A 1NAVMAN W100 User Manual Addendum
W100 SECONDARY FUNCTIONS
Addendum to manual
(Changing Wind Direction Damping)
SECONDARY FUNCTIONS
Press and hold both the
#
and
^
keys for 3 seconds.
Wind direction damping. The damping level is displayed on the lower section of
the LCD (d0, d1, d2 or d3). The V and ^ keys are used to adjust the damping to
the required value. To exit press the
# key. The damping levl is saved in NVM.
Momentarily press both the
#
and
^
keys.
Wind speed calibration. The upper section of the display will show ‘CA’. The lower
section will display wind speed. The V and ^ keys are used to adjust the wind
speed to the required value. To exit press the
# key. The results of the calibration
process are saved in NVM.
Momentarily press both the
#
and
^
keys.
Wind vane alignment procedure. The lower section of the display will show ‘CA’.
The upper section will display wind direction. The V and ^ keys are used to align
the displayed wind direction with the wind vane. To exit press the
# key. The
results of the calibration process are saved in NVM.
Press and hold both the
#
and
^
keys for 6 seconds. During this period the display
will flash. At the end of the 6 second period the display with show ‘LE’.
Linearisation procedure. The lower section of the display will show ‘LE’. The wind
vane must be rotated through two complete revolutions to allow the W100 to
perform the automatic linearisation process. Press the
# key to exit. The results of
the linearisation are saved in NVM.
W100/ADD/1A