34
TchMode (Touch Pad Mode): This setting is only available for the X-Y touchpad.
Where available, it can be found on the second page of control settings so scroll up to access it. It allows you to set how
the value for the selected axis behaved when you remove your finger from the touchpad as follows:
X1 and X2 axes:
HOLD: Value remains the same
HomeLeft: Value returns to the Low Value
HomeCntr (Home Centre): Value returns to the centre of the control value range
HomeRght (Home Right): Value returns to the High Value
Y1 and Y2 axes:
HOLD: Value remains the same
HomeDown: Value returns to the Low Value
HomeCntr (Home Centre): Value returns to the centre of the control value range
HomeUp: Value returns to the High Value
Name: This setting can be found on the second page of control settings so scroll up to access it. Here you can set the
name for the control that appears on the SL MkII displays. The control name can be a maximum of 8 characters long.
To enter a character first use the encoders or buttons in line with the ‘<’ and ‘>’ symbols on the display to move the cursor
to where you want to enter the character. Then use the buttons in line with ‘Upper’, Lower’ and ‘Punctu’/’Number’ to select
the type of character you want to enter (upper case, lower case, punctuation or number). Note that repeated presses
of the button below ‘Punctu’/’Number’ will switch between ‘Punctu’ and ‘Number’. Finally use the encoder, pot or buttons
in line with ‘CHAR’ to select the character you want to enter. If you want to enter a space then select ‘Punctu’, as the
first punctuation character is a blank space.
non-REGIStERED PARAMEtER nUMBER (nRPn)
The DispType, LowVal, HighVal, Ports, MidiChan, Response, BtnType, TchMode and Name settings are the same as for
Control Change (CC) so see the previous section for information on these settings.
NRPN lsb (Non-Registered Parameter Number Least Significant Byte): This allows you to set the NRPN lsb value for
the control to a value from 0 through 127.
NRPN msb (Non-Registered Parameter Number Most Significant Byte): This allows you to set the NRPN msb value
for the control to a value from 0 through 127.
You can toggle the display format of the NRPN lsb and NRPN msb settings between decimal and hexadecimal by pressing
the row select button for the upper left-hand row of buttons.
REGIStERED PARAMEtER nUMBER (RPn)
The DispType, LowVal, HighVal, Ports, MidiChan, Response, BtnType, TchMode and Name settings are the same as for
Control Change (CC) so see that section for information on these settings.
RPN lsb (Registered Parameter Number Least Significant Byte): This allows you to set the RPN lsb value for the
control to a value from 0 through 127.
RPN msb (Registered Parameter Number Most Significant Byte): This allows you to set the RPN msb value for the
control to a value from 0 through 127.
You can toggle the display format of the RPN lsb and RPN msb settings between decimal and hexadecimal by pressing the
row select button for the upper left-hand row of buttons.