619207
15
Verklein
Vergroot
Pagina terug
1/22
Pagina verder
350-20062
15
PM350-20062R13315 nv Niko sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@niko.be — www.niko.eu EN
17. Press the button with the value closest to the
second reference point (e.g.
).
The blue indication LED goes out, and the red
and blue indication LEDs light up at the same
time. The lux value is set and the lighting in
zone 1 is switched off.
18.
Press
or .
You set the third reference point in zone 2 to
the highest light level possible (e.g. 400 lux).
Note: The light level must be as close as
possible to the fixed values on the IR remote
control.
19. Press the button with the value closest to the
third reference point (e.g.
).
The red and blue indication LEDs go out, and
the green indication LED lights up. The lux
value is set.
20. Press the button with the value closest to the
lux value of your choice (e.g.
for 200 lux).
You set the lux value of your choice for zone
2 at table height.
The green indication LED goes out. The lux
value is set.
21.
Press
once.
The sensor is locked again and returns to the
control mode. The device will now use the new
settings.
5.4. Setting the hallway function
You can use the presence detector in rooms with no available daylight, such as hallways. In this case, the lighting
will be used as orientation lighting, with the light level varying between 100% and one of the preset levels. Use the
example below to correctly enter the settings for the hallway function of the sensor.
Example (see also figure 9): The switch-off delay of your choice, i.e. the time between the last movement and the
moment at which the lighting is dimmed to a lower light level (orientation lighting), must be set to 20 minutes. The
light level of the orientation lighting must be set at 20%. After 21 minutes, the lighting will be switched off.
Step Action Result
1. Set DIP switch 1 to OFF (factory setting). You can now set the device using the IR remote
control.
2.
Press
three times.
The sensor is unlocked and the green indication
LED is flashing once.
3. Turn the LUX potentiometer all the way to the
right (maximum setting).
a. The red indication LED starts flashing.
b. As soon as the potentiometer has reached the
maximum light level, the blue indication LED
will light up. The hallway function is selected
correctly and now activated.
4.
Press
once.
The red indication LED starts flashing to indicate
that the signal has been received properly.
When you press this button, the factory setting
for the switch-off delay (10 min) is increased
by 10 minutes. The switch-off delay is now set
to 20 minutes.
5.
Press
three times.
The red indication LED starts flashing to indicate
that the signal has been received properly.
When you press this button three times,
the factory setting for the light level of the
orientation lighting (5%) is increased by 15%.
The light level is now set at 20%.
6.
Press
twice.
The red indication LED starts flashing to indicate
that the signal has been received properly.
When you press this button, the factory setting
for the switch-off delay of the orientation
lighting (1 min) is increased by 20 minutes. The
switch-off delay of the orientation lighting is
now set to 21 minutes.
7.
Press
once.
The sensor is locked again and returns to the
control mode. The device will now use the new
settings.
6. OPERATION AND USE
6.1. General operation
The integrated light sensor continuously measures the daylight level in the detection area and compares this level to
the preset lux value. Thanks to the light sensor, the light switches on automatically only if the detector detects motion
within the detection range and if the daylight level falls below the preset lux value:
The lighting remains switched on as long as motion is detected.
After the last motion is detected, the lighting remains switched on for the duration of the
preset switch-off delay (1 to 60 minutes). As soon as the switch-off delay has elapsed, the lighting
switches to orientation lighting. As soon as the switch-off delay of the orientation lighting has elapsed,
the lighting switches off.
As the daylight level increases, the lighting in the room is dimmed until the preset minimum
level is reached.
The lighting switches off automatically as soon as the daylight level is sufficiently high.
6.2. Applications
There are two applications possible on this presence detector:
manual application: manual on/off via push button, automatic off via presence detector, or dependent
on the light level.
automatic application (can only be selected with the IR remote control): automatic on/off via
presence detector, dependent on the light level.
Mode Application Mode of operation
Ceiling lighting manual Switching of DALI and DSI daylight control
1
in two zones via a push
button.
If necessary, you can switch on the lighting according to the preset
parameters.
As long as the device detects presence, the lighting is adjusted
according to the preset parameters.
automatic Automatic switching of DALI and DSI daylight control
1
in two zones
via a presence detector.
manual and
automatic
Press the push button briefly to switch the lighting off. After
approximately ten seconds the presence detector is once again ready to
switch the lighting on automatically.
Dimming lights manual and
automatic
Press and hold the push button to dim or brighten the lighting.
You can also dim/brighten the lighting using the IR remote control.
When the dim function is activated, you must switch off the
lighting so that it can once again be switched on and can function
according to the daylight measurements (via the integrated light
sensor).
1
The two zones are connected to their own DALI or DSI bus in zones 1 and 2.
You can also carry out these applications with the IR remote control as described in section 4.1.
7. TROUBLESHOOTING
Problem Cause Solution
The calibration was not
successful: the red indication LED
keeps flashing.
- Insufficient daylight (or not
enough daylight is registered by
the sensor).
- Too much daylight, which
means the sensor is saturated.
- There are not enough variations
in the artificial light level (or the
variations are not adequately
registered by the sensor).
- The daylight level was varying
too much during calibration.
- Press
and repeat the
calibration.
- Press
once. The sensor
is locked and returns to the
factory settings.
An error occurred while setting
the first reference point in zone 1:
the red indication LED is flashing
briefly and then stays lit.
- Insufficient daylight (or not
enough daylight is registered by
the sensor).
- The daylight level was varying
too much while setting.
- Press
or
to reset the
reference point.
- Press
once. The sensor
is locked and returns to the
factory settings.
An error occurred while setting
the second reference point in
zone 1: the red indication LED is
flashing briefly and the red and
blue indication LEDs then stay lit.
- Insufficient daylight (or not
enough daylight is registered by
the sensor).
- The two reference points are
identical.
- The difference between the
artificial light level in both
reference points is too small.
- The daylight level was varying
too much while setting.
- Press
or
to reset the
reference point.
- Press
once. The sensor
is locked and returns to the
factory settings.
An error occurred while setting
the first reference point in zone 2:
the red indication LED is flashing
briefly and then stays lit.
- Insufficient daylight (or not
enough daylight is registered by
the sensor).
- The daylight level was varying
too much while setting.
- Press
or
to reset the
reference point.
- Press
once. The sensor
is locked and returns to the
factory settings.
An error occurred while setting
the second reference point in
zone 2: the red indication LED is
flashing briefly and the red and
blue indication LEDs then stay lit.
- Insufficient daylight (or not
enough daylight is registered by
the sensor).
- The two reference points are
identical.
- The difference between the
artificial light level in both
reference points is too small.
- The daylight level was varying
too much while setting.
- Press
or
to reset the
reference point.
- Press
once. The sensor
is locked and returns to the
factory settings.
8. MAINTENANCE
Dirt may prevent the presence detector from functioning properly. Therefore, always keep the lens clean and
dry. Use a damp cloth and water with some detergent to clean the lens. Never exert pressure to wipe the lens
clean. If the lens or other parts of the presence detector are defective, please contact an authorised installer.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Niko 350-20062 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Niko 350-20062 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 19,58 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info