812864
1
Verklein
Vergroot
Pagina terug
1/18
Pagina verder
a Quick start guide
Blood Pressure Monitor HCBL400WT
For more information see the extended manual online: ned.is/hcbl400wt
Intended use
This product is intended to measure the diastolic and systolic blood pressure and pulse rate
of an adult.
The product is not intended for use on neonates, children or pregnant women.
This product is not intended for medical use.
The product is intended for indoor use only.
Any modication of the product may have consequences for safety, warranty and proper
functioning.
Specications
Product Blood Pressure Monitor
Article number HCBL400WT
Dimensions (l x w x h) 136 x 120 x 61 mm
Weight (excl. batteries and cu) 225g
Cu circumference 22 - 42 cm
Measuring method Oscillometric method, automatic ination and measurement
Measurement range
Cu pressure 0 - 300 mmHg
Systolic 60 - 260 mmHg
Diastolic 40 - 199 mmHg
Pulse rate 40 - 180 beats/minute
Accuracy
Pressure ± 3 mmHg
Pulse rate Less than 60: ±3bpm
More than 60 (incl.) : ±5%
Precision 1 mmHg
Memory 2 x 60 measurements
Battery type 4 x 1.5 V AA batteries (not included)
Battery life Approximately 270 times
Operating temperature 10 - 40 °C
Storage temperature -20 - 50 °C
Relative humidity ≤85 %
Environmental pressure 80 - 105 kPa
Main parts (image A)
1 Storage bag
2 Cu
3 Rubber air tube
4 Air tube connector
5 Battery compartment
6 Memory button
7 Start button
8 Irregular heartbeat indicator
9 Low battery indicator
q Pressure in the cu is instable or there is a lot of
remnant air in the cu
w Blood pressure level classication indicator
e Time and date display
r Systolic blood pressure
t Diastolic blood pressure
y Pulse rate
Safety instructions
-
WARNING
Ensure you have fully read and understood the instructions in this document before you
install or use the product. Keep the packaging and this document for future reference.
Only use the product as described in this document.
Do not use the product if a part is damaged or defective. Replace a damaged or defective
product immediately.
Do not drop the product and avoid bumping.
Do not expose the product to water or moisture.
Only use the provided power cable.
Disconnect the product from the power source and other equipment if problems occur.
Do not unplug the product by pulling on the cable. Always grasp the plug and pull.
This product may only be serviced by a qualied technician for maintenance to reduce the
risk of electric shock.
Consult with a doctor before use if you have any medical concerns.
Do not use this product in a moving vehicle. This may result in inaccurate measurements.
Inserting the batteries (image B)
1. Open the battery compartment A5.
2. Place the batteries.
3. Close A5.
Setting the time and date
1. Press and hold the start button A7 and the memory button A6 simultaneously for two
seconds.
The time format starts to blink. The product is now in time format adjustment mode.
4If no button is pressed for 60 seconds, the product exits time and date adjustment mode.
2. Press A6 to change the time format.
3. Press A7 to conrm.
The product is now in year adjustment mode.
4. Press A6 to adjust the number.
5. Press A7 to conrm.
The product is now in month adjustment mode.
6. Repeat steps 4 – 5 to set the month, date, hour and minutes.
Connecting the cu
1. Insert the rubber air tube A3 into the air tube connector A4.
4The connector must be completely inserted to prevent air leakage during blood pressure
measurements.
Applying the cu
1. Place the cu A2 around a bare upper arm.
4A2 must be placed 1-2 cm above the elbow joint.
2. Choose an arm to measure on. Always measure on the same arm.
4If A2 is applied on the left arm, A3 must be on the inside of the arm, aligned with the
middle nger.
4If A2 is applied on the right arm, A3 must be at the side of the elbow.
4A2 should be tight but comfortable. It should be possible to insert a nger between the
arm and A2.
Body posture during measurement
Sitting down
1. Sit down.
2. Put your feet at on the oor.
3. Place your hand on a at surface with the palm up.
4Do not rest your arm on A3. This may restrict the airow to A2.
4. Position your arm so A2 is at the same height as your heart.
5. Sit calmly for 5 minutes before starting the blood pressure measurement.
Lying down
1. Lie on your back.
2. Place your arm straight along your side with the palm up.
3. Position your arm so A2 is at the same height as your heart.
4. Lie calmly for 5 minutes before starting the blood pressure measurement.
Measuring blood pressure
1. Press A7.
4All symbols - A8 to Ay - are shown on the display. If not all symbols are visible, contact
the service center.
The current memory group starts to blink in the place of At.
4Memory groups can be used to store measurements for multiple people on the same
device.
2. Press A6 to switch memory groups.
3. Press A7 to conrm.
4The memory group is also conrmed automatically after 5 seconds of inactivity.
The display shows the most recent measurements.
If no measurements are stored in the memory group, the display shows zeroes.
The product starts to seek zero pressure.
A2 inates until sucient pressure has built up for a measurement.
A2 slowly deates while the measurement is carried out.
The results are shown on the display.
4The measurements are automatically stored.
4. Press A7 to switch o the display manually.
4The display switches o automatically after 1 minute of inactivity.
Reading measurements from the memory
1. Press A6.
The current memory group is shown in the place of At.
2. Press A7 to switch memory groups.
3. Press A6 to conrm.
4The memory group is also conrmed automatically after 5 seconds of inactivity.
The display shows the average values of all measurements in the current memory group.
If no measurements are stored in the memory group, the display shows zeroes.
4. Press A6 to show the average values of the last three measurements in the current
memory group.
5. Press A6 to show the number of stored measurements in the current memory group.
6. Press A6 to show the most recent measurements.
7. Press A6 repeatedly to show the previous measurements.
8. Press A7 to switch o the display manually.
4The display switches o automatically after 1 minute of inactivity.
Deleting measurements from the memory
1. When the display shows a measurement, press and hold A6 for three seconds to delete
all measurements in the current memory bank.
Technical alarm
If the measured blood pressure is outside the rated range, the display shows ‘Hi’ or ‘Lo as
technical alarm.
1. Check if the measurement was performed correctly.
2. If the measurement was performed correctly, consult your physician.
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Nedis HCBL400WT bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Nedis HCBL400WT in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info