it has received factory service.
• Oceanic advocates responsible diving practices consistent with your individual level of for-
mal training and experience, and does not recommend decompression diving or diving below
130 feet (39 m).
• Always carry primary and backup dive lights when conducting dives that could include low
light situations.
• You should never, under any circumstances, swap your computer with another unit between
dives, or share your computer with another diver underwater. It is impossible for two divers
to stay precisely together underwater, and your computer's dive profile tracking of previous
dives will be pertinent to you only. Nitrogen and oxygen loading of a second user may be sig-
nificantly different and thus swapping dive computers could lead to inaccurate and poten-
tially dangerous predictions of decompression and oxygen accumulation status. This rule
applies to the use of all dive computers, but is especially important when using the
DataPlus2, due to the personal information it provides.
13
Data Plus 2
ACTIVATION
and
SETUP
refer to page 21 for - WARNINGS and SAFETY RECOMMENDATIONS
14
®
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
ACTIVATION
To activate the Data Plus 2, press the Select (Right) button once and release.
The Data Plus 2 will immediately enter Diagnostic Mode, displaying all “8’s”
(Fig. 11), followed by “dashes”, and a countdown from 9 to 0. While conduct-
ing diagnostics, the display is illuminated by the Smart Glo™ backlight as the
Data Plus 2 checks its display functions and battery voltage to ensure that ev-
erything is working correctly.
Upon activation, the Data Plus 2 will also check the ambient barometric pres-
sure, and calibrate its present depth as zero. At elevations of 2,000 ft. (610 m)
or higher, it will recalibrate itself to measure depth in feet of fresh water in-
stead of feet of sea water.
If no dive is made within 2 hours after initial activation, the Data Plus 2 will
automatically deactivate to conserve its battery power. Always check the
display before entering the water to ensure that it is activated.
SURFACE MODE
Surface Mode, identified by the Surface Time icon (Fig. 12a), immediately fol-
lows Diagnostic Mode after initial activation. Information displayed includes
the Dive Number '0' (no dive made yet) and Surface Time with flashing colon.
Fig. 11 - Diagnostic Mode
Fig. 12 - Surface Mode
a
O
2
M
FT
FT
MAX
M
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
15
Data Plus 2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
Fig. 13 - Low Battery
If battery voltage is below the level sufficient for a day's operation, the Battery
icon will be displayed, flashing (Fig. 13a). Below 15% of rated voltage, all
graphic displays will shut off except the Battery icon that will flash for 5 sec-
onds, then the unit will shutdown.
MAIN MODE MENU
While on the surface, you can access Temperature/Date/Time mode, FO2 Set
mode, Pre Dive Planning Sequence, Time to Fly/Desaturate, Log mode, and
Set mode. These are described later.
The menu structure of the Set Mode enables you to -
• turn the Dive Mode Alternate display feature On/Off.
• set Year/Month/Day
• select Hour Format (12 or 24 hour).
• set Hour/Minute.
• select the Dive Profile Sampling Rate (for PC download data).
• select Units of Measure (Imperial or Metric).
• turn the FO2 Default feature On/Off.
• initiate download of data (External Access).
Before going diving, enter settings that will be common for each of your dives
(e.g., Date, Time, Units of Measure, etc.). Setting the FO2 value for a nitrox
mix is a 'pre dive' setting that is entered before nitrox dives.
a
16
®
ENTERING SETTINGS
• The Advance (Left) button is used to gain access to settings.
• The Select (Right) button is used to toggle between, or scroll through, the
individual set points available for each of the settings.
• The Advance (Left) button is then used to accept and save the set point
and revert to Surface Mode, or continue to the next setting.
• See page 22 for a 'Summary of Access to Set Modes' that also
notes 'settings entered by the factory'.
NOTE: While in the Set Mode, if neither button is pressed, the
unit will automatically revert to Surface Mode in 2 minutes.
TO SET: ALTERNATE ON/OFF
'OFF' - Dive Modes will display Max Depth and Elapsed Dive Time
'ON' - Max Depth and Elapsed Dive Time are 'accessed' by pressing button
• press BOTH buttons simultaneously, while in Surface Mode
• 'Alt' appears with 'On', or 'Off', flashing (Fig. 14)
• press Select (Right) button to toggle between 'On' and 'Off'
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (this setting changed)
• advance to Set:Year (this setting not changed)
Fig. 14 - Set Alternate
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
17
Data Plus 2
TO SET: DATE//HOUR FORMAT//TIME
• press BOTH buttons simultaneously, while in Surface Mode
• press Advance (Left) button 1 time
• the Date appears with the Year setting flashing (Fig. 15a)
• press Select (Right) button until the correct Year appears
• press Advance (Left) button 1 time to accept the setting displayed
• the Month setting flashes (Fig. 15b)
• press Select (Right) button until the correct Month appears.
• press Advance (Left) button 1 time to accept the setting displayed
• the Day setting flashes (Fig. 15c)
• press Select (Right) button until the correct Day appears.
• press Advance (Left) button 1 time to accept the setting displayed
• the Hour Format appears flashing (Fig. 16)
• 12 Hr format = 12: Am to 11: Pm
• 24 Hr format = 0: to 23: (hours)
• press Select (Right) button to toggle between '12' and '24'
• press Advance (Left) button 1 time to accept the setting displayed
Fig. 16 - Set Hour Format
Fig. 15 - Set Date
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a
b
c
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
18
®
• the Time appears with the Hour setting flashing (Fig. 17a)
• press Select (Right) button until the correct Hour appears.
• press Advance (Left) button 1 time to accept the setting displayed
• the Minute setting flashes (Fig. 17b)
• press Select (Right) button until the correct Minute appears.
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (date/time settings changed)
• advance to Set: Sampling Rate (Date/Time settings not changed)
TO SET: SAMPLING RATE
Sampling Rate is the Time, or Depth, interval at which data samples will be
recorded for subsequent download to the OceanLog™ PC software program. It
has 'no effect' upon displayed data or data stored in the unit's viewable Log.
Rates available are 2 FT (.5M), 5 FT (1.5 M), 10 FT (3 M), 2 SEC, 5 SEC, 10
SEC, 15 SEC, 20 SEC, 25 SEC, 30 SEC. Lower rates = more samples and
more memory used per dive (e.g., fewer dives stored for download).
• press BOTH buttons simultaneously, while in Surface Mode
• press Advance (Left) button 7 times
• the Rate setting appears flashing (Fig. 18)
Fig. 17 - Set Time
Fig. 18 - Set Sampling Rate
M
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a
b
19
Data Plus 2
• press Select (Right) button until the desired Rate appears.
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (this setting changed)
• advance to Set: Unit (this setting not changed)
TO SET: UNITS OF MEASURE
• press BOTH buttons simultaneously, while in Surface Mode
• press Advance (Left) button 8 times
• the Units of Measure icons appear flashing (Fig. 19)
• press Select (Right) button to toggle between 'Imperial' (FT/°F) and
'Metric' (M/°C)
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (this setting changed)
• advance to Set: FO2 Default (this setting not changed)
TO SET: FO2 50% DEFAULT ON/OFF
'Off' - FO2 value set point remains at % set
'On' - FO2 value set point reverts to 50% after dives
(The FO2 Default feature is described on page 25.)
Fig. 19 - Set Units
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
20
®
• press BOTH buttons simultaneously, while in Surface Mode
• press Advance (Left) button 9 times
• FO2 50 appears with On or Off flashing (Fig. 20)
• press Select (Right) button to toggle between 'On' and 'Off'
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (this setting changed)
• advance to EA Mode (this setting not changed)
EA MODE
External Access (EA) Mode (described on page 42) is accessed only when data
is being downloaded.
• press Advance (Left) button to bypass EA Mode (Fig. 21) and revert to
Surface Mode
Fig. 21 - EA Mode
Fig. 20 - Set FO2 Default
Responsible
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
21
Data Plus 2
WARNINGS and SAFETY RECOMMENDATIONS
• Never activate the Data Plus 2 underwater. This may result in inaccurate depth and no-de-
compression time displays. If the unit is activated when deeper than 4 feet (1 meter) under-
water, or at elevations higher than 14,000 feet (4,267 meters), it will perform a diagnostic
check followed by immediate shutdown.
• During activation and diagnostics, if any display or function varies from the information
presented here, return the Data Plus 2 to your Oceanic Dealer for inspection.
• If a Low Battery condition is indicated following diagnostics, Oceanic strongly recommends
that you DO NOT dive until the battery is replaced.
R
E
S
P
O
N
S
I
B
L
E
D
I
V
E
R
22
®
SUMMARY OF ACCESS TO SET MODES
(settings entered by the factory appear in italics)
To access a specific Set mode from the Surface Mode, press the button(s) as follows:
SET MODE TO ACCESS TOVIEW TO SAVE
To access> Both '1' time>
• Alternate Display (Off) Left '0' time> Right - toggle (On/Off)> Left - to Surface* or Year
• Year (1999) Left '1' time> Right - 1 year/second> Left - to Month
• Month (1) Left '2' times> Right - 1 month/second> Left - to Day
• Day (1) Left '3' times> Right - 1 day/second> Left - to Hour Format
• Hour Format (12) Left '4' times> Right - toggle 12/24> Left - to Hour
• Hour (12) Left '5' times> Right - 1 hour/second> Left - to Minute
• Minute (00) Left '6' times> Right - 1 minute/second> Left - to Surface* or Rate
• Sample Rate (10 FT/3 M) Left '7' times> Right - 1 rate/second> Left - to Surface* or Units
• Units (Imperial/Metric) Left '8' times> Right - toggle> Left - to Surface* or Default
• FO2 Default (On) Left '9' times> Right - toggle (On/Off)> Left - to Surface* or EA
• EA (download) Left '10' times> Left - to Surface
* If the setting was altered
23
Data Plus 2
PRE DIVE
and
DIVE MODES
refer to page 34 for - WARNINGS and SAFETY RECOMMENDATIONS
24
®
OPERATIONAL MODES
While on the surface the Interactive Control Console enables you to access six
operational modes and activate the backlight. During a dive it enables you to
view 'alternate' displays of information and activate the backlight.
TEMPERATURE/DATE/TIME MODE
To view Ambient Temperature/Date/Time (Fig. 22) while in Surface Mode:
• press the Advance (Left) button 1 time
• During low light conditions, the Smart Glo™ backlight will illuminate the
display for button depression time plus 10 seconds.
• The unit reverts to Surface Mode after 10 seconds, unless the Advance
(Left) button is pressed to access FO2 Mode.
Set for Imperial units of measure, Month is on the left and Day on the right.
Set for Metric, Day is on the left and Month on the right. Year doesn't appear.
FO2 MODE
The Data Plus 2 can be used either as an Air computer or as a Nitrox com-
puter. After activation, it will operate as an Air computer without displaying
information associated with oxygen calculations, unless it is set for a percent-
age of oxygen (FO2) other than Air (numerical value between 21 and 50 %).
Fig. 22 - Temperature/
Date/Time
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
25
Data Plus 2
FO2 50% Default
If the Default is set to 'On' and FO2 is set to a value 'greater than 21%', the
FO2 value will automatically revert to 50% 10 minutes after that dive.
• FO2 must be reset for each repetitive nitrox dive, or the value will auto-
matically 'default' to 50 (Fig. 23) and the dives will be calculated based on
50% O2 for oxygen calculations and 21% O2 (79% nitrogen) for nitrogen
calculations.
• If you surface for greater than 10 minutes during a dive, a subsequent
descent will be considered a new dive and the FO2 value must be reen-
tered.
If the Default is set to 'Off', the FO2 value for repetitive dives remains the
same until the FO2 set point is manually changed.
FO2 Set for an Air Dive
When set with an FO2 value of 'Air', the Data Plus 2 will perform calculations
the same as if FO2 were set for 21% oxygen, internally accounting for oxygen
loading for any subsequent Nitrox dives. However, oxygen related displays,
warnings, and the O2 Bar Graph will not appear on the display for that dive
(Fig. 24), or subsequent dives, unless FO2 is set for a numerical value (21 to
50%).
Fig. 24 - FO2 'Air'
Fig. 23 - FO2 Default
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
26
®
Fig. 25 - Setting FO2
Setting FO2
To access FO2 Mode while in the Surface Mode and set the unit for Air or the
percentage (%) of oxygen (FO2) in your nitrox mix:
• press the Advance (Left) button 2 times
• press the Select (Right) button, repeatedly or press and hold, until the
value of FO2 for the nitrox mix being used is displayed
• the FO2 value displayed (Fig. 25a) will advance from 21 to 50 (%) in in-
crements of 1 (%), then display 'Air' again.
• the Maximum Depth that can be achieved with an oxygen partial pres-
sure (PO2) of 1.60 ATA will be displayed (Fig. 25b) for each FO2 value.
No value will appear for Air.
The unit reverts to Surface Mode after 2 minutes, unless the Advance (Left)
button is pressed to access the Pre Dive Planning Sequence.
FO2 Set for a Nitrox Dive
You can set the Data Plus 2 for nitrogen-oxygen (nitrox) mixtures of 21% to
50% oxygen (O2). If FO2 is set at a value of 21% (Fig. 25), the unit will remain
set as a '21% nitrox computer' for subsequent nitrox dives until FO2 is set to a
higher value, or until it automatically turns off and is reactivated.
Fig. 26 - FO2 21%
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
a
b
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
27
Data Plus 2
Once a dive is made with the Data Plus 2 set as a nitrox computer (FO2 set for
a numerical value), it cannot be set for 'Air' until 24 hours after the last nitrox
dive. However, you can set FO2 for 21% for use with air.
PRE DIVE PLANNING SEQUENCE™
Oceanic strongly recommends that you review the Pre Dive Planning
Sequence (PDPS) prior to every dive to help you plan your dive as re-
quired to avoid exceeding no decompression or oxygen exposure lim-
its. This is especially important for repetitive dives, when the Pre Dive Plan-
ning Sequence (Fig. 27) will indicate for you the no decompression dive times
that are available to you on your next dive, based on any residual nitrogen or
oxygen accumulation (whichever is in control) following your last dive and sur-
face interval.
To access the Pre Dive Planning Sequence while in the Surface Mode:
• press the Advance (Left) button 3 times
• press the Select (Right) button, repeatedly or press and hold
• a sequence of depths from 30 to 160 feet (9 to 48 meters) in 10 foot (3
meter) increments will be displayed
The unit reverts to Surface Mode 2 minutes after the Select (Right) button is
released, unless the Advance (Left) button is pressed to access the Log Mode.
Fig. 27 - Pre Dive
Planning Sequence
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
28
®
With each depth display, you will see either 'predicted' no decompression limits
based upon your previous dive profiles (if calculated to be nitrogen controlled),
or 'predicted' oxygen tolerance limits based upon either a single dive oxygen
dose or your 24 hour accumulation of oxygen (if calculated to be oxygen con-
trolled).
No decompression times are only displayed for depths where there is at least 3
minutes of dive time available at that depth, taking into account a descent rate
of 120 feet (36 meters) per minute. Depths greater than the maximum depth
that can be achieved with a partial pressure of oxygen (PO2) of 1.60 ATA will
not be displayed.
Prior to a Repetitive Nitrox Dive
If the segments of the Tissue Loading Bar Graph
are displayed (Fig 28) dur-
ing the Pre Dive Planning Sequence, that next dive is calculated to be con-
trolled by nitrogen loading.
If the segments of the O2 bar graph are displayed (Fig. 29), that next dive is
calculated to be controlled by oxygen loading.
The Data Plus 2 will store oxygen accumulation for up to 10 dives conducted
during a 24 hour period. In the event that the maximum limit for oxygen load-
ing has been exceeded for that day, all of the segments of the O2 bar graph will
Fig. 29 - Oxygen Control
Fig. 28 - Nitrogen Control
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
29
Data Plus 2
be displayed flashing (Fig. 30). Depth and Time displays will not appear until
the O2 bar graph recedes into the green (normal) zone (e.g., your daily oxygen
dosage decreases an amount equivalent to the amount accumulated during the
latest dive completed).
NO DECOMPRESSION DIVE MODE
As long as it is activated on the surface, the Data Plus 2 will enter the No De-
compression Dive Mode when you descend deeper than 5 feet (1.5 meters), re-
gardless of the operating mode it is in. If activated below 4 feet (1 meter), the
unit will perform a diagnostic check and shutdown.
To activate the Oceanglo
®
backlight underwater, press the Select (Right) but-
ton. The display will be illuminated for button depression time plus 5 seconds.
It will not activate if a Low Battery condition exists.
Main Display (data shown depends on Alternate ON/OFF setting)
If the Alternate Display is set to 'OFF', information includes (Fig. 31) -
Current Depth, Elapsed Dive Time (and icon), Dive Time Remaining (and
icon), and Maximum Depth for that dive (and icon).
Fig. 31 - Main Display
(Alternate Off)
Fig. 30 - O2 Limit Exceeded
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
30
®
If the Alternate Display is set to 'ON', information includes (Fig. 32):
Current Depth and Dive Time Remaining (and icon). Elapsed Dive Time and
Maximum Depth are 'accessed' in Large Format, as described below.
Secondary Display (access if Alternate is set ON or OFF)
To view water Temperature, Time of Day, and if FO2 was set for a numerical
value, display the current level of PO2 (Fig. 33):
• press the Advance (Left) button 1 time
• the unit will revert to the Main Display after 10 seconds, if the Advance
(Left) button is not pressed again.
Alternate Display (access only if Alternate is set ON)
To view Maximum Depth and Elapsed Dive Time in Large Format in place of
Current Depth and Dive Time Remaining (Fig. 34):
• press the Advance (Left) button 2 times, or -
• press the Advance (Left) button 1 time, if viewing Temp/Time/PO2.
• the unit will revert to the Main Display after 10 seconds, or if the Ad-
vance (Left) button is pressed.
The Graphic Diver Interface (bar graphs) will be active with each display
representing nitrogen loading, oxygen accumulation (if FO2 was set for a value
other than Air), and your ascent rate.
Fig. 32 - Main Display (Alt On)
Fig. 34 - Alternate Display
Fig. 33 - Secondary Display
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
FT
MAX
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
31
Data Plus 2
DECOMPRESSION DIVE MODE
The Data Plus 2 provides information that will help you avoid, or if necessary,
manage emergency decompression.
The Decompression Dive Mode activates when the Tissue Loading Bar Graph
enters the red 'DECO' zone (Fig. 35a).
VIOLATION MODES
The Data Plus 2 enters Violation Modes when it is unable to predict an ascent
procedure.
GAUGE MODE
If the Data Plus 2 enters a Permanent Violation Mode, it will not display infor-
mation relating to nitrogen or oxygen loading for the remainder of that dive or
for subsequent dives conducted during the 24 hour period after surfacing.
NOTE: Decompression Dive Mode, Violation Modes, and Gauge
Mode are described later on pages 46 - 52.
Fig. 35 - Entering Into
Decompression Mode
a
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
32
®
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
ASCENDING TO THE SURFACE
While ascending to shallower depths, the segments that have filled up the Tis-
sue Loading Bar Graph will begin to recede (Fig. 36), offering a graphic repre-
sentation of your multilevel diving capability. By 'backing off' on the bar graph
(fewer segments), you can establish a personal level of conservatism and mar-
gin of protection.
If you entered Decompression Mode, you must not complete your ascent until
the Tissue Loading Bar Graph is at least inside the yellow Caution Zone.
If you have not entered Decompression Mode, a safety stop made be-
tween 15-20 feet (5-6.5 meters) is strongly recommended as a stan-
dard procedure before completing your ascent.
You should make every effort to complete all of your ascents with the Tissue
Loading Bar Graph inside of the green zone.
While you cannot provide a guarantee against the occurrence of de-
compression sickness, you may choose your own personal zone of
caution based upon your individual age, physique, excessive weight,
training, experience, etc. to reduce the statistical risk.
Fig. 36 - Tissue Loading Bar
Graph (receding)
33
Data Plus 2
The Variable Ascent Rate Indicator™ shows how fast you are ascending.
When you exceed the maximum recommended ascent rate of 60 feet per
minute (18 meters per minute), the bar graph will enter the red (Too Fast)
zone (Fig. 37a). You will be alerted by all segments of the bar graph flashing.
The flashing will stop when your ascent rate is slowed.
ALTITUDE DIVING
The mathematical model within the Data Plus 2 accounts for the reduced No
Decompression dive time available at higher elevations based on NOAA (Na-
tional Oceanic and Atmospheric Administration) guidelines. When diving in
high altitude lakes or rivers from 2,000 to 14,000 feet (610 to 4,268 meters),
the Data Plus 2 will adjust automatically, providing corrected depth and re-
duced No Decompression and Oxygen Exposure times.
Also, when above 2,000 feet (610 meters), depth calibration is automatically
changed to read in feet of freshwater rather than feet of seawater. If activated
above 14,000 feet (4,268 meters), the unit will perform a diagnostic check and
shutdown.
Fig. 37 - Ascent 'Too Fast'
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
a
34
®
WARNINGS and SAFETY RECOMMENDATIONS
• The percentage of oxygen (FO2) in the nitrox mix being used must be set 'before each' nitrox
dive, unless the FO2 50% Default is set to 'Off'.
• The Pre Dive Planning Sequence provides predicted times for subsequent dives. Depending
on cylinder size, breathing gas consumption, and oxygen accumulation you may have less
time available than indicated because of breathing gas quantity or other limitations.
• The Data Plus 2 must be manually activated and be in an operating mode prior to start of a
dive. The unit will not activate automatically by immersion in water.
• Every effort should be made to keep each of the bar graphs in the green throughout your
dives to reduce your risk of exposure to decompression sickness and oxygen toxicity.
• Until it has shut itself off, you must not use the Data Plus 2 at a different altitude than the
altitude where it was originally activated. Doing so will result in an error equal to the dif-
ference in barometric pressure, and possibly a false dive mode with erroneous data.
35
Data Plus 2
POST
DIVE
MODES
refer to page 43 for - WARNINGS and SAFETY RECOMMENDATIONS
36
®
FIRST 2 HOURS AFTER A DIVE
When you ascend to 3 feet (1 meter) or shallower, the Data Plus 2 will enter
Surface Mode (Fig. 38) and begin counting your surface interval.
TRANSITION PERIOD
The first 10 minutes is, in affect, a Transition Period during which time the
following information is displayed (Fig. 38):
• Surface Mode icon (flashing).
• 'Number' of that dive
• Surface Interval (colon flashing).
• Tissue Loading Bar Graph indicating current nitrogen loading.
• O2 Bar Graph indicating current oxygen loading (if a nitrox dive)
If you descend during the 10 minute transition period, time underwater will be
considered a continuation of that dive. The time at the surface (if less than 10
minutes) will not be added as Elapsed Dive Time.
To view the Temperature/Date/Time (Fig. 39):
• press the Advance (Left) button 1 time
• the unit will revert to Surface Mode after 10 seconds, if no button is
pressed
Fig. 39 - Temperature/
Date/Time
Fig. 38 - Post Dive
Surface Mode (<10 min)
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
37
Data Plus 2
To view that Dive's Log (during the Transition Period):
• press the Advance (Left) button 2 times, or -
• press the Advance (Left) button 1 time, if viewing Temperature/Date/
Time
• the unit will revert to Surface Mode after 2 minutes, if no button is
pressed
Data will not be stored in the unit's memory until the 10 minute Transition
Period is completed.
Once 10 minutes have elapsed, that dive and transition period are completed,
and a subsequent descent will be considered a new dive.
AFTER THE TRANSITION PERIOD
For the remainder of the first 2 hours after surfacing the information de-
scribed above will continue to be displayed as the Surface Mode (Fig. 40) and
you will have full access to other modes.
To view the Temperature/Date/Time:
• press the Advance (Left) button 1 time
• the unit will revert to Surface Mode after 10 seconds, if no button is
pressed
Fig. 40 - Surface Mode
(first 2 hours)
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
38
®
To access FO2 Mode:
• press the Advance (Left) button 2 times (while in Surface Mode)
• If the FO2 Default was set OFF, the FO2 setting displayed will be the
same value previously set (Fig. 41).
• If the FO2 Default was set ON, the FO2 value displayed (Fig. 42) will be
the 'default value' of 50 (%) and will have the be set for the beathing gas
used for the next dive.
• press the Select (Right) button to alter the setting, if required.
• the unit reverts to Surface Mode after 2 minutes, unless the Advance
(Left) button is pressed to access the Pre Dive Planning Sequence.
To access Pre Dive Planning Sequence™:
• press the Advance (Left) button 3 times (while in Surface Mode)
• press the Select (Right) button to scroll through the sequence
• The unit reverts to Surface Mode after 2 minutes, unless the Advance
(Left) button is pressed to access the Fly Mode.
The Pre Dive Planning Sequence will now show 'adjusted' No Decompression
Limits (Fig. 43) based on residual nitrogen calculated to be remaining from the
previous dives. Calculated dive times and the maximum allowed depth dis-
played will increase as the real time surface interval increases after completion
of a dive.
Fig. 41 - FO2 (Default OFF)
Fig. 43 - Adjusted NDLs
Fig. 42 - FO2 (Default ON)
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
39
Data Plus 2
The Pre Dive Planning Sequence will only scroll to the maximum depth al-
lowed by the nitrogen or oxygen limit, whichever is in control. The respective
bar graph will be displayed to indicate which is in control.
To access Time to Fly and Desaturate Countdowns:
• press the Advance (Left) button 4 times (while in Surface Mode)
• The unit reverts to Surface Mode after 2 minutes, unless the Advance
(Left) button is pressed to access the Log Mode.
The Time To Fly counter begins counting down 10 minutes after the last dive
has ended (after the 10 minute Transition Period) displaying the word 'FLY'
with a countdown (Fig. 44a) that starts at 23:50 (hr:min) and counts down to
0:00 (hr:min).
The Time to Desaturate counter (Fig. 44b) provides calculated time for tissue
desaturation at sea level. The countdown starts 10 minutes after the dive at
9:59 (hours:minutes) maximum and counts down to 0:00. If the time is calcu-
lated to be greater than 9:59, the display will indicate 9:- - (Fig. 45a) until it
decreases to 9:59.
If a violation occurred during the dive, Time to Desaturate will not be dis-
played and a single dash ( - ) will appear (Fig. 46a) instead of the letters FLY.
The time shown is only time until the unit will resume normal operation.
Fig. 44 - Time to Fly/Desaturate
Fig. 46 - After Violation
Fig. 45 - Desaturate (>9:59)
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a
b
a
a
40
®
LOG MODE
Information from your 12 latest dives is stored in the Log for viewing. After
12 dives are accumulated, each subsequent dive will overwrite the oldest dive
in the log (i.e., the most recent dive deletes the oldest). Log information will
not be lost when batteries are removed, but factory service will delete the logs.
Dives are displayed in a reverse sequence that starts with the dive most re-
cently recorded back to the oldest of the 12 dives stored. Thus, your most re-
cent dive will always be the first shown in the sequence. Each dive has three
log screens - Date/Time started, Nitrogen data, and Oxygen data.
Dives are identified by the Date/Time and number. The first dive of a new day
(after midnight) will be #1.
The Advance (Left) button is used to access each dive's log.
The Select (Right) button is used to view second and third screens for that dive
(Nitrogen and Oxygen related data).
To access the Log Mode:
• press the Advance (Left) button 5 times (while in Surface Mode)
• the first screen (Fig. 47) of the most recent dive will appear
• Log Mode icon and Dive Number
• Date and Time of Day that the dive started (and icon)
Fig. 47 - Log Mode
(first screen - date/time)
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
41
Data Plus 2
To access a specific dive's log, press the Advance (Left) button repeatedly.
To view the second screen (Nitrogen Log) for that dive (Fig. 48):
• press the Select (Right) button 1 time
• Log Mode icon
• Dive number
• Maximum Depth reached for the dive (and icon)
• Elapsed Dive Time (and icon)
• Surface Interval prior to that dive (and icon)
• Variable Ascent Rate Indicator - showing the maximum ascent rate
maintained for 4 consecutive seconds during the dive
• Tissue Loading Bar Graph - showing tissue nitrogen loading at the
end of the dive
To view the third screen (Oxygen Log) for that dive Fig. 49):
• press the Select (Right) button 1 time
• Log Mode icon
• FO2 value - set for that dive (and 'FO2' symbol)
• Maximum PO2 level - reached during that dive (and 'PO2' symbol)
• O2 bar graph - showing oxygen loading at the time you surfaced.
• If FO2 was set for 'Air', the O2 screen will only display 'FO2' and 'Air'.
• press the Select (Right) button 1 time to view the first screen of the previ-
ous dive's log, or press the Advance (Left) button repeatedly to revert to
the Surface Mode.
Fig. 48 - Log Mode
(second screen - nitrogen)
Fig. 49 - Log Mode
(third screen - oxygen)
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
O
2
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
42
®
To exit Log Mode and return to the Surface Mode (at any time):
• press the Advance (Left) button repeatedly to proceed through the re-
maining recorded dives.
• the unit will automatically revert to Surface Mode after 2 minutes, if no
button is pressed
AFTER THE FIRST 2 HOURS
Two hours after the last dive the Surface Mode will no longer be displayed.
The Time to Fly and Desaturate countdown timers will be displayed con-
tinuously, giving the final countdowns from 22:00 and 9:xx to 0:00 (Fig. 50).
To access other modes or enter settings:
• press the Select (Right) button to enter Surface Mode
• the unit will revert to Fly Mode after 2 hours, if no button is pressed
DOWNLOADING DATA TO PC
Using special infrared linking hardware and a unique PC software program,
data from your dives can be downloaded (copied) from your Data Plus 2 into an
IBM compatible PC program running on a Windows
®
95 or 98 operating sys-
tem. Instructions for performing the interface and download are provided
with the OceanLog™ for Data Plus 2 hardware and software package. The
OceanLog™ program provides profile data sampled throughout the dive.
Fig. 50 - Display
(after 2 hours on surface)
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
43
Data Plus 2
To access the External Access (EA) Mode:
This mode is used only to download data to the Oceanlog™ PC software program.
• press both buttons simultaneously (while in Surface Mode)
• press the Advance (Left) button 10 times
• the letters EA appear, flashing (Fig. 51)
• press the Advance (Left) button to revert to Surface Mode, or -
• press the Select (Right) button to initiate download
• the unit will automatically revert to Surface Mode after download is com-
plete, or in 2 minutes if no button is pressed
• the backlight will not operate upon entering EA Mode or when download is
initiated
Fig. 51 - EA Mode
WARNING and SAFETY RECOMMENDATION
• The longer you wait to fly (or travel to higher elevations) after diving, the more you will re-
duce your exposure to decompression sickness.
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
44
®
SUMMARY OF ACCESS TO POST DIVE MODES
During the first 2 hours after a dive* (after the 10 minute Transition Period has ended):
MODES TO ACCESS TO VIEW
Backlight press Either '1 time'
(if low light level is sensed)
Temperature/Date/Time press Left '1 time'
FO2 set press Left '2 times' > press Right (hold or repetitive)
Pre Dive Plan Sequence press Left '3 times' > press Right (hold or repetitive)
Fly/Desaturate press Left '4 times'
Log Mode press Left '5 times' > press Right (hold or repetitive)
Set Mode press Both '1 time' > Refer to page 22 of this Guide
EA Mode press Both '1 time' > press Left '10 times' > Right '1 time'
*After the First 2 Hours, the unit will remain in Fly/Desaturate Mode. To access other Modes:
• press the Right button to return to the Surface Mode, then press the buttons as indicated above.
45
Data Plus 2
HANDLING
THE
EXTREMES
refer to pages 56-58 for - WARNINGS and SAFETY RECOMMENDATIONS
46
®
AVOIDING AND MANAGING DECOMPRESSION
The Data Plus 2 is a sophisticated instrument designed with capabilities that
go beyond the range of recreational diving with compressed air. It will help
you to avoid and, if necessary, manage decompression.
TISSUE LOADING BAR GRAPH
The Tissue Loading Bar Graph offers you a convenient way to consistently
monitor how close you are coming to the No Decompression Limit. As you use
the Data Plus 2 and become familiar with the Tissue Loading Bar Graph, you
will notice that it displays fewer segments for shorter dive times and shallower
depths. Use this feature to adjust conservatism to your diving needs.
Use the yellow Caution (C.Z.) Zone (Fig. 52a) as a visual reference to
place a wider margin of protection between you and the No Decom-
pression Limit.
Oceanic suggests keeping the Tissue Loading Bar Graph in the green No De-
compression (NO DECO) zone during all of your dives, and that it be in the
green when leaving the water.
Fig. 52 - Caution Zone
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
a
47
Data Plus 2
DECOMPRESSION DIVE MODE
The Data Plus 2 is designed to help you by providing a complete representa-
tion of how close you are to entering decompression. Decompression Dive
Mode activates when theoretical no decompression time/depth limits are ex-
ceeded.
In the event that you enter Decompression Mode, as indicated by the large red
segment of the Tissue Loading Bar Graph (Fig. 53a) and flashing ceiling bar of
the Decompression Mode icon, immediately begin a safe controlled ascent to a
depth slightly deeper than, or equal to, the Required Ceiling Stop Depth indi-
cated (Fig. 53b) and decompress for the Stop Time indicated (Fig. 53c).
Main Display (data shown is the same if Alternate is set ON or OFF)
Information displayed in addition to Stop Depth/Time includes:
• current Depth
• Total Ascent Time (Fig. 53d) - that includes stop times required at all
ceilings and vertical ascent time calculated at 60 ft (18 m) per minute.
• O2 bar graph (if a nitrox dive) and Variable Ascent Rate Indicator - con-
tinue to represent their respective information
Additional data can be accessed using the Advance (Left) button, and the
Oceanglo
®
backlight can be activated using the Select (Right) button.
Fig. 53 - Main Display
(Alternate set ON or OFF)
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
b
c
a
d
48
®
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
Secondary Display (access if Alternate is set ON or OFF)
To view water Temperature, Time of Day, and if FO2 was set for a numerical
value, display the current level of PO2 (Fig. 54):
• press the Advance (Left) button 1 time
• the unit will revert to the Main Display after 10 seconds if the Advance
(Left) button is not pressed again.
Alternate Display (access only if Alternate is set ON)
To view Elapsed Dive Time and Maximum Depth in Large Format in place of
Current Depth and Dive Time Remaining (Fig. 55):
• press the Advance (Left) button 2 times, or -
• press the Advance (Left) button 1 time, if viewing Temp/Time/PO2.
• the unit will revert to the Main Display after 10 seconds, or if the Ad-
vance (Left) button is pressed.
MANAGING DECOMPRESSION STOPS
The amount of decompression credit time that you receive is dependent on
depth, with slightly less credit given the deeper you are. You should stay
slightly deeper (Fig. 56a) than the Required Stop Depth indicated (Fig. 56b)
until the next shallower Stop Depth appears. Then, you can slowly ascend to,
but not shallower than, that indicated ceiling Stop Depth.
Fig. 56 - Managing a Stop
b
a
Fig. 54 - Secondary Display
Fig. 55 - Alternate Display
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
FT
MAX
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
49
Data Plus 2
Once all required decompression has been completed, the Data Plus 2 will
switch to the No Decompression Dive Mode. This is indicated by Total Ascent
Time = 0:00, and the Tissue Loading Bar Graph receding into the yellow Cau-
tion Zone. Time Dive Remaining now appears in place of Total Ascent Time .
VIOLATION MODES
It is important to understand each different Violation Mode and how to carry
out emergency procedures in the event you enter one.
While in Violation Modes, the Secondary and Alternate displays previously de-
scribed can be accessed using the Advance (Left) button, and the Oceanglo
®
backlight can be activated using the Select (Right) button.
CONDITIONAL VIOLATION MODE
The Data Plus 2 will enter Conditional Violation Mode if you ascend shal-
lower (Fig. 57a) than the required decompression ceiling indicated by
the Required Stop Depth displayed (Fig. 57b). The Total Ascent Time
display (Fig. 57c) will flash until you descend below the Required Stop Depth.
If you descend below the required decompression ceiling before 5 minutes have
elapsed, the Data Plus 2 will continue to function as if no violation had oc-
curred. In this case, no off-gassing credit will be given, and for each minute
Fig. 57 - Conditional
Violation
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a
b
c
50
®
above the ceiling 1
1
/
2
minutes of penalty time is added to Required Stop Time.
The added penalty decompression time will have to be 'worked off' first, before
obtaining off-gassing credit. Once the penalty time is worked-off, and off-gas-
sing credit begins, required decompression Stop Depths and Time will decrease
toward zero, then the Tissue Loading Bar Graph will recede into the caution
zone and the Data Plus 2 will revert to the No Decompression Dive Mode.
DELAYED VIOLATION MODE
Three conditions cause the Data Plus 2 to enter the Delayed Violation Mode:
1. You remain above the required Decompression Ceiling Stop Depth
for 'more than 5 minutes' (Fig. 58). You would then need to follow the
Stop Depths and Times toward the surface as the Tissue Loading Bar Graph
recedes into the caution zone.
2. Your decompression requires a ceiling Stop Depth 'between' 60
feet (18 meters) and 70 feet (21 meters). In this situation the Tissue
Loading Bar Graph will flash (Fig. 59). Total Ascent Time needed to get back
to the surface will still be displayed.
You must ascend to just deeper than 60 feet (18 meters) staying as close to 60
feet (18 meters) as possible without causing the Total Ascent Time display to
Fig. 59 - Delayed Violation
(Required Stop >60FT/18M)
Fig. 58 - Delayed Violation
(> 5 minutes above Stop)
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
51
Data Plus 2
flash. When the Required Stop Depth indicates 50 FT/ 15 M, 40 FT/ 12 M, 30
ft/ 9 M, 20 FT/ 6 M, then 10 FT/ 3 M, you can ascend to, but no shallower than
those depths and continue decompressing.
The Data Plus 2 cannot accurately calculate decompression times for Stop
Depths much greater than 60FT (18M) and offers no indication of how much
time spent underwater would result in the need for greater than a 60 FT (18
M) decompression stop depth.
3. You descend deeper than 330 feet (99.5 meters). Upon descending
deeper than 330 feet (99.5 meters), the Tissue Loading Bar Graph will flash
and the Current Depth and Maximum Depth displays will only indicate (Fig.
60) 3 dashes (- - -) until ascent is made to a depth shallower than 330 feet (99.5
meters), at which time the Current Depth display will be restored. Max Depth
will continue to display 3 dashes.
IMMEDIATE VIOLATION MODE
Five minutes after reaching the surface from a dive in which a Delayed Viola-
tion occurred, the Data Plus 2 will enter an Immediate Violation Mode.
If a ceiling much greater than 60FT (18M) is required, an Immediate Violation
Mode (Fig. 61) will be entered. This situation would be preceded by entering
Delayed Violation Mode, previously described. The Data Plus 2 would then
Fig. 61 - Immediate Violation
(Alternate set OFF)
Fig. 60 - Delayed Violation
(deeper than 330ft/99.5m)
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
52
®
operate with limited functions (Current Depth, Max Depth, and Elapsed Dive
Time) in Gauge Mode during the remainder of that dive and for 24 hours after
surfacing.
GAUGE MODE
Underwater, the Gauge Mode (Fig. 62) is a continuation of the Immediate Vio-
lation Mode that turns the Data Plus 2 into a digital instrument. Dive Time
Remaining will not be displayed and the Tissue Loading Bar Graph and O2
Bar Graph will flash as a warning of this condition.
After surfacing, Gauge Mode does not provide the FO2, Pre Dive Planning Se-
quence, or Time to Fly features. The countdown timer that appears (Fig. 63)
10 minutes after the dive at 23:50 (hr:min) does not represent Time to Fly. It
is only provided to inform you of the time remaining before normal Data Plus
2 operation can resume with full features and functions.
PERMANENT VIOLATION
Entering the Immediate Violation Mode, then Gauge Mode, will result in loss
of all Data Plus 2 decompression and oxygen monitoring functions for 24 hours
after that dive. This condition is considered a Permanent Violation. If a dive
is made during the 24 hour period, a 'full 24 hour surface interval' must be
served before all functions are restored.
Fig. 63 - Gauge Mode
(surface)
Fig. 62 - Gauge Mode
(underwater - Alt set OFF)
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
53
Data Plus 2
EXCEEDING MAXIMUM OPERATING DEPTH
The maximum depth the Data Plus 2 will display all of its features is 330 feet
(99.5 meters). Upon exceeding 330 feet (99.5 meters), the Tissue Loading Bar
Graph will flash, and the Depth and Maximum Depth displays will only indi-
cate 3 dashes (- - -) signifying that you are 'out of range' (Fig. 64). The numeric
display for Current Depth will reappear when you ascend shallower than 330
feet (99.5 meters). For the remainder of that dive, and in the log for that dive,
only 3 dashes will be displayed as the value for Maximum Depth.
OXYGEN EXPOSURE
The Data Plus 2 is a sophisticated instrument designed with capabilities that
go beyond the range of recreational diving with compressed air. It will help
you to avoid and manage excessive oxygen exposure.
PARTIAL PRESSURE OF OXYGEN
As depth increases during the dive, the partial pressure of oxygen (PO2) in-
creases.
To view the current value of PO2 (Fig. 65a):
• press the Advance (Left) button 1 time to access the Secondary Display.
Fig. 65 - Current PO2
(secondary display)
Fig. 64 - Out of Range
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a
54
®
HIGH PO2 DIVE MODE
The Data Plus 2 enters the High PO2 Dive Mode when partial pressure of oxy-
gen becomes equal to, or greater than, 1.40 ATA. The current PO2 value and
the symbol 'PO2' will appear in the center portion of the display (Fig. 66). If
the Alternate Display is set to ON, they replace Max Depth and Elapsed Dive
Time. They will remain on display until partial pressure of oxygen decreases
below a value of 1.40 ATA.
If partial pressure of oxygen continues to increase, the value of PO2 displayed
will increase from 1.40 ATA toward a maximum value of 5.00 ATA in incre-
ments of '.01' ATA. When PO2 reaches a value of 1.60 ATA, the large red seg-
ment of the O2 bar graph, the PO2 value, and PO2 symbol will flash continu-
ously as a warning (Fig. 67) until the level of PO2 decreases below 1.60 ATA.
HIGH OXYGEN ACCUMULATION
The O2 bar graph provides you with a convenient graphic representation of
your oxygen accumulation, displaying either oxygen accumulated during that
dive, or during your repetitive dives conducted during that 24 hour period,
whichever of the two is greater at that time.
The yellow Caution Zone of the O2 Bar Graph offers you a convenient way to
consistently monitor how close you are coming to the limits of oxygen toler-
Fig. 67 - High PO2
(=/> 1.60 ATA)
Fig. 66 - High PO2
(=/> 1.40 ATA)
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
55
Data Plus 2
ance. Use it as a visual reference to place a wider margin of protec-
tion between you and the Limits.
If the theoretical amount of oxygen accumulated equals, or exceeds, the limit
for a single exposure, or exposure for a 24 hour period, Oxygen Dive Time Re-
maining becomes 0:00. The O2 Bar Graph will enter the red danger zone (Fig.
68) and the full bar graph will flash as a warning.
You must immediately focus on making a safe controlled ascent to the surface
to prevent further exposure. As your accumulation (dose) decreases during
your surface interval, the O2 bar graph will gradually recede into the yellow
(caution) zone and green (normal) zone.
UNEXPECTED LOSS OF DISPLAYED INFORMATION
If your Data Plus 2 stops working for any reason, it is important that you have
anticipated this possibility and are prepared for it.
If you dive in situations where your trip would be ruined or your safety would
be jeopardized by losing the use of your Data Plus 2, an analog or digital
backup system or use of standard air (or nitrox) tables is highly recommended.
Fig. 68 - High O2
O
2
FT
FT
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
MAX
56
®
WARNINGS and SAFETY RECOMMENDATIONS
• There are few legitimate excuses for making unplanned Decompression dives, and the conse-
quences of this type of diving can be severe. By making an unplanned Decompression dive
without the necessary preparation and training, you will have placed yourself in an unneces-
sarily dangerous situation. Allow a surface interval of at least 24 hours before reentering
the water in the event a dive requires emergency decompression.
• By entering decompression, you automatically impose a “ceiling” above you which you can-
not immediately ascend beyond, denying you free access to the surface.
• Existing data for making planned decompression dives is extremely limited, and virtually
nonexistent for repetitive decompression diving. Decompression diving greatly increases
your risk of decompression sickness.
• Decompression diving, or diving deeper than 130 feet (39 m), will greatly increase your risk
of decompression sickness.
• Special training, equipment, and support are necessary for diving deeper than the maximum
recommended sport diving depth limit of 130 feet (39 meters). Oceanic does not advocate
diving to depths below 130 feet (39 meters), the basis for which is purely theoretical.
57
Data Plus 2
WARNINGS and SAFETY RECOMMENDATIONS
• Exiting the water with the Tissue Loading Bar Graph in the red decompression zone greatly
increases the risk of decompression sickness, and may result in injury or death.
• The oxygen features of the Data Plus 2 are intended for use only by recreational divers
trained for nitrox diving by an instructor certified by a recognized training agency to teach
diving with nitrox.
• The Data Plus 2 enters Immediate Violation Mode when a situation totally exceeds its capac-
ity to predict an ascent procedure. These dives represent gross excursions into decompres-
sion that are beyond the boundaries and spirit of the Data Plus 2 design. If you are follow-
ing these dive profiles, Oceanic advises you not use a Data Plus 2 dive computer.
• If you exceed certain limits, the Data Plus 2 will not be able to tell you how to get safely
back to the surface. These situations exceed tested limits and can result in loss of some Data
Plus 2 functions for 24 hours after the dive in which a violation occurred.
• The Data Plus 2 is not intended for use by military or commercial divers.
58
®
WARNINGS and SAFETY RECOMMENDATIONS
• Maximum limits for exposure to oxygen should not be exceeded, and the consequences of
CNS (Central Nervous System) oxygen toxicity can be severe, resulting in Gran Mal convul-
sions and drowning.
• Conducting repetitive dives using enriched nitrogen-oxygen mixtures can lead to oxygen
buildup, reducing oxygen tolerance while increasing the risk of pulmonary oxygen toxicity.
• In the event that you exceed the maximum per dive allowable oxygen exposure (dose), it is
recommended that you allow a surface interval of at least 2 hours before reentering the wa-
ter. If you exceed the maximum 24 hour period allowable oxygen exposure (dose), you must
allow a surface interval of at least 24 hours before reentering the water.
• Allowing the O2 Bar Graph to enter the red (Danger) zone greatly increases the risk of CNS
oxygen toxicity, and may result in serious injury or death.
• It should not be considered that the capabilities built into the Data Plus 2 provide any im-
plied approval or consent from Oceanic for individuals to exceed the defined limits of recre-
ational dive profiles, as agreed on by all internationally recognized training agencies.
59
Data Plus 2
CARE
and
MAINTENANCE
refer to page 68 for - WARNINGS and SAFETY RECOMMENDATIONS
60
®
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
CARE AND CLEANING
The Data Plus 2 must be protected from shock, excessive heat, chemical at-
tack, and tampering. The housing, made of an impact resistant resin, is ex-
tremely shock resistant but susceptible to chemical attack and scratches. To
protect the lens against scratches, place a transparent Oceanic Instrument
Lens Protector on it. If it becomes scratched, Oceanic can replace it, although
small scratches will naturally disappear underwater.
AFTER THE DIVE
Soak and rinse the Data Plus 2 in fresh water following each dive, and check
the low pressure sensor guard cap to ensure that it is free of any debris or ob-
structions. If possible, use lukewarm water to dissolve any salt crystals. Salt
deposits can also be dissolved using a slightly acidic vinegar/water bath. After
removal from a fresh water bath, place the Data Plus 2 under gently running
water and towel dry before storing. Transport cool, dry, and protected.
ANNUAL INSPECTIONS AND SERVICE
Your Data Plus 2 should be inspected annually by an Authorized Oceanic
Dealer who will perform a factory prescribed function check and inspection for
damage or wear. To keep the 2 year limited warranty in effect, this inspection
Prevent
Scratches with
an Oceanic
Lens Protector
61
Data Plus 2
must be completed one year after purchase (+/- 30 days). Oceanic recom-
mends that you continue to have this inspection performed every year to en-
sure your Data Plus 2 is working properly. The costs of annual inspections are
not covered under the terms of the 2 year limited warranty.
NOTE: Annual inspections are only performed by Authorized
Oceanic Dealers and are not performed by the factory.
TO OBTAIN SERVICE
Take your Data Plus 2 to an Authorized Oceanic Dealer.
To return your Data Plus 2 to Oceanic:
• Obtain an RMA (Return Merchandise Authorization) number by contact-
ing Oceanic at 510/562-0500 or email service@oceanicusa.com.
• Remove accessories and other items not related to service.
• Package it using a protective cushioning material.
• Include a legible note stating specific reason for return, your name, street
address, daytime phone number, serial number, and a copy of your origi-
nal sales receipt and Warranty Registration Card.
• Send insured and freight prepaid using a trackable method to the nearest
Oceanic service facility listed at the right.
• Non-warranty service must be prepaid. COD is not accepted.
OCEANIC USA
2002 Davis Street
San Leandro, Ca. 94577
Tel: 510-562-0500; Fax: 510-569-5404
Oceanic International (Pacific)
Kapolei, Hawaii
Tel: 808-682-5488; Fax: 808-682-1068
Oceanic Europe
Pomezia, Italy
Tel: 39-6-910-4148; Fax: 39-6-910-4163
Oceanic SW, Ltd
Devon, United Kingdom
Tel: 44-1-404-89-1819; Fax: 44-1-404-89-1909
Oceanic Diving Australia Pty. Ltd
Sorrento, Victoria, Australia
Tel: 61-3-5984-4770; Fax: 61-3-5984-4307
Oceanic Asia-Pacific Pte. Ltd
Singapore
Tel: 65-779-3853; Fax: 65-779-3945
Oceanic Germany
Numberg, Germany
Tel: 49-911-324-6630; Fax: 49-911-312-999
Oceanic Japan
Tokyo, Japan
Tel: 3-3664-6541; Fax: 3-3667-6187/6
62
®
Additional information is available at the Oceanic web site -
http://www.oceanicusa.com
NOTE: Be sure to record all dives in the Log. Dive log data will
be erased whenever your Data Plus 2 receives factory service.
BATTERY LIFE
Battery consumption rate varies throughout periods of operation, which begin
upon activation and continue for 24 hours after surfacing from a dive. The ex-
act number of dives, or hours of operation, that you will obtain is subject to
variables, such as, temperature, the number of dives conducted during each
operational period, and the frequency and duration that the backlight is used
(excessive use will reduce battery life).
Tests and calculations indicate that a new Tadiran
®
1/2AA model TL-2150,
.95Ah, 1.0 ma, Lithium battery will maintain unit operation for approximately
350 dive hours (if 1 - 1 hour dive per dive day) to over 700 dive hours (if 2 or
more 1 hour dives per dive day). Yearly replacement is recommended.
NOTE: The disposable battery supplied with the unit is not
covered by the Data Plus 2 limited 2 year warranty.
R
E
S
P
O
N
S
I
B
L
E
D
I
V
E
R
63
Data Plus 2
LOW BATTERY CONDITION
During unit operation, voltage level is checked every 10 minutes. A Low Bat-
tery condition is indicated by the Battery icon appearing on the display (Fig.
69a). Upon decreasing to a voltage level that will not maintain proper unit op-
eration, the icon will flash for 5 seconds followed by shutdown of the unit.
If the unit did not display the Low Battery icon 'prior' to entering the Dive
mode, and a low battery condition occurs during a dive, you will be alerted by
the Low Battery icon appearing on the display. There will be sufficient battery
power to maintain unit operation 'for the remainder of that dive', however the
backlight will be disabled.
BATTERY REPLACEMENT
NOTE: The following procedure must be closely adhered to.
Damage due to improper battery replacement is not covered by
the Data Plus 2 limited 2 year warranty.
MODULE REMOVAL FROM BOOT
Wrist or Hose Mount Boot - peel the lips of the boot downward off the module
while applying pressure from underneath, working it out slowly.
Fig. 69 - Low Battery
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
a
64
®
Console - bend the rubber console boot back to expose the edge of the module.
If the boot is flexible enough to permit, you may bend it back far enough to
scoop the module out with your index finger. Otherwise, it may be necessary
to insert a blunt screwdriver until the tip rests just underneath the module.
DO NOT pry the module from the console! Slowly increase the pressure under
the module by releasing the tension on the rubber boot. The module will slide
up the screwdriver and exit the console.
BATTERY REMOVAL
The battery compartment should only be opened in a dry and clean environ-
ment, with extreme care taken to prevent the entrance of moisture or dust.
Examine the case back to find the Battery Hatch (Fig. 70a):
• Remove the three screws that secure the battery hatch to the housing by
turning counter clockwise with a small philips head screwdriver.
• Lift the hatch up and out of the housing.
• Lift the battery, positive (+) end first, out of the battery compartment.
• Remove the battery hatch o-ring and inspect it for any signs of deteriora-
tion or deformity. DO NOT use tools to remove the o-ring.
• O-ring replacement is highly recommended to ensure proper sealing.
• Check the battery hatch and housing sealing surfaces for any signs of
damage which might impair proper sealing, and the inside of the battery
compartment for any signs of corrosion indicating entrance of moisture.
Fig. 70 - Case Back
a
65
Data Plus 2
• If damage is found, return your Data Plus 2 to your Authorized
Oceanic Dealer, and DO NOT attempt to use it until it has re-
ceived factory service.
If moisture or corrosion is found in the battery compartment, DO NOT use it
until it has received proper service. It is best to have your unit inspected and
cleaned by an Authorized Oceanic Dealer. If you are cleaning it in the field,
proceed as follows:
• Inspect the lens and housing to ensure they are not cracked or damaged.
• Inspect the button coverings to ensure they do not have cuts or holes.
• Remove the battery and discard, DO NOT attempt to reuse.
• Check the battery hatch o-ring for damage (nicks, cuts, divots, etc.). If
found, discard and replace with new.
• Before replacing the o-ring and battery, flush the battery hatch and com-
partment with a solution of 50% white vinegar and 50% water. Rinse
with fresh water, and allow to dry overnight, or blow dry with a hair
dryer (set at 'no heat').
Responsible
66
®
BATTERY INSTALLATION
• To replace the battery hatch o-ring, lightly lubricate it with silicon grease
and place it on the beveled outer edge of the battery compartment (Fig.
71a). Ensure that it is evenly seated.
NOTE: This o-ring must be a genuine Oceanic part that can be
purchased from your Authorized Oceanic Dealer. Use of any
other o-ring will void the Data Plus 2 warranty.
• Place a new 3.6 volt TADIRAN
®
, model TL-2150, .95Ah, 1.0ma, Lithium
battery, negative end first, into the battery compartment toward the
spring, ensuring proper orientation of the positive (+) and negative (-)
ends (Fig. 72).
• Carefully place the battery hatch into position so that it seats on top of
the o-ring, and while holding it in place with your thumb, secure it with
the three screws by turning them clockwise with a small Philips head
screwdriver. DO NOT attempt to use any other screws.
• Carefully tighten the screws until secure by alternately turning them each
one turn at a time. Turn the upper left, then the right, then the lower left..
• Repeat the sequence until all of the screws are evenly secure. The outer
surface of the battery hatch should be flush with the outer surface of the
housing. DO NOT overtighten.
Battery
+
_
+
_
Fig. 71 - O-ring Installation
Fig. 72 - Battery Orientation
a
67
Data Plus 2
INSPECTION
• Activate the unit and watch carefully as it performs a full diagnostic and
battery check and enters Surface Mode.
• Observe the LCD display to ensure it is consistently clear and sharp in
contrast throughout the screen.
• If any portions of the display are missing or appear dim, or if a Low Bat-
tery condition is indicated, return the unit to your Authorized Oceanic
Dealer for a complete inspection before attempting to use it.
RETURNING THE MODULE TO BOOT
• If the boot was fitted with a spacer and it was previously removed, re-
place the spacer into the boot.
• Orient the module over the opening in the boot, and dip the bottom edge
into it while pressing the top edge with the palm of your hand. Stop
pressing when the bottom edge of the module has just entered the boot.
• Correct the alignment of the module as needed so that it is straight.
• Press the module completely into place with your thumbs, watching the
alignment, until it snaps into place.
Care and maintenance is simple and easy, and will help keep your
Data Plus 2 in top condition for years of diving enjoyment.
R
E
S
P
O
N
S
I
B
L
E
D
I
V
E
R
68
®
WARNINGS and SAFETY RECOMMENDATIONS
• When the Low Battery icon is displayed prior to a dive, DO NOT attempt to dive with the
Data Plus 2 until the batteries are replaced.
• Never, under any circumstances, poke any object through any slots or holes of the Data Plus
2. Doing so may damage the depth sensor, possibly resulting in erroneous depth and/or dive
time remaining displays.
• If you are in doubt about the accuracy of your Data Plus 2 depth readings, DO NOT attempt
to dive with it until it has been inspected by Oceanic Customer Service.
• Never pressure test the Data Plus 2 in an air environment. Doing so may damage the depth
sensor; possibly resulting in erroneous depth or time readings.
• Never spray aerosols of any kind on, or near, the Data Plus 2. The propellants may chemi-
cally attack the plastic.
• Nitrogen and Oxygen calculations will be erased when the battery is replaced between re-
petitive dives. Also, date and time settings will have to be reset. To avoid any inconve-
nience, the batteries should be replaced with new prior to any multi-day dive trip that will
include a profile of repetitive dives, such as multiple days on a liveaboard vessel.
69
Data Plus 2
REFERENCE
refer to page 70 for - WARNINGS and SAFETY RECOMMENDATIONS
70
®
WARNINGS and SAFETY RECOMMENDATIONS
• Diving at high altitude requires special knowledge of the variations imposed upon divers,
their activities, and their equipment by the decrease in atmospheric pressures. Oceanic rec-
ommends completion of a specialized Altitude training course by a recognized training
agency prior to diving in high altitude lakes or rivers.
• Altitude compensation provided by the Data Plus 2 takes place when the unit is activated.
DO NOT dive at any different altitude until the Data Plus 2 shuts off. It will recalibrate au-
tomatically when reactivated at the new altitude.
• When returning to lower altitudes, diving should not be conducted until the Data Plus 2 au-
tomatically clears of any residual nitrogen and oxygen loading and resets to operate at the
new altitude.
• Decompression diving is inherently hazardous and greatly increases your risk of decompres-
sion sickness - even when performed according to the computer's calculations.
• Using the Data Plus 2, just as using the U.S. Navy, or other, No Decompression Tables, is no
guarantee of avoiding decompression sickness, i.e. “the bends.”
71
Data Plus 2
NO DECOMPRESSION LIMITS
Note how the No Decompression Limits for the Data Plus 2 are
contrasted with the U.S. Navy limits (Fig. 73). For most depths,
the Data Plus 2 provides somewhat less no decompression times
than the U.S. Navy Tables. However, while the No Decompression
Limits may be less, you will receive greatly increased allowable bot-
tom times as you take advantage of the multilevel dive capabilities
offered by the Data Plus 2. Notice also that the Data Plus 2 Pre
Dive Planning Sequence does not scroll past 160 feet (48 meters).
DECOMPRESSION MODEL
The decompression model used by the Data Plus 2 is based on the
no decompression multilevel repetitive dive schedules successfully
tested by Dr. Ray Rogers and Dr. Michael Powell. These tests did
not include repetitive dives deeper than 90 feet (27 meters) or de-
compression dives.
Due to the present unavailability of statistical data, Data Plus 2 de-
compression predictions are based on U.S. Navy theory. Therefore,
pay special attention to the Warnings and Safety Recommenda-
tions that have been provided in this owner's guide.
Data Plus 2 U.S.
Depth NDL-mins. Navy
feet (meters) Eng (Metric) NDL -mins.
30 (9) 260 (283) - - -
35 - - - - - - 310
40 (12) 137 (144) 200
50 (15) 80 (84) 100
60 (18) 57 (58) 60
70 (21) 40 (41) 50
80 (24) 30 (31) 40
90 (27) 24 (26) 30
100 (30) 19 (20) 25
110 (33) 16 (16) 20
120 (36) 13 (13) 15
130 (39) 10 (11) 10
140 (42) 9 (9) 10
150 (45) 8 (8) 5
160 (48) 7 (7) 5
170 (51) * * 5
180 (54) * * 5
190 (57) * * 5
[* The Data Plus 2 will not scroll past 160 feet
(48 meters), or when projected bottom /descent
time is less than three minutes.]
Fig. 73 - No Decompression Limits
72
®
OXYGEN EXPOSURE LIMITS
Predicted exposure limits and oxygen calculations of the Data Plus 2 are based
on maximum exposure durations (Fig. 74) published by the National Oceanic
and Atmospheric Administration in the October 1991 NOAA Diving Manual.
MULTIPLE TISSUE TRACKING
The Data Plus 2 tracks twelve tissue compartments with halftimes ranging
from 5 to 480 minutes. The Tissue Loading Bar Graph always displays the
controlling compartment that is the only one important at that time. Think of
the Tissue Loading Bar Graph as twelve separate transparent displays laid on
top of one another (Fig. 75). The tissue compartment that has filled up fastest
is the only one the viewer can see from the top.
At any particular point, one tissue compartment may be absorbing nitrogen,
while another that was previously higher may be off-gassing. Figure 76 illus-
trates the point at which one compartment “hands over” control to another
compartment at a different depth. This feature of the Decompression Model is
the basis of multilevel diving, one of the most important contributions the
Data Plus 2 offers you.
Fig. 74 - Oxygen
Exposure Limits
Maximum
Exposure Time
PO2
(ATA)
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
1.50
1.60
Per Dive
(Min)
720
570
450
360
300
240
210
180
150
120
45
Per 24hr
(Min)
720
570
450
360
300
270
240
210
180
180
150
73
Data Plus 2
Fig. 75 - Tissue Compartment Control Fig. 76 - Tissue Compartment Control Hand-Over
11
20
10
40
9
80
8
120
7
160
etc.
etc.
No. of
Segments
Tissue
Half-Time
Display Seen
by the Diver
9
v
9^
40 20
No. of
Segments
Tissue
Half-Time
Display Seen
by the Diver
9
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
6
74
®
SPECIFICATIONS
NO DECOMPRESSION MODEL
Basis:
Modified Haldanean Algorithm
12 tissue compartments
Data Base:
Diving Science and Technology (DSAT) - Rogers/Powell
Performance:
Tissue compartment halftimes (in mins.) Spencer’s “M” values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
Reciprocal subsurface elimination
60 minute surface credit control for compartments faster than 60 minutes
Tissue compartments tracked up to 24 hours after last dive
Decompression Capabilities:
Decompression stop ceilings at 10, 20, 30, 40, 50, & 60 feet
(3, 6, 9, 12, 15, & 18 meters)
Altitude Algorithm:
Based on NOAA tables
Oxygen Exposure Limits:
Based on NOAA tables
OPERATIONAL MODES
Activation/Diagnostic
Surface -
• Temperature/Date/Time
• FO2 Set Point
• Pre Dive Planning Sequence
• Time to Fly/Desaturate
• Dive Log (Date/Nitrogen/Oxygen)
• Set -
• Alternate (On/Off)
• Year, Month, Day
• Hour Format (12/24)
• Hour, Minute
• Sampling Rate
• Units (Imperial/Metric)
• FO2 Default (On/Off)
• External Access (EA)
No Decompression Dive - Main
• Secondary
• Alternate (Large Format)
Decompression Dive -Main
• Secondary
• Alternate (Large Format)
Violation (conditional, delayed, & immediate)
Gauge
High PO2
High O2
• Backlight (Oceanglo
®
/SmartGlo™)
75
Data Plus 2
SPECIFICATIONS (continued)
Variable Ascent Rate Indicator
(VARI):
segments feet/min. meters/min.
0 0 - 20 0 - 6
Normal zone (green) 1 21 - 30 6.5 - 9
Caution zone (yellow) 2 31 - 40 9.5 - 12
3 41 - 50 12.5 - 15
4 51 - 60 15.5 - 18
Too Fast zone (red flashing) 5 61 + 18.5 +
Special Displays:
Occurrence
Diagnostic Display Activation
Out of Range >330 feet (>99.5 meters)
Gauge Mode Countdown Timer 22 - 0 hours (after violation)
OPERATIONAL PERFORMANCE
Function:
Accuracy:
Depth ± 1% of full scale
Timers 1 second per day
Dive Counter:
Displays Dives #1, 2, 3, 4, 5, 6, 7, 8, 9, 0 (continues #1 to #0)
Displays #0 for dives #10, 20, etc.
Resets to Dive #1, upon diving (after midnight - new date)
Dive Log Mode:
Stores 12 most recent dives in memory for viewing
After 12 dives, adds 13th dive in memory and deletes the first dive
DISPLAY RANGE/RESOLUTION
Numeric Displays:
Range: Resolution:
Dive Number 0 - 9 1
Depth 0 - 330 ft (0 - 99.5 m) 1 ft (.5 m)
Maximum Depth 330 ft (99.5 m) 1 ft (.5 m)
FO2 Set Point 21 - 50 % 1 %
PO2 Value .01 - 5.00 ATA .01 ATA
Dive Time Remaining 0 - 9 hr. 59 min. 1 minute
Total Ascent Time 0 - 9 hr. 59 min. 1 minute
Decompression Stop Time 0 - 99 min. (per stop depth) 1 minute
Elapsed Dive Time 0 - 1 hr. 59 min. 1 minute
Surface Time 0 - 23 hr. 59 min. 1 minute
Dive Log Surface Interval 0 - 23 hr. 59 min. 1 minute
Time to Fly 23 hr. 50 min. - 0* 1 minute
(* starting 10 min. after the dive)
Time to Desaturate 9 hr. 59 min. - 0 1 minute
(* starting 10 min. after the dive)
Temperature 0 to 99°F (-9 to 60°C) 1°
GRAPHIC DIVER INTERFACE™
Tissue Loading Bar Graph
:
segments
No Decompression zone (green) 9
No Deco Caution zone (yellow) 2
Decompression Warning zone (red) 1
Oxygen Accumulation (O2) Bar Graph:
segments
Normal zone (green) 9
Caution zone (yellow) 2
Danger zone (red) 1
76
®
SPECIFICATIONS (continued)
Setting FO2:
• Automatically set for 'Air' upon activation
Remains set for Air unless an FO2 numerical value is set
Nitrox set points from 21 to 50 %
If set for 21%, remains set for 21% until changed
If set for >21%, reverts to 50% 10 minutes after the dive (however,
if the FO2 Default setting is OFF, the previous value set will be
retained)
ACCESSORIES
Optional items available from your Authorized Oceanic Dealer:
• Battery Kit - includes 1 battery, 1 o-ring, silicon grease
• Lens Protector - adheres to lens face, prevents scratches
• OceanLog™ for Data Plus 2 - PC Download Package
(hardware and software program)
OPERATIONAL PERFORMANCE (continued)
Altitude:
• Operational from sea level to 14,000 feet (4,267 meters) elevation
• Recalibration of depth readings from 'feet of sea water' to 'feet of fresh water'
when higher than 2,000 feet (610 meters) elevation
Power:
• Battery 1 - 3.6 volt, 1/2AA TADIRAN
®
model TL-2150, .95Ah,
1.0ma, Lithium (must be 3.6 v, .95Ah, 1.0ma rating)
• Shelf life Up to 5 years
• Replacement User replaceable (annual recommended)
• Life expectancy 350 dive hours (if 1 - 1 hour dive per dive day) to over
700 dive hours (if 2 or more 1 hour dives per dive day).
Yearly replacement is recommended.
Activation:
Manual (push button) - cannot be activated by water immersion
Cannot be activated deeper than 4 feet (1.5 m)
Cannot be activated at elevations higher than 14,000 feet (4,267 m)
Needed before first dive.
Automatically shuts off if no dive is made within 120 minutes after initial
activation. Reactivation required.
Cannot be shut off manually.
77
Data Plus 2
GLOSSARY
Air Dive - A dive conducted using air (approximately 21% oxygen & 79% nitrogen) as the breathing gas.
Algorithm - A step-by-step mathematical formula designed to accomplish a particular result (i.e. Dive Time Remaining in the
Data Plus 2).
Altitude Dive - A dive made at an elevation above sea level (2,000+ ft. / 610+ m.) where a different set of no decompression
tables is used .
Ascent Rate - The speed that a diver ascends toward the surface.
C.Z. - Abbreviation for Caution Zone.
Caution Zone - The yellow sections of the Tissue Loading Bar Graph and O2 bar graph that gives a visual warning of a diver’s
proximity to respective decompression or oxygen tolerance limits.
Ceiling - See decompression ceiling.
Clean Dive - A dive preceded by 24 hours of no diving activity.
CNS - Abbreviation for the Central Nervous System of the body.
Competitive Dive - A dive conducted for profit or prize.
Compartment - A term applied to the hypothetical modeling of nitrogen absorption in the tissues (more accurate than the
term “tissue” because dive computer models have no direct relation to human tissues).
DCS - Abbreviation for decompression sickness, i.e., “the bends”.
DECO - Abbreviation for Decompression.
Decompression Ceiling - The shallowest depth a diver may reach upon ascent without risking decompression sickness.
Decompression Stop - The depth(s) at which a diver must pause during ascent to allow absorbed nitrogen to escape naturally
from the tissues.
Depth Sensor - An electro-mechanical device that converts water pressure into an electrical signal, that is converted to a visual
depth display.
Diagnostic Mode - The first display seen on dive computers after initial activation during which time a self–check for internal
faults is performed.
78
®
GLOSSARY (continued)
Display - A visual readout of information.
Dive Log Mode - A computer display of previous dive information.
Dive Time Remaining - A display of the time before a diver must surface based on no-decompression status,or oxygen
accumulation status.
Elapsed Dive Time - The total time spent underwater during a dive between 5 feet (1.5 meters) on initial descent to 3
feet (1 meter) on final ascent.
FO2 - The fraction (percent / 100) of oxygen (O2) in the breathing gas mixture.
Graphic Diver Interface
- A feature of Oceanic dive computers. Easily understandable color coded bar graphs that indicate
diver status; green = normal, yellow = caution, red = danger.
Icon - a small pictorial representation of an operational mode
LCD - Abbreviation for liquid crystal display, an easily viewed low voltage display usually found on dive computers
Maximum Depth - The deepest depth attained during a dive.
Mode - A specific set of functions in a dive computer.
Multiplexing Display - A display on an instrument that alternates to show different information relating to separate events.
Multi-level Dive - A type of dive profile where the diver spends various times at different depths (opposite of a “Square Wave”
dive profile).
Nitrox - A nitrogen-oxygen breathing gas mixture that contains a higher fraction of oxygen than air.
Nitrox Dive - A dive conducted using nitrox (22 to 50 % O2) as the breathing gas.
No Deco - Abbreviation for No Decompression.
No Deco Time Remaining - The amount of dive time remaining based on no-decompression status.
No Decompression - Any part of a dive where the diver can surface without requiring a decompression stop.
O2 Bar Graph - A visual representation of oxygen accumlation on a dive computer display.
Oceanglo
®
- An Oceanic name for an instrument backlight feature.
OceanLog™ - An Oceanic name for a PC interface hardware/software package.
79
Data Plus 2
GLOSSARY (continued)
OTU - Abbreviation for oxygen tolerance unit. A Hamilton's Repex method term for oxygen dose.
Out of Range - The point at which a dive computer can no longer supply correct dive information.
Oxygen Tolerance - Dose or exposure to the physiological affects of elevated levels of oxygen.
Oxygen Toxicity - The adverse physiological affects of exposure to elevated levels of oxygen.
Partial Pressure - The proportion of the total pressure contributed by a single gas in a mixture of gases.
PDPS - Abbreviation for Pre Dive Planning Sequence
PO2 - Partial pressure of oxygen. The proportion of total pressure of a gas mixture contributed by oxygen.
Pre Dive Planning Sequence
- A display of available dive times at 10 foot. (3 meter) intervals from 30 to 160 feet. (9 to 48
meters) used when dive planning.
Repetitive Dive - Any dive that takes place within 12 hours of a previous dive.
Safety Stop - A depth at which a diver may choose, but is not required, to pause during ascent to allow absorbed nitrogen to
escape naturally from the tissues.
Smart Glo™ - An Oceanic name for an instrument backlight feature sensitive to light intensity.
Square Wave Dive - A type of dive profile where the entire dive is spent at one depth between descent and ascent.
Tissue - See Compartment.
Tissue Compartment - See Compartment.
Tissue Loading Bar Graph
- A graphic display of simulated nitrogen absorption on Oceanic dive computers.
TLBG - Abbreviation for Tissue Loading Bar Graph.
Transducer - An electro-mechanical device in a dive computer that acts as a depth or pressure sensor.
Transition Period - The first 10 minutes of surface time after ascending above 3 feet (1 meter) from a dive.
VARI - Abbreviation for Variable Ascent Rate Indicator.
Variable Ascent Rate Indicator
- A display on the Data Plus 2 that shows ascent rate as a bar graph alongside a color–
coded indicator (part of the Graphic Diver Interface).
80
®
DATA PLUS 2 SERVICE RECORD
Serial Number ________________
Date of purchase ______________
Purchased from _______________
Below to be filled in by an Authorized Oceanic Dealer:
R
E
S
P
O
N
S
I
B
L
E
D
I
V
E
R
Date Service Performed Dealer / Technician
THE CODE OF THE
RESPONSIBLE DIVER
AS A RESPONSIBLE DIVER
I UNDERSTAND AND ASSUME
THE RISKS I MAY ENCOUNTER
WHILE DIVING.
RESPONSIBLE DIVING BEGINS WITH
• DIVING WITHIN THE LIMITS OF MY
ABILITY AND TRAINING
• EVALUATING THE CONDITIONS
BEFORE EVERY DIVE AND MAKING
SURE THEY FIT MY PERSONAL
CAPABILITIES
• BEING FAMILIAR WITH AND
CHECKING MY EQUIPMENT BE-
FORE AND DURING EVERY DIVE
• KNOWING MY BUDDY'S ABILITY
LEVEL AS WELL AS MY OWN
• ACCEPTING THE RESPONSIBILITY
FOR MY OWN SAFETY ON EVERY
DIVE
81
Data Plus 2
O
2
M
FT
FT
MAX
M
N
O
D
E
C
O
C
.
Z
.
D
E
C
O
C
.
Z
.
O
2
OCEANIC
Smart
Glo
DataPlus2
®
MAX
g
i
j
f
c
k
e
d
a
b
m
n
l
h
a. Tissue Loading Bar Graph
b. Variable Ascent Rate Indicator
c. Oxygen Loading Bar Graph
d. Icon - Low Battery
e. Icon - Maximum Depth
f. Icon - Log Mode
g. Icon - Temperature
h. Icon - Deco Stop Ceiling
i. Icon - Elapsed Dive Time
j. Icon - Operating Mode (detail A)
k. Symbol - O2 in Control
l. Control Button - Select
m. Control Button - Advance
n. Sensors - Smart Glo™/ Download
Graphic Interface Legend
Surface Plan
No Deco
Deco
O2 Time
O
2
Detail 'A' - Operating Mode Icons
NOTE:
Upper Left
segment does
not exist
Doc. No. 12-2144 (5/99)© 2002 Design 1999
OCEANIC USA
2002 Davis Street
San Leandro, Ca. 94577
USA
Phone: 510/562-0500
Fax: 510/569-5404
Web: http://www.oceanicusa.com
46

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Oceanic Data Plus 2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Oceanic Data Plus 2 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,87 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info