En
Foreword
Thank you for purchasing the Nikon Macro Speedlight SB-29s, an easy-to-use
flash unit offering you the most convenient system for close-up flash
photography in combination with Micro-Nikkor lenses. To get the most out of
your new SB-29s, read this instruction manual thoroughly before use and
keep it handy, so that you can refer to it whenever necessary.
Tips on using the Speedlight
•Before using this unit, read “Tips on Speedlight care” and “For safe handling of the
Speedlight” on the reverse side of this sheet.
•Take some trial shots.
Before taking important flash photographs, take some test shots to ascertain the
SB-29s is working properly.
•Use only Nikon-approved equipment.
The SB-29s is designed for use with Nikon cameras, lenses and accessories. Using
cameras or accessories other than those specified by Nikon may damage the SB-29s.
Nikon cannot be held responsible for malfunctions caused by using the SB-29s in
ways not specified in this manual, or using the SB-29s with a camera made by
another manufacturer.
For details on appropriate Nikon cameras, lenses, and accessories, read each
product’s instruction manual.
Printed in Japan
Set the SB-29s’ power switch to OFF, then slide down the battery chamber
lid in the direction of the arrow and lift it off.
1
•If corrosive liquids seep from the batteries, avoid touching them. Certain
types of batteries contain strong alkaline liquids that can cause chemical
burns. If the alkaline liquids stick to your skin or clothes, wash immediately
with running water.
•When replacing batteries, replace all four at the same time. Do not mix
battery types or brands and do not use old with new batteries. Otherwise, the
batteries may catch on fire or explode, due the possible leakage of corrosive
liquids.
■ Usable lenses
The SB-29s is designed for use especially with Micro-Nikkor lenses to realize
the maximum benefits of the flash unit.
•Use the appropriate adapter ring when attaching the SB-29s to the lens.
Note
Other Nikkor lenses having a ring that rotates or moves forward or backward during
AF operation may not autofocus correctly or may damage the lens or camera’s
autofocus mechanism due to the weight of the main unit. Therefore, do not perform
autofocus operation, but use manual focus instead.
Micro-Nikkor lenses providing maximum benefits
— AF Micro-Nikkor 60mm f/2.8D provides autofocus operation when the Adapter Ring UR-3
(optional) is attached to the lens and the SB-29s main unit is attached to the UR-3.
— AF Micro-Nikkor 105mm f/2.8D or 105mm f/2.8 provides autofocus operation when the SB-29s
main unit is attached to the lens using the provided ø62mm Adapter Ring (not ø52mm).
— AF Micro-Nikkor 200mm f/4D IF or 200mm f/4 IF provides autofocus operation when the
SB-29s main unit is attached to the lens using the provided ø62mm Adapter Ring.
— AF Zoom Micro-Nikkor 70-180mm f/4.5-5.6D ED provides manual focus operation when the
SB-29s main unit is attached to the lens using the provided ø62mm Adapter Ring. Autofocus
operation is not possible.
— Using the PC Micro-Nikkor 85mm f/2.8D set at the Tilt and/or Shift position is not recommended.
Usable lenses with limited functions
•Most Nikkor lenses having a 52mm, 62mm or 72mm filter attachment size
•These lenses are subject to vignetting:
— AF Nikkors 20mm f/2.8D, 28mm f/1.4D, and AF Zoom-Nikkor 24-50mm f/3.3-4.5D (at the
24mm focal length)
— AF Zoom-Nikkor 24-120mm f/3.5-5.6D (at focal lengths of 24mm, 28mm, 35mm and 50mm)
— AF Zoom-Nikkor 28-70mm f/3.5-4.5D (around the 28mm focal length),
— AF Zoom-Nikkor 28-85mm f/3.5-4.5 (at the 28mm focal length)
— AF Zoom-Nikkor 28-100mm f/3.5-5.6G (at the 28mm focal length)
— AF Zoom-Nikkor 28-105mm f/3.5-4.5D (at focal lengths of 28mm and 35mm)
— AF Zoom-Nikkor 28-200mm f/3.5-5.6D (at focal lengths of 28mm, 35mm and 50mm),
AF Zoom-Nikkor 35-70mm f/2.8D (at the 35mm focal length)
•Manual Zoom-Nikkor lenses
Because the adapter ring rotates while focusing, adjust the position of the SB-29s’ main unit
after focusing.
Lenses attachable but virtually unusable
•AF Nikkor lenses having a ring that rotates during AF operation.
Lenses not attachable
•Most Nikkor lenses not having a 52mm, 62mm or 72mm filter attachment size
■ Usable cameras and available flash modes
Nikon cameras usable with the SB-29s for TTL auto and Manual flash operations
Usable lenses and cameras
Usable camera Available flash mode
F5, F100, F4-Series, F90X/N90s*, F90-Series/N90*,
F80-Series/N80-Series*, F70-Series/N70*, F65-Series/N65-Series*,
F60-Series/N60*, F50-Series/N50*, Pronea 600i/6i*, F-801s/N8008s*,
F-801/N8008*, F-601/N6006*, F-601
M
/N6000*, F-401x/N5005*,
F-501/N2020**, F-301/N2000**, F3-Series*
1
, FM3A, FA*
2
, FE2*
2
, FG*
2
,
TTL auto flash*
5
Manual flash
D1-Series*
4
, D100*
4
Manual flash
* Sold exclusively in the USA. ** Sold exclusively in the USA and Canada.
*
1
TTL Flash Unit Coupler AS-17 is required.
*
2
TTL Auto Flash operation is not possible with Nikon FA or FE2 cameras when the shutter
speed is set to M250 or B (bulb), and with Nikon FG cameras when the shutter speed is set to
M90 or B (bulb).
*
3
TTL Auto Flash operation is not possible with the Nikon F-401s/N4004s, F-401/N4004,
New FM2, FM10, FE10 and F55/N55 cameras. Use Manual flash operation instead.
*
4
D-TTL auto flash operation is not possible with the SB-29s.
*
5
3D Multi-Sensor Balanced Fill-Flash is not possible
For your information
The TTL auto flash mode (Multi-Sensor Balanced Fill-Flash, Matrix Balanced Fill-Flash, Center-
Weighted Fill-Flash/Spot Fill-Flash, or Standard TTL flash) is automatically determined, according
to your camera/lens combination. You cannot select an appropriate flash mode on the SB-29s.
For details on available flash modes, read each camera’s instruction manual.
Installing the batteries
Install four penlight batteries following the + and – symbols inside the
battery chamber. Reattach the battery chamber lid by aligning the indices
on the lid and the flash unit and sliding it up as it will go.
2
Caution
Turning the SB-29s on and off/ Standby function
■ Turning the power on and off
Set the SB-29s’ power switch to ON or STBY position.
1
•The standby function is activated if the power switch is set to STBY.
Check that the ready-light comes on.
2
•The SB-29s is ready to fire when the ready-light lights up.
•When the SB-29s is not used, move the power switch to the OFF position to
avoid turning the power on accidentally.
■ Standby function
With the power switch set to STBY position, if both the SB-29s and camera
are not used for after approx. 80 seconds, the SB-29s shuts off automatically
and the ready-light goes out to conserve battery power.
To turn the SB-29s on again after it enters the standby mode:
•With cameras compatible with the TTL auto flash mode, lightly press the camera’s
shutter release button.
•Press the SB-29s’ FLASH button once (in this case, the flash does not fire); or
•Set the power switch to the ON position.
The standby function cannot be used:
•If the SB-29s is mounted on Nikon F3-Series cameras using TTL Flash Unit
Coupler AS-17.
•If the SB-29s is mounted on Nikon New FM2, FM10 or FE10 cameras.
•If the SB-29s is mounted on Nikon FA or FE2 cameras and the shutter speed is set to
M250 or B (bulb).
•If the SB-29s is mounted on Nikon FA or FE2 cameras when Motor Drive MD-12 is
mounted.
•If the SB-29s is mounted on Nikon FG cameras and the shutter speed is set to M90
or B (bulb).
In the above cases, set the SB-29s’ power switch to ON.
Test firing
With the power switch set to ON or STBY, you can perform test firing to
ensure that the SB-29s is working properly.
Check that the ready-light comes on, then press the FLASH button.
•Other Speedlights connected to the TTL multiple flash terminal or sync terminal
will fire as well.
■ Replacing or recharging the batteries (Checking battery power)
Replace or recharge the batteries if the ready-light takes the amount of time
shown in the table to light up between flashes when the flash mode selector is
set at M.
Type of batteries installed Ready-light takes: Remedy
Zinc-carbon
Alkaline-manganese
More than 30 seconds to light up
Replace batteries
Lithium More than 10 seconds to light up
NiCd (rechargeable)
Ni-MH (rechargeable)
Recharge batteries
Attaching the controller and main unit
The SB-29s consists of the controller and main unit. Attach the controller to the
camera and the main unit to the lens or to the front of the controller.
•When attaching the SB-29s to the camera or lens, be sure to turn off the SB-29s.
■ Attaching the controller to the camera
Loosen the SB-29s’ mounting foot lock nut all the way and slide the mounting
foot into the camera’s accessory shoe.
1
Tighten the lock nut by rotating it in the direction of the arrow.
2
■ Detaching the controller from the camera
Loosen the SB-29s’ mounting foot lock nut all the way and gently pull out the
mounting foot.
•If the lock nut doesn’t loosen easily, do not force it. Push the foot forward gently once
in the direction of the white arrow and try loosening the lock nut again.
■ Attaching the main unit to the controller
Press the adapter ring mounting buttons on both sides to attach the main unit
to the controller.
•Keep pressing the adapter ring mounting buttons as you attach the main unit to the
controller, then remove your fingers to secure it.
•The main unit can be rotated up to 90°, allowing horizontal or vertical positioning of
the flash modules.
■Attaching the main unit to the lens
With the lens in normal position
Depending on the lens’ filter attachment size, attach one of the provided
adapter rings to the lens.
1
Press the adapter ring mounting buttons on both sides to attach the main unit
to the adapter ring.
2
•Keep pressing the adapter ring mounting buttons as you attach the main unit to the
adapter ring, then remove your fingers to secure it.
•You can adjust the position of the flash modules by rotating the main unit while lightly
pressing the adapter ring mounting buttons.
With the lens in reverse position
Set the lens in the reverse position when taking pictures at a large
reproduction ratio.
Refer to the illustrations below. These optional accessories are necessary:
•Macro Adapter Ring BR-2A, Auto Adapter Ring BR-6
•Auto Adapter Ring BR-5 is also necessary between Macro Adapter Ring BR-2A and
the lens when using a lens having a 62mm filter attachment size.
•Because Auto Adapter Ring BR-6 features automatic diaphragm control, using the
optional Double Release AR-10 or Double Cable Releases AR-7/AR-4 speeds up
shooting operation.
When attaching the lens directly to the camera body
•Set the lens focus ring to ∞ (infinity) and move the camera body back and forth
to focus.
When using Nikon Bellows Focusing Attachment PB-6
Setting the controller and main unit
Check these settings on the SB-29s before shooting.
Flash mode
Four flash modes—TTL Auto Flash as well as three Manual Flash (M, M1/4, and M1/32)—are
available using the flash mode selector. The TTL Auto Flash mode is recommended,
because determining the proper exposure in close-up flash is very difficult, except when
using Digital SLRs cameras.
Setting both flash modules or either flash module
The SB-29s is equipped with two flash modules. Using the flash module selector, you have
three options: 1) To fire both flash modules simultaneously; 2) To fire the left module only;
or 3) To fire the right module only. This is convenient for taking close-up flash photographs
when you want to emphasize the contrast between the highlight and shadow areas.
Guide number
Guide numbers (at full flash output) in Manual Flash mode (m/ft)
ISO sensitivity 25 50 100 200 400 800 1000 1600
For both flash modules 5.5/18 7.7/25 11/36 15.5/51 22/72 31/102 35/115 44/144
For only one flash module 6/20 8.5/28 12/39 17/56 24/79 34/112 38/125 48/157
NIKON CORPORATION
FUJI BLDG., 2-3, MARUNOUCHI 3-CHOME, CHIYODA-KU, TOKYO 100-8331, JAPAN
01 AF assist illuminator lamp button
02 Modeling illuminator button
03 TTL multiple flash terminal
(Remove the terminal cover from the
terminal and turn it counterclockwise by
90˚ when using the TTL multiple flash
terminal.)
04 Sync flash terminal
05 Light reducer
06 Flash modules
07 AF assist illuminator lamp
08 Flash mode indicator LED
09 Flash mode selector
10 Overexposure warning indicator LED
11 Power switch
12 Mounting foot
13 Hot shoe contacts
14 Mount pin
15 Mounting foot lock nut
16 Alignment indices
17 Battery chamber lid
18 Ready-light
19 FLASH button
20 Flash module selector
Firing both flash modules at the same time
or either independently can be selected.
21 Light reducer setting dial
The ratio of the brightness of the right
flash module to the left one (or vice versa)
can be set to 1:4 using the built-in light
reducer.
22 Adapter ring mounting buttons
23 Reproduction ratio scale
(1:5 represents 1/5x.)
24 ISO sensitivity
The film speed for film-based cameras and
the sensitivity for Digital SLRs cameras are
generally referred to as ISO sensitivity.
25 Effective f-number (aperture)
26 Focal length of lens in use
27 Proper exposure range
Major features of the SB-29s
The SB-29s consists of the main unit and controller. Attach the main unit to
the lens or to the front of the controller to take effective close-up flash
photographs. With the SB-29s, you can shoot ultra close-up photographs of
flowers, insects or small objects in the TTL auto flash mode.
The main unit can be attached to the lens
to take close-up flash photographs.
•The main unit can be rotated while pressing the
adapter ring mounting buttons lightly, allowing you to
set the flash modules at any position to match subject
conditions or your creative preferences.
•Close-up flash photography with a lens mounted in the
reverse position is possible. (Optional Adapter Rings
are required.)
The main unit can be attached to the
controller to take close-up flash
photographs.
As shown in the illustration, the main unit can be rotated
up to 90°. The position of the flash modules can be set
vertically or horizontally to match the subject or your
individual preferences.
Manual flash operation in three (full, 1/4
and 1/32) flash output levels is possible.
Close-up flash operation is easy with
Nikon Digital SLRs cameras featuring a
high ISO sensitivity,
because manual flash
operation at M1/32 flash output level is possible. Note
that the SB-29s is not compatible with the D-TTL auto
flash mode.
The brightness of the flash module can be
reduced to approx. 1/4 flash output by
using the built-in light reducer.
•Various illumination patterns where the brightness is
different on the right and left sides of the subject is
possible when the subject is 0.2m (0.7 ft.) or less from
the main unit.
•Be sure to set both flash modules to fire.
Firing both flash modules at the same time
or firing either independently can be
selected.
Four AA-type penlight batteries of any of these types are usable:
(1) Zinc-carbon (1.5V), (2) alkaline-manganese (1.5V), (3) lithium (1.5V),
(4) rechargeable NiCd (1.2V) and (5) Ni-MH (Nickel-Metal Hydride) (1.2V).
For more information on batteries, refer to “Notes on Batteries.”
Nomenclature
•The main unit cannot be attached to the Adapter Ring if the lens is in the reverse
position with the PB-6 attached.
•Set the lens focus ring to ∞ (infinity).
Only right module fires
Both modules fire
Only left module fires