571164
9
Verklein
Vergroot
Pagina terug
1/24
Pagina verder
Thermic Distribution Europe / 5 Rue du Lion - 5660 Couvin - Belgium
IQ33#6700A
WOODBOX® TECHNOLOGY
Instructions
Instructions
Thermic Distribution Europe s.a.
5, rue du Lion
5660 Couvin
Belgique
2
3
• Have a quali ed professional install your appliance.
• In the event of a problem, contact him directly.
Ask him to obtain the original NESTOR MARTIN parts. Beware of forgeries. To obtain a part, contact your installer/
dealer in order to identify the order number of the part. Pass on this information to your installer and he will order the
part directly from NESTOR MARTIN.
• It is recommended not to overestimate the power of the appliance in relation to the space to be heated.
• When used with air under a fully open grate, this appliance must be supervised.
Safety requirements
Please read carefully all the instructions before installing or using this product. Any errors made in the installation,
adjustment, use or maintenance of this product can cause personal injury or damage to property.
The appliance must be placed away from furniture and curtains. Warn adults and especially children of the dangers of
high temperatures and burns
Supervise children when they are in the same room as the appliance. The appliance must be thoroughly inspected
and the chimney must be swept at least once a year. However, in the event of improper installation, malfunction or
poor quality fuels, the chimney must swept more often.
DO NOT OVERHEAT THE APPLIANCE.
IF A PART OF THE APPLIANCE OR THE FLUE BECOMES RED, THE APPLIANCE IS OVERHEATING.
Supply combustion air to the house when using the appliance. A partially open window or an outside air vent near
the appliance is acceptable or install the exterior air inlet system included with the appliance. Do not connect the
appliance to an air distribution system or duct.
IQH 13 IQ 33 IQ 43 IQH 33 IQH 43
Nominal output [kW] 6.5 9 10.5 9 12
Мaximal output [kW] 8 12 14 14 16
Mass of the appliance [kg] 146 135 182 178 197
Minimum draft [Pa] 12 12 12 12 12
Flue gas mass flow [g/s] 7.5 - - 6.2 12.4
minimum isolation thickness [mm] (*) back 27 84 84 84 84
minimum isolation thickness [mm] (*) sides 65 65 65 65 51
smoke temperature [°C] 265 264 398 356 390
In relation to the combustible elements, measured on the basis of silical 1000
4
DIMENSIONS INSTALLATION
L
hH2
H1
I
a
b
P
d
D
IQ33 IQ43 IQH13 IQH33 IQH43
L [mm] 584 692 442 584 692
H1 [mm] 695 717 908 961 897
H2 [mm] 643 668 868 909 845
h [mm] 644 666 871 912 848
I [mm] 583 691 442 583 691
P [mm] 450 498 444 450 498
b [mm] 371 421 379 371 421
a [mm] 249 280 232 249 280
D [mm] 150 180 150 180 180
d [mm] 120 120 100 120 120
LC
HC
25255050
dimensions with frames
5
LC HC LC HC LC HC LC HC LC HC
frame 3 sides width 25 mm 618 661 726 683 476 886 618 927 726 863
frame 4 sides width 25 mm 618 678 726 700 476 903 618 944 726 880
frame 3 sides width 50mm 668 686 776 708 526 911 668 952 776 888
frame 4 sides width 50mm 668 728 776 750 526 953 668 994 776 930
IQ43 IQH13 IQH33 IQH43
type of frame IQ33
• Installation must conform to current building regulations.
• The position of the appliance must respect the minimal distances in regards to combustible materials, shown on the
descriptive plate. If necessary, install a wall protector. If the ground is not tiled, (i.e. tted carpet, parquet…) install a
oor protector plate which extends out from under the appliance for at least 20cm at the back, 20cm at the sides and
50cm at the front.
• Make sure that the chimney is clean, free of soot or debris, and as straight as possible.
• The chimney ue must be airtight and the inner walls as smooth as possible.
• The connection between the chimney and the appliance must be as equally airtight and made of non-combustible
materials, protected, if possible, against oxidation (enamelled sheet metal, aluminium, stainless steel…).
The chimney must be high enough and constructed to avoid backdraft. It should be protected with insulating materials
to lower the risk of sooting in the high part of the chimney ue, and if necessary, it should be covered to avoid rain water
from penetrating.
The chimney must be designed and built in a way to allow a suf cient draw so as to completely clear the smoke from
the inside. As a rule:
1. The chimney must be at least 90cm higher that the point on the roof from which it emerges.
2. and be at least 60cms higher than any part of the building within a radius of 3m.
For the best draw, the chimney should be at least 5m long from the ue outlet of the appliance.LA
INSTALLATION INSTRUCTIONS
HEIGHT OF THE CHIMNEY
300 cm
60 cm
90 cm
6
7
HOT AIR DISTRIBUTION
Your appliance is equipped with a heat recovery system and two ue outlets which allow
exible tubes to be connected. The exible tubes can be arranged in such a way that the
hot air is blown into other rooms.
If you prefer the hot air to come from the ducts and from the front at the same time, it is
possible to remove the de ectors. To access the de ectors you must rst remove the lters.
Case 1 – hot air comes only from the front: leave the two de ectors and the lters in place.
Case 2 – hot air comes from the tubes and from the front at the same time.
Remove the cover (6 screws).
Remove the two steel de ectors
Replace the stop gap with the steel ue outlets
Observe that for IQ33, IQH33, IQ43 and ’IQH43 it is possible to remove the
de ectors through the lter without removing the cover.
ue outlet
ector
Cover
stop gap
ATTACHING THE FRAMES (OPTIONAL)
8
Remove the original frame’s xing screws (9 screws)
Remove the two stoppers (2 screws) and remove the two screws present under the stoppers.
Move the original frame back by 6mm
Attach the optional frame (4 screws)
To attach one of the optional frames, proceed as follows:
xing screw of
original frame
xing screw of
original frame
xing screw of optional
frame
original frame
optional frame
left stopper left stopper
Respect the minimal tting measurements
POSITIONING THE INSET
type 1 con guration, with over owing frame
type 2 con guration, with tted frame
D = height of inset
F = width of inset
M = depth of inset
N + 20mm = Maximum dimension between the chimney posts.
E + 20mm = Maximum dimension between the base of the inset and the upper beam.
If your chimney has a wooden beam, it is
necessary to isolate the lower part of it if it is
closer that 30cm to the hot air outlet.
9
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Nestor Martin IQH33 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Nestor Martin IQH33 in de taal/talen: Engels als bijlage per email.

De handleiding is 1.05 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Nestor Martin IQH33

Nestor Martin IQH33 Gebruiksaanwijzing - Nederlands - 25 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info