Installation and
English
owner's manual
MUCSR-H6
CASSETTE SERIE H6
www.mundoclima.com
Thank you very much for purchasing our products.
Please read this manual carefully before installing
and using the unit.
CL20232 to CL20238
CONTENT
OWNER'S MANUAL .....................................................................................................22
INSTALLATION MANUAL ............................................................................................. 3
32
2
REMOTE CONTROLLER ............................................................................................
Thank you for selectiong super quality Air Conditiones. To ensure satisfactory operation for many ears to come,
this manual should be read carefully before the installation and before using the air conditioner. After reading,
store it a safe place. Please refer to the manual for questions on use or in the event that any irregularities occur.
This Air Conditioner should be used for hosehold use.
This unit must be installed by a professional according RD 795/2010, RD 1027/2007 and RD 238/2013.
The power supply must be SINGLE-PHASE (one phase (L) and one neutral (N)) with his grounded power (GND))
switch. Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer.
In line with the company's policy of continual product improvement, the aesthetic and dimensional characteristics,
technical data and accessories of this appliance may be changed without notice.
IMPORTANT
WARNING
NOTE
Read this manual carefully before installind or operating you new air conditioning unit. Make sure to save this
manual for future reference.
ATTENTION
or THREE-PHASE (three phase (L1, L2, L3) and one neutral (N) with his grounded power (GND)) and his manual
INSTALLATION MANUAL
3
INVERTER SPLIT-TYPE
ROOM AIR CONDITIONER
The design and specifications are subject to
change without prior notice for product improvement.
Read This Manual:
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly.
Just a little preventative care on your part can save you
a great deal of time and money over the life of your air
conditioner.
You'll find manyanswers to common problems in the
chart of troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need to call for
service.
Please read this manual carefully before installing
and using the unit.
PRECAUTIONS
INSTALLATION INFORMATION
ACCESSORIES
INDOOR UNIT INSTALLATION
OUTDOOR UNIT INSTALLATION
INSTALL THE REFRIGERANT PIPE
INSTALL THE DRAIN PIPE
ELECTRIC WIRING WORK
TEST OPERATION
..................................................... ........ .. ...4
............................................................................21
.. . ..............
..........................................................5
...................................................................................6
...........................................................7
.....................................................12
.................................................14
............................................................16
...............................................................18
CONTENTS Page
Keep this manual where the operator can easily find them.
Read this manual attentively before starting up the units.
For safety reason the operator must read the following
cautions carefully.
The safty precautions listed here are divided into two categories.
If you do not follow these instrutions exactly, the unit may
cause property damage, personal injury or loss of life.
If you do not follow these instrutions exactly, the unit may
cause minor or moderate property damage, personal injury.
After completing the installation, make sure that the unit operates
properly during the start-up operation. Please instruct the customer on
how to operate the unit and keep it maintained.Also, inform customers
that they should store this installation manual along with the owner's
manual for future reference.
Be sure only trained and qualified service personnel to install,
repair or service the equipment.
Improper installation, repair, and maintenance may result in
electric shocks, short-circuit, leaks, fire or other damage to the
equipment.
Install according to this installation instructions strictly.
If installation is defective, it will cause water leakage, electrical
shock and fire.
When installing the unit in a small room, take measures
against to keep refrigerant concentration from exceeding
allowable safety limits in the event of refrigerant leakage.
Contact the place of purchase for more information. Excessive
refrigerant in a closed ambient can lead to oxygen deficiency.
Use the attached accessories parts and specified parts for
installation.
otherwise, it will cause the set to fall, water leakage, electrical
shock and fire.
Install at a strong and firm location which is able to withstand
the set' s weight.
If the strength is not enough or installation is not properly done,
the set will drop to cause injury.
The appliance must be installed 2.3m above floor.
The appliance shall not be installed in the laundry.
Before obtaining access to terminals, all supply circuits must
be disconnected.
The appliance must be positioned so that the plug is accessible.
The enclosure of the appliance shall be marked by word, or by
symbols, with the direction of the fluid flow.
For electrical work, follow the local national wiring standard,
regulation and this installation instructions. An independent
circuit and single outlet must be used.
If electrical circuit capacity is not enough or defect in electrical
work, it will cause electrical shock or fire.
Use the specified cable and connect tightly and clamp the
cable so that no external force will be acted on the terminal.
If connection or fixing is not perfect, it will cause heat-up or fire
at the connection.
Wiring routing must be properly arranged so that control board
cover is fixed properly.
If control board cover is not fixed perfectly, it will cause heat-up
at connection point of terminal, fire or electrical shock.
If the supply cord is damaged, it must be replaced by the
manufacture or its service agent or a similarly qualified person
in order to avoid a hazard.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed wiring.
When carrying out piping connection, take care not to let air
substances go into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure
in the refrigeration cycle, explosion and injury.
Do not modify the length of the power supply cord or use of
extension cord, and do not share the single outlet with other
electrical appliances.
Otherwise, it will cause fire or electrical shock.
PRECAUTIONS
WARNING
WARNING
CAUTION
INSTALLATION MANUAL
4
REFRIGERANT PIPE (The unit with the Twins function).................. 21
Indoor unit installation;
Outdoor unit installation;
Install the refrigerant pipe;
Connect the drain pipe ;
Electric wiring work;
T
Test operation.
wins function
If the refrigerant leaks during installation, ventilate the area
immediately.
Toxic gas may be produced if the refrigerant comes into the
place contacting with fire.
The temperature of refrigerant circuit will be high, please keep
the interconnection cable away from the copper tube.
After completing the installation work, check that the refrigerant
does not leak.
Toxic gas may be produced if the refrigerant leaks into the
room and comes into contact with a source of fire, such as a
fan heater, stove or cooker.
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes, lightning
rod or a telephone ground wire.Inappropriate grounding may
result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric
shocks.
Connect the outdoor unit wires , then connect the indoor unit
wires.
You are not allowed to connect the air conditioner with the
power supply until the wiring and piping is done.
While following the instructions in this installation manual, install
drain piping in order to ensure proper drainage and insulate
piping in order to prevent condensation.
Improper drain piping may result in water leakage and property
damage.
Install the indoor and outdoor units, power supply wiring and
connecting wires should be at least 1 meter away from
televisions or radios in order to prevent image interference or
noise.
Depending on the radio waves, a distance of 1 meter may not
be sufficient enough to eliminate the noise.
The appliance is not intended for use by young children or
infirm persons without supervision.
Don't install the air conditioner in the following circumstance:
The appliance shall be installed in accordance with national
wiring regulations.
Do not operate your air conditioner in a wet room such as a
bathroom or laundry room.
An all-pole disconnection device which has at least 3mm
clearances in all poles , and have a leakage current that may
exceed 10mA, the residual current device (RCD) having a rated
residual operating current not exceeding 30mA, and
disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
CAUTION
There is petrolatum existing.
There is salty air surrounding (near the coast).
There is caustic gas (the sulfide, for example) existing
in the air (near a hot spring).
The Volt vibrates violently (in the factories).
In buses or cabinets.
In kitchen where it is full of oil gas.
There is strong electromagnetic wave existing.
There are inflammable materials or gas.
There is acid or alkaline liquid evaporating.
Other special conditions.
To install properly, please read this "installation manual" at
first.
The air conditioner must be installed by qualified persons.
When installing the indoor unit or its tubing, please follow
this manual as strictly as possible.
If the air conditioner is installed on a metal part of the
building, it must be electrically insulated according to the
relevant standards to electrical appliances.
When all the installation work is finished, please turn on
the power only after a thorough check.
Regret for no further announcement if there is any change
of this manual caused by product improvement.
INSTALLATION INFORMATION
INSTALLATION ORDER
INSTALLATION MANUAL
5
ACCESSORIES
Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully.
Tubing & Fittings
NAME SHAPE QUANTITY
1
1
1
1
1
1
2
1
1
2
2
1
(on some models)
1
(on some models)
1. Soundproof / insulation sheath
2. Binding tape
3.Seal sponge
4. Drain joint
5. Seal ring
6. Remote controller RG57
7. Frame
8. Mounting screw(ST2.9 0-C-H)
9.Alkaline dry batteries (Am4)
10. Magnetic ring
(twist the electirc wires L and N
around the magnetic ring to five
circles)
11.installation and Owner's manual
12. Connecting wire for display (2M)
13. Cord protection rubber ring
Drainpipe Fittings
(for cooling & heating)
Remote controller & Its Frame
EMC & Its Fitting
(for some models)
Others
INSTALLATION MANUAL
6
INSTALLATION MANUAL
Ceiling height
Use installation hooks for installation.Check whether the
ceiling is strong enough to support the weight of the indoor
unit.If there is a risk,reinforce the ceiling before installing
the unit.
Space required for installation see the figure below ( :air flow
direction)
Install this unit where the height of bottom panel is more than
2.5m so that the user cannot easily touch.
2)
3)
Do not install the unit in an area where flammable materials
are present due to risk of explosion resulting in serious
injury or death.
DANGER
If the basis underneath the unit is not strong enough to
support the weight of the unit, the unit could be fall out of
place and cause serious injury.
WARNING
Select an installation site where the following conditions are
fulfilled and that meets your customer's approval.
- Where optimum air distribution can be ensured.
- Where nothing blocks air passage.
- Where condensate water can be properly drained.
- Where the false ceiling is not noticeably on an incline.
- Where sufficient clearance for maintenance and service can be
ensured.
- Where there is no risk of flammable gas leaking.
- The equipment is not intended for use in a potentially explosive
atmosphere.
- Where piping between indoor and outdoor units is possible
within the allowable limit.(Refer to the installation manual of the
outdoor unit.)
- Keep indoor unit,outdoor unit,inter unit wiring and remote
controller wiring at least 1 meter away from televisions and
radios.This is to prevent image interference and noise in those
electrical appliances.(Noise may be generated depending on
the conditions under which the electric wave is generated,even
if 1 meter is kept.)
- When installing the wireless remote controller kit,the distance
between wireless remote controller and indoor unit might be
shorter if there are fluorescent lights who are electrically started
in the room.The indoor unit must be installed as far as possible
away from fluorescent lights.
1.1 Selecting installation site
0
When the conditions in the ceiling are exceeding 30 C and a relative
humidity of 80%, or when fresh air is inducted into the ceiling, an
additional insulation is required (minimum 10 mm thickness,
polyethylene foam).
1)
1. INDOOR UNIT INSTALLATION
Unit: mm
7
>1000mm
>1000mm
>1000mm
>1000mm
MODEL AH
287
245
317
275
MUCSR-48-H6
MUCSR-48/60-H6T
MUCSR-24/30/36/42-H6
Unit:mm
Tubing side Drain side
950(Panel)
950(Panel)
840(Body)
840(Body)
780(Hook-location)
680(Hook-location)
Connecting point of drain pipe
Connecting point
of refrigerant pipe
Connecting point
of refrigerant pipe
(Liquid side)
(Gas side)
Panel
Outlet
Outlet Inlet
880mm(Ceiling hole)
Ceiling
>2500mm
Ground
INSTALLATION MANUAL
Fig.5-5 Fig.5-4
Fig.5-9 Fig.5-8
1.3 Install The Panel
Remove the air-in grill.
Never put the panel face down on floor or against the
wall, or on bulgy objects.
Never crash or strike it.
Slide two grill switches toward the middle at the same time,
and then pull them up. (Refer to Fig.5-7)
Draw the grill up to an angle of about 45, and remove it.
(Refer to Fig.5-8)
Remove the installation covers at the four corners
Wrench off the bolts, loose the rope of the installation covers,
and remove them. (Refer to Fig.5-9)
1
2
CAUTION
Fig.5-6
Fig.5-7
1.2 Install the main body
Cut a quadrangular hole of 880x880mm in the ceiling
according to the shape of the installation paper board.
(Refer to Fig.5-2)
The center of the hole should be at the same position of
that of the air conditioner body.
Determine the lengths and outlets of the connecting pipe,
drainpipe and cables.
To balance the ceiling and to avoid vibration, please
enforce the ceiling when necessary.
Adjust the hexangular nuts on the four installation hooks
evenly, to ensure the balance of the body.
If the drainpipe is awry, leakage will be caused by the
malfunction of the water-level switch.
Adjust the position to ensure the gaps between the body
and the four sides of ceiling are even. The body's lower
part should sink into the ceiling for 10~12 mm (Refer to
Fig.5-4) .
In general, L is half of the screw length of the installation
hook. (Refer to Fig.5-4)
Locate the air conditioner firmly by wrenching the nuts
after having adjusted the body's position well. (Refer to
Fig.5-5)
Select the position of installation hooks according to the
hook holes on the installation board.
Drill four holes of
Ø
12mm, 45~50mm deep at the selected
positions on the ceiling. Then embed the expansible
hooks (fittings).
Face the concave side of the installation hooks toward the
expansible hooks. Determine the length of the installation
hooks from the height of ceiling, then cut off the
unnecessary part.
If the ceiling is extremely high, please determine the
length of the installation hook according to facts.
1
2
3
1
2
3
4
New built houses and ceilings
In the case of new built house, the hook can be embedded
in advance (refer to 2 mentioned above). But it should be
strong enough to bear the indoor unit and will not become
loose because of concrete shrinking.
After installing the body, please fasten the installation paper
board onto the air conditioner with bolts(M6X12) to
determine in advance the sizes and positions of the hole
opening on ceiling. (Refer to Fig.5-6)
Refer to 3 above for installation.
Remove the installation paper board.
Please first guarantee the flatness and horizontal of
ceiling when installing it.
Refer to 1 mentioned above for others.
After installing the body, the four bolts(M6x12)must be
fastened to the air conditioner onto ensure the body is
grounded well.
CAUTION
The existing ceiling (to be horizontal)
8
INSTALLATION MANUAL
Adjust the four panel hook screws to keep the panel
horizontal, and screw them up to the ceiling evenly. ( Refer to
Fig.5-10.3)
Regulate the panel in the direction of the arrow in Fig.5-10.4
slightly to fit the panel's center to the center of the ceiling's
opening. Guarantee that hooks of four corners are fixed well.
Keep fastening the screws under the panel hooks, until the
thickness of the sponge between the body and the panel's
outlet has been reduced to about 4~6mm. The edge of the
panel should contact with the ceiling well. (Refer to Fig.5-11)
4
5
6
Fasten the rope of installation cover on the bolt of the
installation cover. (Refer to Fig.5-14-left)
Press the installation cover into the panel slightly. (Refer to
Fig.5-14-right)
Malfunction described in Fig.5-12 can be caused by
inappropriate tightness the screw.
If the gap between the panel and ceiling still exists after
fastening the screws, the height of the indoor unit should
be modified again. ( Refer to Fig.5-13-left)
You can modify the height of the indoor unit through the
openings on the panel's four c orners, if the lift of the
indoor unit and the drainpipe is not influenced (Refer to
Fig.5-13-right).
Hang the air-in grill to the panel, then connect the lead
terminator of the swing motor and that of the control box
with corresponding terminators on the body respectively.
Relocate the air-in grill in the procedure of reversed order.
Relocate the installation cover.
Fig.5-10
Tubing joint
Outlet joint
Hook panel
Water-receiver
Swing Motor
Hook-bolt
Cross-screwdriver
Do not coil the wiring of the swing motor into the seal
sponge.
Install the panel
Align the swing motor on the panel to the tubing joints of the
body properly. ( Refer to Fig.5-10)
Fix hooks of the panel at swing motor and its opposite sides
to the hooks of corresponding water receiver. ( Refer to
Fig.5-10.1) Then hang the other two panel hooks onto
corresponding hangers of the body. ( Refer to Fig.5-10.2)
3
CAUTION
panel sponge
body
Ceiling
panel
panel foam1 air out
Fan panel foam 2
Loosen upper nut
Adjust lower nut
4 - m m 6
outlet foam
Fig.5-12
Fig.5-14
Fig.5-11
Fig.5-13
Installation cover’s rope
Tap Screw Slide the four sliders
in the corresponding
channel when installing
the cover
9
INSTALLATION MANUAL
<500mm
m m 0 5
7 <
Lean over 1/50
Pump-pipe clasp
(the fittings)
1-1.5m
Fig.5-15
Fig.5-16
All the pictures in this manual are for explanation purpose only.
They may be slightly different from the air conditioner you
purchased(depend on model).The actual shape shall prevail.
NOTE
Test cap
C
L
O
S
E
D
O
P
E
N
C
L
O
S
E
D
O
P
E
N
Drainage test Drainage test
Check whether the drainpipe is unhindered.
New built house should have this test done before paving
the ceiling.
The unit with pump.
Remove the test cover, and stow about 2000ml water to the
water pan.
1
Operate the air conditioner in "COOLING" mode. The sound of
the drain pump shall be heard. Check whether the water is
discharged well (1 min lag is possible, according to the length of
the drain pipe), and check whether the water leaks from the
joints.
2
Power off the air conditioner and recover the cap.
3
10
INSTALLATION MANUAL
model 24 to 30 Series A=160mm; Series B=75mm
model 36 to 60 Series A=160mm; Series B=95mm
The air volume in duct is around 300-360m3/h for model 24
to 30 unit.
The air volume in duct is around 400-640m3/h for model 36
to 60 unit.
The max. length of duct is 2m.
The original air outlet with the same direction of duct should
be sealed In case of two duct connection.
The air volume in one duct is around 200-260m3/h for model
24 to 30 unit.
The air volume in one duct is around 300-500m3/h for model
36 to 60 unit.
The max. length of duct is 1.5m for one duct.
The original air outlet with the same direction of duct should
be sealed.
Fig.5-19
Fig.5-18
One-way
Two-way
In case of one duct connection In case of two duct connection
NOTE
Fig.5-17
1.4 Install the distribution duct
Conditioned air can be distributes by means of a distribution duct.
80mm
80mm
Ø75mm
11
Model (24-60)
2.1 Precautions for selecting the location
2.2 Figure of body size
2. OUTDOOR UNIT INSTALLATION
1) Choose aplace solid enough to bear the weight and vibration of
the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or
the operation noise will not cause a nuisance to the neighbours
of the user.
3) Avoid places near a bedroom and the like, so that the operation
noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out
of the site.
5) There must be sufficient space for air passage and no
obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas
leakage in a nearby place.
7) Install units, power cords and inter-unit wire at least 3m away from
television and radio sets. This is to prevent interference to images
and sounds. (Noises may be heard even if they are more than 3m
away depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate
gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the
unit anything which must be kept away from moisture.
Cannot be installed hanging from ceiling or stacked.NOTE:
When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
- To prevent exposure to wind, install the outdoor unit with its suction
side facing the wall.
- Never install the outdoor unit at a site where the suction side may
be exposed directly to wind.
- To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
- In heavy snowfall areas, select an installation site where the snow
will not affect the unit.
CAUTION
-Construct alarge canopy.
- Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
INSTALLATION MANUAL
12
MODEL
MUCSR-24-H6
MUCSR-12/18-H6
MUCSR-48/60-H6T
MUCSR-48-H6
MUCSR-30/36/42-H6
W
D H
W1
A
B
800
333 554
870
514
340
845
363
914
540
350
946
410
1030
673
403
W
D
H
W1
A
B
952
415
1333
1045
634
404
MODEL
Unit:mm
Unit:mm
2.3 Installation guidelines 2.4 Outdoor unit installation
When installing the outdoor unit, refer to "Precautions for
selecting the location" .
Check the strength and level of the installation ground so that
the unit will not cause any operating vibration or noise after
installed.
Fix the unit securely by means of the foundation bolts.
(Prepare 4 sets of M8 or M10 foundation bolts, nuts and
washers each which are available on the market.)
Where a wall or other obstacle is in the path of outdoor unit
inlet or outlet airflow, follow the installation guidelines below.
For any of the below installation patterns, the wall height on the
outlet side should be 1200mm or less.
's
1) Installing outdoor unit
2) Drain work
If drain work is necessary, follow the procedures below.
'
Use drain plug for drainage.
If the drain port is covered by a mounting base or floor surface,
place additional foot bases of at least 30mm in height under the
outdoor unit s feet.
In cold areas, do not use a drain hose with the outdoor unit.
(Otherwise, drain water may freeze, impairing heating
performance.)
Drain port
Bottom frame Seal
Drain plug
Hose
Wall facing one side
Walls facing three sides
Walls facing two sides
1200
or less
Direction
of air
More than 100 More than 350
Side view
Top view
More than 50
More
than 100
More
than 350
More than 50
Top view
More than 50
More than 100
More than 350
Unit:mm
Fix with bolts
INSTALLATION MANUAL
13
3. INSTALL THE REFRIGERANT PIPE
Execute heat insulation work completely on both sides of the
gas piping and liquid piping. Otherwise, this can sometimes
result in water leakage.
(When using a heat pump, the temperature of the gas piping can
reach up to approximately 120 . Use insulation which is
sufficiently resistant.)
Before rigging tubes, check which type of refrigerant is used.
All field piping must be provided by a licensed refrigeration
technician and must comply with the relevant local and
national codes.
Use a pipe cutter and flare suitable for used refrigerant.
Do not mix anything other than the specified refrigerant, such
as air, etc.., Inside the refrigerant circuit.
Coat the flare both inside and ouside with oil or oil .ether ester
If the refrigerant gas leaks during the work, ventilate the area.
A toxic gas is emitted by the refrigerant gas being exposed to
a fire.
Make sure there is no refrigerant gas leak. A toxic gas may be
released by the refrigerant gas leaking indoor and being
exposed to flames from an area heater, cooking stove, etc.
Also, in cases where the temperature and humidity of the
refrigerant piping sections might exceed 30 or Rh80%,
reinforce the refrigerant insulation(20mm or thicker).
Condensation may form on the surface of the insulating material.
Only use annealed material for flare conncetions.
Coat here with ether oil or ester oil
Precautions
3.1 Flaring the pipe end
1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing downward so that the
chips do not enter the pipe.
5) Check that the flaring is properly made.
Refer to the table below for the dimensions of flare nuts spaces
and the appropriate tightening torque. (Overtightening may
damage the flare and cause leaks.)
Pipe gauge
(mm)
Outer diam.
(mm)
Tightening torque
A(mm)
Max.
1.3
1.6
1.8
2.2
Min.
0.7
1.0
1.0
2.0
Flare dimension
A(mm) Flare shape
O6.35
O6.35
15~16 N. m
(153~163 kgf.cm) 8.3~8.7
12.0~12.4
15.4~15.8
18.6~19.0
22.9~23.3
25~26 N. m
(255~265 kgf.cm)
35~36 N. m
(357~367 kgf.cm)
45~47 N. m
(459~480 kgf.cm)
97.2~118.6 N. m
(990~1210 kgf.cm)
O9.52
O9.52
O12.7
O12.7
O15.9
O19.1
O15.9
R0.4~0.8
45 2
90 4
A
o
o
1 Torque wrench
2 Flare nut
3 Piping union
4 Spanner
12
34
Align the centres of both flares and tighten the flare nuts 3 or 4
turns by hand. Then tighten them fully with the torque wrenches.
3.2 Refrigerant piping
Check whether the height drop between the indoor unit and
outdoor unit, and the length of refrigerant pipe meet the following
requirements:
Cut exactly at
right angles. Remove burrs.
Flare s inner surface
must be flaw-free
'
The pipe end must
be evenly flared in a
perfect circle.
Make sure that the
flare nut is fitted.
3) Put the flare nut on the pipe.
4) Flare the pipe.
Die
Copper pipe
A
Set exactly at the position shown below.
INSTALLATION MANUAL
14
Model Max.allowable
piping length
25m
50m
Max.allowable
piping height
10m
25m
30m
65m
20m
30m
MUCSR-12-H6
MUCSR-18-H6
MUCSR-24/30-H6
MUCSR-36/42/48-H6
MUCSR-48/60-H6T
3.3 Purging air and checking gas leakage
When piping work is completed, it is necessary to purge the
air and check for gas leakage.
WARNING
Do not mix any substance other than the specified refrigerant
into the refrigeration cycle.
When refrigerant gas leaks occur, ventilate the room as soon as
possible.
The specified refrigerant should always be recovered and never
be released directly into the environment.
Use a vacuum pump for the specified refrigerant. Using the
same vacuum pump for different refrigerants may damage the
vacuum pump or the unit.
If using additional refrigerant, perform air purging from the
refrigerant pipes and indoor unit using a vacuum pump, than
charge additional refrigerant.
Use a hexagonal wrench(4mm) to operate the stop valve rod.
All refrigerant pipe joints should be tightened with a torque
wrench at the specified tightening torque.
1) Connect projection side of charging hose (which comes from
gauge manifold) to gas stop valve's service port.
2) Full open gauge manifold's low-pressure valve (Lo) and
completely close its high-pressure valve (Hi)
(High-pressure valve subsequently requires no operation.)
3) Do vacuum pumping and make sure that the compound
pressure gauge reads -0.1MPa (-76cmHg).*1
4) Close gauge manifold's low-pressure valve (Lo) and sop
vacuum pump.
(Keep this state for a few minutes to make sure that the
compound pressure gauge pointer does not swing back.)*2
5) Remove caps from liquid stop valve and gas stop valve.
6) Turn the liquid stop valve's rod 90 degrees counterclockwise
with a hexagonal wrench to open valve.
Close it after 5 seconds, and check for gas leakage.
Using soapy water, check for gas leakage from indoor unit's
flare and outdoor unit's flare and valve rods.
After the check is complete, wipe all soapy water off.
7) Disconnect charging hose from gas stop valve's service port
then fully open liquid and gas stop valves.
(Do not attempt to turn valve rod byond its stop.)
8) Tighten valve caps and service port caps for the liquid and
gas stop valves with a torque wrench at the specified torques.
*1. Pipe length vs. Vacuum pump run time
3.5 Refrigerant pipig work
Pipe length and refrigerant amount:
Connective
pipe length
3.4 Additional refrigerant charge
CAUTION
Refrigerant may only be charged after performing the leak
test and the vacuum pumping.
Check the type of refrigerant to be used on the machine
nameplate. Charging with an unsuitable refrigerant may
cause explosions and accidents, so always ensure that the
appropriate refrigerant is charged.
Refrigerant containers shall be opened slowly.
The outdoor unit is factory charged with refrigerant. Calculate the
added refrigerant according to the diameter and the length of the
liquid pipe of the outdoor unit/indoor unit connection.
1) Caution on the pipe handling
Protect the open end of the pipe against dust and moisture.
All pipe bends should be as gentle as possible. Use a pipe
bender for bending.
Be sure to add the proper amount of additional refrigerant.
Failure to do so may result in reduced performance.
Pipe length Up to 15m More than 15m
Not less than 15minNot less than 10 minRun time
*2. If the compound pressure gauge pointer swings back,
refrigerant may have water content or a loose pipe joint may
exists. Check all pipe joints and retighten nuts as needed,
then repeat steps 2) through 4).
Be sure to
place a cap.
If no flare cap is
available, cover the
flare mouth with
tape to keep dirt or
water out.
Wall
Rain
Less
than 5m
More
than 5m
Air purging
method
Use vacuum
pump.
Use vacuum
pump.
Additional amount of refrigerant to be charged
R410A: (L-5)x15g/m R410A: (L-5)x30g/m
Liquid side:
INSTALLATION MANUAL
9.52mm (3/8")
Liquid side:
6.35mm (1/4")
15
For local insulation, be sure to insulate local piping
all the way into the pipe connections inside the unit.
Exposed piping may cause condensation or may
cause burns when touched.
Make sure that no oil remains on plastic parts of the
decoration panel (optional equipment).
Oil may cause degradation and damage to plastic
parts.
1 Piping insulation material(field supply)
2 Flare nut connection
3 Insulation for fitting (field supply)
4 Piping insulation material (main unit)
5 Indoor unit
6 Clamp (field supply)
A Turn seams up
B Attach to base
C Tighten the part other than the piping insulation material
Piping insulation procedure
Gas piping Liquid piping
11
66
66
44
55
33
22
AA
CC
BB
2) Be sure to insulate both the gas and liquid piping. Use
separate thermal insulation pipes for gas and liquid
refrigerant pipes. See the figure below.
Inter-unit wire
Liquid pipe
Liquid pipe
insulation
Drain hose
Finishing tape
Gas pipe
insulation
Gas pipe
4. CONNECT THE DRAIN PIPE
INSTALLATION MANUAL
4.1 Installation of drain piping
Install the drain piping as shown in figure below and take measures
against condensation. Improperly rigged piping could lead to leaks
and eventually wet furniture and belongings.
- Keep piping as short as possible and slope it downwards at a
gradient of at least 1/100 so that air may not remain trapped
inside the pipe.
- Keep pipe size equal to or greater than that of the connecting
pipe (PVC pipe, nominal diameter 20mm in, outside diameter
25mm).
- Push the drain hose as far as possible over the drain socket,
and tighten the metal clamp securely.
- If the drain hose cannot be sufficiently set on a slope, fit the
hose with drain raising piping (field supply).
- Insulate the drain hose inside the building.
1 Hanging bar
2 1/100 gradient
1 Drain socket (attached to the unit)
2 metal clamp
3 Drain hose
4 Insulation (field supply)
- Make sure that heat insulation work is executed on the
following 2 spots to prevent any possible water leakage due
to dew condensation.
1 Indoor drain pipe.
2 Drain socket.
1 2 3 4
1-1.5m 1
2
×
4.2 Install the drain pipes.
16
INSTALLATION MANUAL
- Connect the drain hose to the drain raising pipes, and
insulate them.
- Connect the drain hose to the drain outlet on the indoor unit,
and tighten it with the clamp.
4.3 How to perform piping
Precautions
- Install the drain raising pipes at a height of less than 530 mm.
- Install the drain raising pipes at a right angle to the indoor
unit and no more than 300 mm from the unit.
- To prevent air bubbles, install the drain hose level or slightly
tilted up (<75 mm).
- The incline of drain hose should be 75 mm or less so that the
drain socket does not have to withstand additional force.
- To ensure a downward slope of 1:100, install hanging
bars every 1 to 1.5 m.
- When unifying multiple drain pipes, install the pipes as
shown in figure below. Select converging drain pipes whose
gauge is suitable for the operating capacity of the unit.
1 Ceiling slab
2 Hanger bracket
3 Adjustable range
4 Drain raising pipe
5 Drain hose
6 Metal clamp
1 T-joint converging drain pipes
1
2
0~75
5
1~1.5m
300
654
3
220
750
530
0-530
100
1
1
Drain piping connections
Do not connect the drain piping directly to sewage
pipes that smell of ammonia. The ammonia in the
sewage might enter the indoor unit through the drain
pipes and corrode the heat exchanger.
Keep in mind that it will become the cause of getting
drain pipe blocked if water collects on drain pipe.
Unit: mm
Unit: mm
Add approximately 1L of water gradually through the air discharge
outlet.
Method of adding water (see the figure below)
4.4 Testing of drain piping
After the piping work is finished, check if drainage flows smoothy.
1 Plastic watering can(tube should be about 100 mm long)
2 Water-receiver
1 2
100
When exlectric wiring work is finished, check drainage flow during
COOL running, exlplained in "Test operation" on page 16.
Fresh air intake (φ65)
106
106
75
65
Unit: mm
17
5. ELECTRIC WIRING WORK
General instructions
All field wiring and components must be installed by a licensed
electrician and must comply with relevant European and national
regulations.
Use copper wire only.
A circuit breaker capable of shutting down power supply to the
entire system must be installed.
Note that the operation will restart automatically if the main
power supply is turned off and then turned back on again.
Be sure to ground the air conditioner.
Do not connect the ground wire to gas pipes, water pipes,
lightning rods, or telephone ground wires.
- Gas pipes: might cause explosions or fire if gas leaks.
-.
-T
.
Water pipes: no grounding effect if hard vinyl piping is used
elephone ground wires or lightning rods: might cause
abnormally highelectric potential in the ground during
lightning storms
Follow the 'Wiring diagram' attached to the unit body to wire the
outdoor unit, indoor units and the remote controller.
The specification of power
Minimum norminal cross-sectional
area of conductors:
Rated current
of appliance
(A)
Nominal cross-sectional
area
(mm2)
<6 0.75
>6 and <10 1.0
>10 and <16 1.5
>16 and <25 2.5
>25 and <32 4.0
>32 and <45 6.0
>45 and <60 10.0
NOTE:
The cable size and the current of the fuse or switch are determined by the
maximum current indicated on the nameplate which located on the side panel
of the unit. Please refer to the nameplate before selecting the cable, fuse and
switch.
INSTALLATION MANUAL
18
Model
INDOOR
UNIT
POWER
Phase 1-phase 1-phase
Frequency and
Voltage 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz
POWER
WIRING (mm
2
) 3×1.0 3×1.0
CIRCUIT
BREAKER/
Fuse (A) 15/10 15/10
OUTDOOR
UNIT
POWER
Phase 1-phase 1-phase 1-phase
Frequency and
Voltage 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 380-420V, 50Hz
POWER
WIRING (mm
2
) 3×2.5 3×2.5 3×4.0
CIRCUIT
BREAKER/
Fuse (A) 20/16 30/20 40/30
Indoor/Outdoor Connecting
Wiring (mm
2
) 4×1.5 2×0.75 (Shielded) 2×0.75 (Shielded) 2×0.75 (Shielded) 2×0.75 (Shielded)
3×6.0 5×2.5
40/35 30/25
MUCSR-12-H6 MUCSR-18/24-H6 MUCSR-30/36-H6 MUCSR-42/48-H6
1-phase
3×1.0
15/10
1-phase
MUCSR-48/60-H6T
1-phase
3×1.0
15/10
3-phase
INSTALLATION MANUAL
Connecting wiring
19
INDOOR UNIT
OUTOOR UNIT
LN S
LNS
L(1)
N(2)
OUTOOR UNIT
INDOOR UNIT INDOOR UNIT
230 Vac
50 Hz
230 Vac
50 Hz 230 Vac
50 Hz
230 Vac
50 Hz 230 Vac
50 Hz
400 Vac
50 Hz
230 Vac
50 Hz
Note: Only Twin (2x1) Note: Only Twin (2x1)
OUTOOR UNIT
INDOOR UNIT INDOOR UNIT
MUCSR-12-H6 (*)
MUCSR-18/24/30/36/42/48-H6 MUCSR-48/60-H6T
* Model MUCSR-12-H6 does not support Twin function
Remote ON/OFF signal and Alarm
CN23 CN33
ON/OFF ALARM
JR6
Indoor Unit Main PCB To use the signal ON / OFF you should cut away the jumper JR6 in indoor unit main PCB.
The operation is as follows:
- With the unit running if the contact CN23 opens unit stops and remote control is locked,
CP shown in the display.
-With the unit stoped if the contact CN23 opens unit will continue stop and remote control
is locked, CP shown in the display.
The alarm signal provides an output of 230Vac when the unit indicates an error code.
NOTE: Only CP shown in the display if the unit has a digital display.
The wired remote control KJR-120C (optional) also shows the CP code.
INSTALLATION MANUAL
20
How to connect wiring
Precautions
Remove the control box lid of the indoor unit.
Remove the cover of the outdoor unit.
Follow the "Wiring diagram label" attached to the indoor unit's
Securely fix the wires with a field supplied champ.
Attach the cover of the outdoor unit.
Observe the notes mentioned below when wiring to the power
supply terminal board.
Use the specified electric wire. Connect the wire securely to
the terminal. Lock the wire down without applying excessive
force to the terminal. (Tightening torque: 1.31N.m 10%).
- Do not connect wires of different gauge to the same power
supply terminal. (Looseness in the connection may cause
overheating.)
- When connecting wires of the same gauge, connect them
according to the figure.
1
- When attaching the control box lid, make sure not to pinch
any wires.
- After all wiring connections are done, fill in any gaps in the
casing wiring holes with putty or insulation material (field
supply) thus to prevent small animals or dirt from entering
the unit from outside and causing short circuits in the control
box.
Do not connect wires of different gauge to the same grounding
terminal. Looseness in the connection may deteriorate the
protection.
Use only specified wires and tightly connect wires to the terminals.
Be careful that wires do not place external stress on the terminals.
Keep wiring in neat order so that they do not obstruct other
equipment such as popping open the service cover. Make sure
the cover closes tight. Incomplete connections could result in
overheating, and in the worst case, electric shock or fire.
2
3
Cover
Bolts
control box lid to wire the outdoor unit, indoor unit and the
remote controller.
Note
Control and settings
For more information, please contact the after-sales service Mundoclima, with your sales man or visit www.mundoclima.com in the corresponding
model section you will find the parameters setting manual.
The capacity of the unit, the address of the unit, temperature compensation, etc. it can be setting by remote control RG57 or by indoor dip-switch.
- The unit capacity should not be modified without permission of the manufacturer.
- Setting is not allowed when the unit is running.
- The address setting of the unit is only necessary if centralized control CCM is connected.
- Twin systems must be set as Master unit and the other as Slave, do the setting by RG57 control or by indoor dip-switch.
Every air-conditioner in network has only one network address to distinguish
each other. Address code of air-conditioner in LAN is set by code switches
S1 & S2 on the Main Control Board of the indoor unit, and the set range is 0-63.
Note: Address setting is only required if you connect a
centralized controller.
SW5
Master / Slave set by indoor dip-switch:
Network address set by indoor dip-switch:
By default, all the units are configured for use in 1x1 systems, to set an indoor unit
of a Twin system (2x1) by micro-switch on the main board, you must set the micro-
switch SW5 so as It is shown in the image on the left.
There are two combinations of the micro-switch to assign the master unit (the two serve equally).
The adjustment should be made with disconnected power supply unit.
The adjustment should be made with disconnected power supply unit.
INSTALLATION MANUAL
21
6. REFRIGERANT PIPE (the unit with the twins
function)
6.1 Length and drop height permitted of the refrigerant piping
Note: Reduced length of the branching tube is the 0.5m of the
equivalent length of the pipe.
H1<30m
H2<0.5m
L
L1
L2
The line branch pipe
Outdoor unit
Indoor unit
Indoor unit
Note The indoor units should be installed equivalently at the
both side of the U type branch pipe.
6.2 Size of joint pipes for indoor unit
Size of joint pipes for indoor unit
Size of joint pipes for outdoor unit
6.3 Size of joint pipes for outdoor unit
Base on the following tables, select the diameters of the outdoor
unit connective pipes. In case of the main accessory pipe large
than the main pipe, take the large one for the selection.
6.4 Refrigerant amount to be added
Calculate the added refrigerant according to the diameter and
the length of the liquid side pipe of the outdoor/indoor unit
connection. The refrigerant is R410A.
The branching pipe must be installed horizontally, error angle
of it should not large than 10 Otherwise, malfunction will be
caused.
o.
U-shaped branching pipe
Adirection view
Horizontal surface
Wrong Correct
1
2
3
4
5
6
7. TEST OPERATION
Refer to ''For the following items, take special care during construction
and check after installation is finished'' on page 4.
After finishing the construction of refrigerant piping, drain piping, and
electric wiring, conduct test operation accordingly to protect the unit.
Make sure the control box lids are closed on the indoor and outdoor
units.
Open the gas side stop valve.
Open the liquid side stop valve.
Electrify crank case heater for 6 hours.
Set to cooling operation with the remote controller and start
operation by pushing ON/OFF button.
Turn off the main power supply after operation.
Check the following points. If there is any malfunction, please
resolve it according to the chapter "Troubleshooting" in the
"Owner's Manual".
The indoor unit
Whether the switch on the remote controller works well.
Whether the buttons on the remote controller works well.
Whether the air flow louver moves normally.
Whether the room temperature is adjusted well.
Whether the indicator lights normally.
Whether the temporary buttons works well.
Whether there is vibration or abnormal noise during operation.
- Whether the drainage flows smoothly.
-
-
-
-
-
-
-
The outdoor unit
Whether there is vibration or abnormal noise during operation.
Whether the generated wind, noise, or condensed of by the air
conditioner have influenced your neighborhood.
Whether any of the refrigerant is leaked.
-
-
-
A protection feature prevents the air conditioner from being
activated for approximately 3 minutes when it is restarted
immediately after shut off.
(Refer to pag. 20)
Pipe length
Drop
height
PipingMax value
Total pipe length (Actual)
(farthest from the line pipe branch)
(farthest from the line pipe branch)
Indoor unit-outdoor unit drop height
Indoor unit to indoor unit drop height
L1-L210m
L+L1+L2
65m
18K+18K
L1;L215m
H1
H2
30m
0.5m
24K+24K
30K+30K
Size of main pipe(mm)
Size of main pipe(mm)
Model
24K
48K
15.9 (5/8)
15.9 (5/8)
9.5 (3/8)
9.5 (3/8)
18K
36K
12.7 (1/2)
15.9 (5/8)
6.35 (1/4)
9.5 (3/8)
30K
60K
15.9 (5/8)
15.9 (5/8)
9.5 (3/8)
9.5 (3/8)
FQZHN-01D
FQZHN-01D
Liquid side
Liquid side
Available branching pipe
The 1st branching pipe
Gas side
Gas side
FQZHN-01D
FQZHN-01D
FQZHN-01D
FQZHN-01D
O
O
O
O
O
O
O
O
O
O
O
O
Model
22
OWNER´S MANUAL
INVERTER SPLIT-TYPE
ROOM AIR CONDITIONER
The design and specifications are subject to
change without prior notice for product improvement.
Read This Manual:
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly.
Just a little preventative care on your part can save you
a great deal of time and money over the life of your air
conditioner.
You'll find manyanswers to common problems in the
chart of troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need to call for
service.
Please read this manual carefully before installing
and using the unit.
NOTE
All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner
you purchased(depend on model).The actual shape shall prevail.
INDOOR UNIT
OUTDOOR UNIT
1
2
3
4
5
6
7
8
9
10
11
12
Air flow louver(at air outlet) Air-in grill
Drain pump(drain water from indoor unit) Display panel
Drain pipe Remote controller
Air outlet Refrigerant pipe
Air filter(inside air-in grill) Air inlet
Air inlet Air inlet Air outlet
3
9
10
11
11
12
1
5
7
8
2
4
6
Fig.1
RESET
TIME ON
TIME OFF
CLOCK
SWING
AIR DIRECTION
OK
ECO
SWING
MODE FAN
SPEED
M
LOCK
C/H
AUTO
COOL
DRY
HEAT
FAN
TEMP
SET
CLOCK
SET
HOUR
FAN SPEED
23
OWNER'S MANUAL
1. IMPORTANT SAFETY INFORMATION
To prevent injury to the user or other people and property
damage, the following instructions must be followed. Incorrect
operation due to ignoring of instructions may cause harm or
damage.
Ask your dealer for installation of the air conditioner.
Incomplete installation performed by yourself may result in a
water leakage, electric shock, and fire.
Ask your dealer for improvement, repair, and
maintenance.
Incomplete improvement, repair, and maintenance may result
in a water leakage, electric shock, and fire.
In order to avoid electric shock, fire or injury, or if you
detect any abnormality such as smell of fire, turn off the
power supply and call your dealer for instructions.
Never let the indoor unit or the remote controller get wet.
It may cause an electric shock or a fire.
Never press the button of the remote controller with a
hard, pointed object.
The remote controller may be damaged.
Never replace a fuse with that of wrong rated current or
other wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break down
or cause a fire.
Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the unit
for cooling precision instruments, food, plants, animals or
works of art.
Before cleaning, be sure to stop the operation, turn the
breaker off or pull out the supply cord.
Otherwise, an electric shock and injury may result.
In order to avoid electric shock or fire, make sure that an
earth leak detector is installed.
Be sure the air conditioner is grounded.
In order to avoid electric shock, make sure that the unit is
grounded and that the earth wire is not connected to gas or
water pipe, lightning conductor or telephone earth wire.
It is not good for your health to expose your body to the
air flow for a long time.
Do not insert fingers, rods or other objects into the air
inlet or outlet.
When the fan is rotating at high speed, it will cause injury.
Never use a flammable spray such as hair spray,lacquer
or paint near the unit.
It may cause a fire.
Never touch the air outlet or the horizontal blades while
the swing flap is in operation.
Fingers may become caught or the unit may break down.
Never put any objects into the air inlet or outlet.
Objects touching the fan at high speed can be dangerous.
Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.
Do not dispose this product as unsorted municipal
waste.Collection of such waste separately for special
treatment is necessary.
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities.
Contact you local government for information regarding the
connection systems available.
If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the
groundeater and get into the food chain, damaging your
health and well-being
To prevent refrigerant leak, contact your dealer.
When the system is installed and runs in a small room, it is
required to keep the concentration of the refrigerant, if by any
chance coming out, below the limit. Otherwise, oxygen in the
room may be affected, resulting in a serious accident.
The refrigerant in the air conditioner is safe and normally
does not leak.
If the refrigerant leaks in the room, contact with a fire of a
burner, a heater or a cooker may result in a harmful gas.
Turn off any combustible heating devices, ventilate the
room, and contact the dealer where you purchased the
unit.
Do not use the air conditioner until a service person confirms
that the portion where the refrigerant leaks is repaired.
The safty precautions listed here are divided into two categories. In
either case, important safty information is listed which must be read
carefull y .
Failure to observe a caution may result in injury or damage
to the equipment.
in death.
The appliance shall be installed in accordance with national
wiring regulations.Failure to observe a warning may result
CONTENTS PAGE
IMPORTANT SAFETY INFORMATION.......................................................9
PARTS NAMES........................................................................................
AIR CONDITIONER OPERATIONS AND PERFORMANCE...........................
HINTS FOR ECONOMICAL OPERATION
....................................................
MAINTENANCE
.......................................................................................
FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES........
TROUBLESHOOTING...............................................................................
CAUTION
CAUTION
WARNING
WARNING
24
25
26
26
27
28
29
ADJUSTING AIR FLOW DIRECTION ......
....................................................
26
24
OWNER'S MANUAL
2. PARTS NAMES
The air conditioner consists of the indoor unit, the outdoor unit,
the connecting pipe and the remote controller.
(Refer to Fig.2-1)
In order to avoid injury, do not remove the fan guard of
the outdoor unit.
Do not operate the air conditioner with a wet hand.
An electric shock may happen.
Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.
Do not place items which might be damaged by moisture
under the indoor unit.
Condensation may form if the humidity is above 80%, the
drain outlet is blocked or the filter is polluted.
After a long use, check the unit stand and fitting for
damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deficiency, ventilate the room
sufficiently if equipment with burner is used together
with the air conditioner.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air flow.
Adverse influence to little children, animals and plants may
result.
Do not allow a child to mount on the outdoor unit or
avoid placing any object on it.
Falling or tumbling may result in injury.
Do not operate the air conditioner when using a room
fumigation - type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of
those who are hypersensitive to chemicals.
Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under the
indoor unit.
It may cause incomplete combuston or deformation of the
unit due to the heat.
Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a
fire may break out.
The appliance is not intended for use by young children
or infirm persons without supervision.
Do not operate your air conditioner in a wet room such
as a bathroom or laundry room.
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
FORCED AUTO
The OPERATION lamp is lit, and the air conditioner will run
under FORCED AUTO mode. The remote controller operation is
enabled to operate according to the received signal.
1
FORCED COOL
The OPERATION lamp flashes, the air conditioner will turn to
FORCED AUTO after it is enforced to cool with a wind speed of
HIGH for 30 minutes. The remote controller operation is
disabled.
OFF
The OPERATION lamp goes off. The air conditioner is OFF
while the remote controller operation is enabled.
2
3
Function indicators on indoor unit display panel
Display panel       Fig.2-1
PRE-DEF indicator(cooling and heating type)
or fan only indicator(cooling only type)
Infrared signal receiver
Operation lamp Timer indicator Alarm indicator
Temporary button
Display panel       Fig.2-2
PRE-DEF indicator(cooling and heating type)
or fan only indicator(cooling only type)
Operation lamp Timer indicator Alarm indicator
Infrared signal receiver
Temporary button
FUNC
Function indicators on indoor unit display panel
       
Display panel       Fig.2-1
PRE-DEF indicator(cooling and heating type)
or fan only indicator(cooling only type)
Infrared signal receiver
Operation lamp Timer indicator Alarm indicator
Temporary button
25
OWNER'S MANUAL
NOTE
Use the system in the following temperature for safe and
effective operation.The Max operation temperature for
the air conditioner.(Cooling/Heating)
3. AIR CONDITIONER OPERATIONS AND
PERFORMANCE
4. HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical operation.
(Refer to corresponding chapterfor details)
1 If air conditioner is used outside the above conditions, it
may cause the unit to function abnormally.
The phenomenon is normal that the surface of air
conditioning may condense water when the relative
larger humidity in room, please close the door and
window.
Optimum performance will be achieved within these
operating temperature range.
2
3
Three-minute protection feature
A protection feature prevents the air conditioner from
being activated for approximately 3 minutes
when it restarts immediately after operation.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start flashing
when power is restored.
To restart operation, push the ON/OFF button on the remote
controller.
Lightning or a car wireless telephone operating nearby may
cause the unit to malfunction.
Adjust the air flow direction properly to avoid winding toward
your body.
Adjust the room temperature properly to get a comfortable
situation and to avoid supercooling and superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or
windows more often than necessary.
Set the timer for the desired operating time.
Never put obstructions near the air outlet or the air inlet. Or it
will cause lower efficiency, even a sudden stop.
Adjust the air flow direction properly to avoid winding toward
your body.
Adjust the room temperature properly to get a comfortable
situation and to avoid supercooling and superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or
windows more often than necessary.
If you don't plan to use the unit for a long time, please
disconnect power and remove the batteries from the remote
controller. When the power switch is connected, some energy
will be consumed, even if the air conditioner isn't in operation.
So please disconnect the power to save energy. And please
switch the power on 12 hours before you restart the unit to
ensure a smooth operation.
A clogged air filter will reduce cooling or heating efficiency,
please clean it once two weeks.
Table 2-1
Cooling operation
Dry operation
Heating operation
Mode
Temperature Outdoor
temperature temperature
Room
0°C ~ 50°C / 32 °F~122°F
-15°C ~ 50°C / 5 °F~122°F
-15°C ~ 24°C / 5 °F~76°F
0°C~30°C
(32°F~86°F)
17°C~32°C
(62°F ~90°F)
17°C~32°C
(62°F ~90°F)
5. ADJUSTING AIR FLOW DIRECTION
While the unit is in operation, you can adjust the air flow louver
to change the flow direction and naturalize the room
temperature evenly. Thus you can enjoy it more comfortably.
Set the air flow direction.
Press the SWING button to adjust the louver to the desired
position and press this button again to maintain the louver at
this position.
Adjust the air flow direction automatically.
Press the SWING button, the louver will swing automatically.
While this function is set, the swing fan of indoor unit runs;
otherwise, the swing fan doesn't run. The swing scale of every
side is 30°. When the air conditioner isn't in operation (including
when TIMER ON is set), the SWING button will be invalid.
Adjust it up and down Fig 5-1
Fig 5-2
Adjust it up and down
5. ADJUSTING AIR FLOW DIRECTION
While the unit is in operation, you can adjust the air flow louver
to change the flow direction and naturalize the room
temperature evenly. Thus you can enjoy it more comfortably.
Set the air flow direction.
Press the SWING button to adjust the louver to the desired
position and press this button again to maintain the louver at
this position.
Adjust the air flow direction automatically.
Press the SWING button, the louver will swing automatically.
While this function is set, the swing fan of indoor unit runs;
otherwise, the swing fan doesn't run. The swing scale of every
side is 30°. When the air conditioner isn't in operation (including
when TIMER ON is set), the SWING button will be invalid.
Adjust it up and down Fig 5-1
Fig 5-2
Adjust it up and down
26
OWNER'S MANUAL
6. MAINTENANCE
CAUTION
Before you clean the air conditioner, be sure the power
supply is off.
Check if the wiring is not broken off or disconnected.
Use a dry cloth to wipe the indoor unit and remote
controller.
A wet cloth may be used to clean the indoor unit if it is
very dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically-treted duster for wiping or leave
such material on the unit for long.
it may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar
solvents for cleaning.
These may cause the plastic surface to crack or deform.
Cleaning the air filter
The air filter can prevent the dust or other particulate from
going inside. In case of blockage of the filter, the working
efficiency of the air conditioner may greatly decrease .
Therefore, the filter must be cleaned once two weeks during
long time usage.
If the air conditioner is installed in a dust place, clean the air
filter frequent.
If the accumulated dust is too heavy to be cleaned, please
replace the filter with a new one(replaceable air filter is an
optional fitting).
Open the air-in grill
Push the grill switches towards the middle simultaneously as
indicated in Fig.6-1. Then pull down the air-in grill.
The control box cables ,which are originally connected with
the main body electrical terminators must be pulled off before
doing as indicated above.
1
2
3
4
Take out the air-in grill (together with the air filter shown in
Fig.6-1).
Pull the air-in grill down at 45 and lift it up to take out the
grill.
Dismantle the air filter.
Clean the air filter
Vacuum cleaner or pure water may be used to clean the air
filter.If the dust accumulation is too heavy , please use soft
brush and mild detergent to clean it and dry out in cool place.
The air-in side should face up when using vacuum cleaner.
(See Fig. 6-3)
The air-in side should face down when using water.
(See Fig. 6-4)
Re-install the air filter.
Install and close the air-in grill in the reverse order of step 1
and 2 and connect the control box cables to the
corresponding terminators of the main body .
5
6
Fig.6-1
Fig.6-2
Fig.6-3
Fig.6-4
Do not dry out the air filter under direct sunshine or with
fire.
CAUTION
Maintenance after a long stop period
(eg. at the beginning of the season)
Maintenance before a long stop period
(eg. at the end of the season)
Check and remove everything that might be blocking inlet
and outlet vents of indoor units and outdoor units.
Clean air filters and casings of indoor units.
Refer to "Cleaning the air filter" for details on how to proceed
and make sure to install cleaned air filters back in the same
position.
Turn on the power at least 12 hours before operating the unit
in order to ensure smoother operation. As soon as he power
is turned on, the remote controller displays appear.
Let the indoor units run in fan only operation for about half a
day in order to dry the interior of the units.
Clean air filters and casings of indoor units. Refer to "
Cleaning the air filter" for details on how to proceed and
make sure to install cleaned air filters back in the same
position.
27
OWNER'S MANUAL
Symptom 4: Noise of air conditioners cooling
Symptom 4.1: Indoor unit
When humidity is high during cooling operation If the interior of
an indoor unit is extremely contaminated, the temperature
distribution inside a room becomes uneven. It is necessary to
clean the interior of the indoor unit. Ask your dealer for details
on cleaning the unit. This operation requires a qualified service
person.
When the system is changed over to heating operation after
defrost operation Moisture generated by defrost becomes
steam and is exhausted.
A continuous low "shah" sound is heard when the system is in
cooling operation or at a stop.
When the drain pump (optional accessories) is in operation,this
noise is heard.
A "pishi-pishi" squeaking sound is heard when the system stops
after heating operation.
Expansion and contraction of plastic parts caused by
temperature change make this noise.
Symptom 4.2: Indoor unit, outdoor unit
A continuous low hissing sound is heard when the system is in
operation.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.
A continuous low hissing sound is heard when the system is in
operation.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.
A hissing sound which is heard at the start or immediately after
stopping operation or defrost operation.
This is the noise of refrigerant caused by flow stop or flow
change.
Symptom 4.3: Outdoor unit
When the tone of operating noise changes.
This noise is caused by the change of frequency.
Symptom 5: Dust comes out of the unit
Symptom 6: The units can give off odours
When the unit is used for the first time in a long time.
This is because dust has gotten into the unit.
The unit can absorb the smell of rooms, furniture, cigarettes,
etc., and then emit it again.
Symptom 7: The outdoor unit fan does not spin.
During operation. The speed of the fan is controlled in order to
optimize product operation.
7. FOLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES
Symptom 1: The system does not operate
Symptom 2: Change into the fan mode during cooling
mode
Symptom 3: White mist comes out of a unit
The air conditioner does not start immediately after the ON/OFF
button on the romote controller is pressed.
If the operation lamp lights, the system is in normal condition.To
prevent overloading of the compressor motor, the air
conditioner starts 3 minutes after it is turned ON.
If the operation lamp and the "
PRE-DEF indicator(cooling and
heating type) or fan only indicator(cooling only type)"
light, it
means you choose the heating model, When just starting, if the
compressor has not started, the indoor unit appears "anti cold
wind" protection because of its overlow outlet temperature.
In order to prevent the indoor evaporator frosting, the system
will change into fan mode automatically, restore to the cooling
mode after soon.
When the room temperature drops to the set temperature, the
compressor goes off and the indoor unit changes to fan mode;
when the temperature rises up, the compressor starts again. It
is same in the heating mode.
Symptom 3.1: Indoor unit
Symptom 3.2: Indoor unit, outdoor unit
When humidity is high during cooling operation If the interior of
an indoor unit is extremely contaminated, the temperature
distribution inside a room becomes uneven. It is necessary to
clean the interior of the indoor unit. Ask your dealer for details
on cleaning the unit. This operation requires a qualified service
person
28
OWNER'S MANUAL
CAUTION
The operation lamp is flashing rapidly (5Hz). This lamp is still
flashing rapidly after turn off the power and turn on again.
(Refer to Table 8-1, Table 8-2 and Table 8-3)
Remote controller receives malfunction or the button does not
work well.
A safety device such as a fuse, a breaker frequently actuates.
Obstacles and water enter the unit.
Water leaks from indoor unit.
Other malfunctions.
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
If the system does not properly operate except the above
mentioned cases or the above mentioned malfunctions is
evident, investigate the system according to the following
procedures. (Refer to Table 8-4)
Please cut off the power supply when appearing the
above malfunction, check if the voltage provided is out of
range, check if the installation of air-conditioner is
correct, then electrify again after 3 minutes power off. If
the problem is still existent, please contact the local
service station or the equipment provider.
Table 7-1a
MALFU NC T ION & PROTECTION DEFINE DISPLAYLED4LED 3LED2LED1
E 8
E1
E 2
E 3
E 4
E 7
E E
E d
F3
F4
In-Outdoor unit COMM. Checking
channel is abnormal
Room TEMP. sensor checking
channel is abnormal
Pipe TEMP. Sensor checking
channel is abnormal(T2)
EPPROM malfunction
Indoor fan motor speed out of control
Water-level alarm malfunction
Outdoor malfunction
Indoor twins communication malfunction
Other malfunction of twins
Light Flashing at 2.5HZ Flashing at 0.5HZ
DIGITAL TUBE
ALARMDEF.FANTIMEROPERATION
Pipe TEMP. Sensor checking
channel is abnormal(T2B)
NO.
1
2
3
4
5
6
7
8
9
10
Table 8-1 Indoor unit error codes
8. TROUBLESHOOTING
8.1 Troubles and causes of air conditioner
29
OWNER'S MANUAL
Run Lamp
(flashes)
1E0 OFF 1 Indoor EEPROM error
2E1 OFF 2 Communication malfunction beetwen indoor and outdoor units
3E3 OFF 4 Indoor fan speed malfunction
4E4 OFF 5 Indoor room temperature sensor (T1) open circuit or short circuit
5E5 OFF 6 Indoor coil temperature sensor (T2) open circuit or short circuit
6EC OFF 7 Regfrigerante leakage detection malfunction
7EE OFF 8 Water-level alarm malfunction
8E8 OFF 9 Communication malfunction beetwen two indoor units (for Twin systems)
9E9 OFF 10 Other malfunction of Twins systems
10 Ed OFF 11 Outdoor unit is faulty (for old comunicaction protocol)
11 F0 ON 1 Current overload protection
12 F1 ON 2 Outdoor room temperature sensor (T4) open circuit or short circuit
13 F2 ON 3 Outdoor coil temperature sensor (T3) open circuit or short circuit
14 F3 ON 4 Outdoor discharge temperature sensor (T5) open circuit or short circuit
15 F4 ON 5 Outdoor EEPROM error
16 F5 ON 6 Outdoor fan speed malfunction
17 F6 ON 7 Coil temperature sensor (T2b) open circuit or short circuit (for some Multi)
18 F7 ON 8 Lifting panel comunication checking chanel is abnormal
19 F8 ON 9 Lifting panel malfunction
20 F9 ON 10 Lifting panel is not closed
21 P0 FLASH 1Inverter module IPM protection
22 P1 FLASH 2 High/Low voltage protection
23 P2 FLASH 3 High temperature protection of compressor top
24 P3 FLASH 4Outdoor low temperature protection
25 P4 FLASH 5 Compressor drive error
26 P5 FLASH 6 Mode conflict (for some Multi models)
27 P6 FLASH 7 Low pressure protection of compressor
28 P7 FLASH 8 Sensor of outdoor IGBT is faulty
29 CP -- -- Remote contact OFF enabled
Timer LampCode Description
Table 8-3
Solution
Clean the heat exchanger.
Clean the air filter.
Eliminate all dirties and make air
smooth.
Close doors and windows.
Make curtains in order to shelter from
sunshine.
Reduce heat source.
AC cooling capacity reduces (normal).
Check leakage and rightly recharge
refrigerant.
Symptoms Causes
Unit does not start
Air flowing normally but
completely can't cooling
Units start or stop frequently
Low cooling effect
Low heating effect
Outdoor unit and indoor unit heat
exchanger is dirty.
The air filter is dirty.
Inlet/outlet of indoor/outdoor units is
blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Outdoor temp. is too high.
Leakage of refrigerant or lack of
refrigerant.
Use heating device.
Close doors and windows.
Check leakage and rightly recharge
refrigerant.
Outdoor temperature is lower than 7 C
Doors and windows not completely
closed.
Leakage of refrigerant or lack of
refrigerant.
Power failure.
Power switch is off.
Fuse of power switch may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Temperature is not set correctly.
Be in 3 minutes protection of
compressor.
Refrigerant is too little or too much.
Air or no concretingc gas in the
refrigerating circuit.
Compressor is malfunction.
Voltage is too high or too low.
System circuit is blocked.
Wait for the comeback of power.
Switch on the power.
ReplLocation:
Replace the batterises or check the
controller.
Set the temperature properly.
Wait.
Check leakage, and rightly recharge
refrigerant.
Vacuum and recharge refrigerant.
Maintenance or change compressor.
Install manostat.
Find reasons and solution.
30
OWNER'S MANUAL
Table 8-2 Outdoor unit error codes (Models 18 to 60)
In low ambient cooling mode, the LED displaysLC or alternative displays between running frequency and "LC"
(each displays 0.5s)
1E1
Communication malfunction beetwen indoor and outdoor units
2F0 Current overload protection
3F1 Outdoor room temperature sensor (T4) open circuit or short circuit
4F2 Outdoor coil temperature sensor (T3) open circuit or short circuit
5F3 Outdoor discharge temperature sensor (T5) open circuit or short circuit
6F4 Outdoor EEPROM error
7F5 Outdoor fan speed malfunction
8P0 Inverter module IPM protection
9P1 High/Low voltage protection
10 P3 Outdoor low temperature protection
11 P4
Rotor position protection of compressor
12 P7
Sensor of outdoor IGBT is faulty
13 J0
High temperature position of indoor heat exchanger in heating mode
14 J1
High temperature position of indoor heat exchanger in cooling mode
15 J2 High discharge temperature protection
16 J3 PFC module protection
17 J4 Communication error between outdoor main chip and compressor driven chip IR341
18 J5 High pressure protection
19 J6 Low pressure protection
20 J8 AC voltage protection
DescriptionCode
Symptoms Causes
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
When the automatic mode is
selected, the air conditioner will
automatically change the fan
speed.
When dry operation is selected,
the air conditioner automatically
change the fan speed. The fan
speed can be selected during
"COOL" , "FAN ONLY",
and
"HEAT"
The wire controller signal is
not transmitted even when
the ON/OFF button is pushed.
The power supply is off.
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pressed.
Check whether the signal
transmitter of the wire
controller is properly directed
to the infrared signal receiver
of the indoor unit when the
ON/OFF button is pressed.
Directly transmit the signal transmitter of
the wire controller to the
infrared signal receiver of the
indoor unit, and then repeatly
push the ON/OFF button twice.
The indication on the display
disappears after a lapse of
time.
Check whether the timer
operation has come to an
end when the TIMER OFF
is indicated on the display.
The air conditioner operation will
stop up to the set time
The TIMER ON indicator
goes off after a lapse of
certain time.
Check whether the timer
operation is started when
the TIMER ON is indicated
on the display.
Up to the set time, the
air conditioner will automatically
start and the appropriate
indicator will go off.
The TEMP. indicator does
not come on.
Check whether the MODE
indicated on the display is
FAN ONLY
The temperature cannot be set during
FAN mode.
Table 8-4
Solution
8.2. Troubles and causes of wire controller
Before asking for serving or repairing , check the following points. (Refer to Table 8-4)
Check whether the signal
transmitter of the wire
controller is properly directed
to the infrared signal receiver
of the indoor unit.
31
OWNER'S MANUAL
REMOTE CONTROLLER
32
Please read this manual carefully before installing
and using the unit.
REMOTE CONTROLLER
33
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03 2)
RG57B2/BGE
Remote Controller Specifications
Environment
Signal Receiving
Range
-5 C 60C
~~
MODE
FAN
TEMP
SLEEP
TURBO LED
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
NOTE:
Buttons design is based on typical model and might be slightly different from the actual one you purchased, the
actual shape shall prevail.
All the functions described are accomplished by the unit. If the unit has no this feature, there is no corresponding
operation happened when press the relative button on the remote controller.
When there are wide differences between Remote controller Illustration and "Owner's manual" on
on function description, the description of "Owner's manual" shall prevail.
IMPORTANT NOTE:
This remote controller is able to set different parameters, it has a function selection.
For more information, please contact with Mundoclima after sales service or with your commercial sales.
REMOTE CONTROLLER
34
MODE
FAN
TEMP
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
1
2
4
3
7
8
6
5
9
10
11
12
1
2
Press this button to modify the air conditioner
mode in a sequence of following:
3
MODE Button
4
5
ON/OFF Button
This button turns the air conditioner ON
and OFF.
AUTO
COOL
DRY
HEAT FAN
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
FAN Button
SLEEP Button
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, FAN
SPEED or ON/OFF button is pressed.
Active/Disable sleep function. It can
maintain the most comfortable temperature
and save energy. This function is available
on COOL, HEAT or AUTO mode only .
For the detail, see sleep operation in
USER S MANUAL.
,
,, ,,
,,
,,
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
Operation of buttons
TURBO Button
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temper-
ature at cooling or heating operation in the
shortest time(if the indoor unit does not
support this function, there is no
corresponding operation happened when
pressing this button.)
SLEEP
TURBO LED
SHORTCUT Button
TIMER ON Button
TIMER OFF Button
Used to restore the current settings or
resume previous settings.
On the first time connecting to the power,
if push the SHORTCUT button, the unit
O
will operate on AUTO mode, 26 C, and fan
speed is Auto.
Push this button when remote controller is
on, the system will automatically revert
back to the previous settings including
operating mode, setting temperature, fan
speed level and sleep feature(if activated).
If pushing more than 2 seconds, the system
will automatically restore the current
operation settings including operating mode,
setting temperature, fan speed level and
sleep feature(if activated ).
UP Button( )
Push this button to decrease the indoor
oo
temperature setting in 1 C increments to 17 C.
DOWN Button( )
6
8
9
7
Press this button to initiate the auto-on
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the auto-
timed setting 60 minutes increments.
To cancel the auto-timed program, simply
adjust the auto-on time to 0.0.
Press this button to initiate the auto-off time
sequence. Each press will increase the auto
-timed setting in 30 minutes increments.
When the setting time displays 10.0, each
press will increase the auto-timed setting
60 minutes increments. To cancel the auto-
timed program, simply adjust the auto-off
time to 0.0
Push this button to increase the indoor
oo
temperature setting in 1 C increments to 30 C.
NOTE Temperature contol is not available
in Fan mode.
10
12
Swing Button
Swing Button
Used to stop or start horizontal louver move-
ment or set the desired up/down air flow
direction. The louver changes 6 degree in
angle for each press. If keep pushing more
than 2 seconds, the louver will swing up and
down automatically.
Used to stop or start vertical louver movement
and set the desired left/right air flow direction.
The vertical louver changes 6 degree in angle
for each press. And the temperature display
area of indoor unit displays for one
second. If keep pushing more than 2 seconds,
the vertical louver swing feature is activated.
And the display area of indoor unit displays
, flashes four times, then the tempera-
IIII
ture setting reverts back. If the vertical louver
swing feature is stopped, it displays LC and
remains on for 3 seconds.
NOTE: For some units , the indoor units
display when the swing feature is
activated, and display when the
swing feature is stopped.
,
,
,
,
,
,
,
,,
,
LED Button
Disable/Active indoor screen Display. When
pushing the button, the indoor screen display
is cleared, press it again to light the display.
11
REMOTE CONTROLLER
35
Indicators on LCD
Fan speed indication
Mode display
Information are displayed when
the remote controller is powered
up.
Displayed when data transmitted.
Displayed when remote controller is ON.
Battery display(low battery detection)
Not available for this unit
Not available for this unit
Low speed
Medium speed
High speed
Auto fan speed
Note:
All indicators shown in the figure are for the purpose
of clear presentation. But during the actual operation
only the relative functional signs are shown on the
display window.
Displayed when TIMER ON time is set.
Displayed in Sleep Mode operation.
Not available for this unit
Not available for this unit
Displayed when TIMER OFF time is set.
Show set temperature or room
temperature, or time under TIMER
setting.
AUTO
HEAT FAN
COOL DRY
How to use the buttons
Auto operation
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select Auto.
2. Press the UP/DOWN button to set the
desired temperature. The temperature can
OOO
be set within a range of 17 C~ 30 C in 1 C
increments.
3. Press the ON/OFFbutton to start the air
conditioner.
1. In the Auto mode, the air conditioner can logically
choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed.
It has already been automatically controlled.
3. If the Auto mode is not comfortable for you , the
desired mode can be selected manually.
NOTE
MODE
FAN
TEMP
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
3
1
2
SLEEP
TURBO LED
REMOTE CONTROLLER
36
How to use the buttons
Cooling /Heating/Fan operation
Ensure the unit is plugged in and power is
available.
1. Press the MODE button to select COOL,
HEAT(cooling & heating models only) or
FAN mode.
2. Press the UP/DOWN buttons to set the
desired temperature.
3. Press the FAN button to select the fan speed
in four steps- Auto, Low, Med,or High.
4. Press the ON/OFF button to start the air
conditioner.
The temperature can
OOO
be set within a range of 17 C~ 30 C in 1 C
increments.
In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not
able to control the room temperature either. In this
case, only step 1, 3 and 4 may be performed.
NOTE
MODE
FAN
TEMP
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
4
1
3
2
SLEEP
TURBO LED
Dehumidifying operation
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the
desired temperature.
3. Press the ON/OFF button to start the air
conditioner.
The temperature
OO
can be set within a range of 17 C~ 30 C
O
in 1 C increments.
In the Dehumidifying mode, you can not switch the
fan speed. It has already been automatically controlled.
NOTE
MODE
FAN
TEMP
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
3
1
2
SLEEP
TURBO LED
Adjusting air flow direction
Use the SWING & button to adjust
the desired airflow direction.
1. Up/Down direction can be adjusted with the
button on the remote controller. Each
time when you press the button, the louver
moves an angle of 6 degree. If pressing more
than 2 seconds ,the louver will swing up and
down automatically.
2. Left/Right direction can be adjusted with the
button on the remote controller. Each
time when you press the button, the louver
moves an angle of 6 degree. If pressing more
than 2 seconds ,the louver will swing up and
down automatically.
NOTE: When the louver swing or move to a
position which would affect the cooling
or heating effect of the air conditioner,
it would automatically change the
swing/moving direction.
REMOTE CONTROLLER
2
1
Timer operation
Press the TIMER ON button can set the auto-on
time of the unit. Press the TIMER OFF button
can set the auto-off time of the unit.
1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
the time increases by half an hour between 0
and 10 hours and by one hour between 10 and
24 hours.
3. After setting the TIMER ON ,there will be a one
second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
To set the Auto-on time.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set
desired Auto-off time. Each time you press the
button, the time increases by half an hour
between 0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER OFF ,there will be a
one second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "H " will disappear and the set temperature
will re-appear on the LCD display window.
MODE
FAN
TEMP
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
SLEEP
TURBO LED
When you select the timer operation, the remote controller automatically transmits the
timer signal to the indoor unit for the specified time. Therefore, keep the remote
controller in a location where it can transmit the signal to the indoor unit properly.
The effective operation time set by the remote controller for the timer function
is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20,
21, 22, 23 and 24.
CAUTION
!
Example of timer setting
Start
Off
6 hours later
(Auto-on Operation)
The TIMER ON feature is useful when you want
the unit to turn on automatically before you return
home. The air conditioner will automatically start
operating at the set time.
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting
of starting operation time and the signal "H"
will show on the display area.
2. Press the TIMER ON button to display "6.0H "
on the TIMER ON display of the remote
controller.
3. Wait for 3 seconds and the digital display
area will show the temperature again. The
"TIMER ON" indicator remains on and this
function is activated.
TIMER ON
Example:
Set
37
REMOTE CONTROLLER
38
Stop
On
Set 10 hours later
(Auto-off Operation)
The TIMER OFF feature is useful when you want the
unit to turn off automatically after you go to bed. The
air conditioner will stop automatically at the set time.
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of
stopping operation time and the signal "H" will
show on the display area.
2. Press the TIMER OFF button to display "10H " on
the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
OFF" indicator remains on and this function is
activated.
TIMER OFF
Example:
On
Stop
2 hours later
after setting
Set
To stop the air conditioner 2 hours after setting and
start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display
2.0H on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to display 10H
on the TIMER ON display .
5. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
ON OFF" indicator remains on and this function is
activated.
TIMER OFF TIMER ON
(On Stop Start operation)
This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in
the morning when you wake up or when you return
home.
Example:
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
Start
10 hours later
after setting
Example:
TIMER ON TIMER OFF
(Off Start Stop operation)
This feature is useful when you want to start
the air conditioner before you wake up and
stop it after you leave the house.
To start the air conditioner 2 hours after setting,
and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display
2.0H on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display
5.0H on the TIMER OFF display .
5. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
ON & TIMER OFF" indicator remains on and
this function is activated.
Off Stop
Start
2 hours later
after setting
5 hours later
after setting
Set
REMOTE CONTROLLER
39
8m
Use the remote controller within a distance of 8
meters from the appliance, pointing it towards the
receiver. Reception is confirmed by a beep.
The remote controller can be attached to a wall or pillar
by using a remote controller holder(not supplied,
purchased separately).
Before installing the remote controller, check that the
air conditioner receives the signals properly.
Install the remote controller with two screws.
For installing or removing the remote controller, move
it up or down in the holder.
Location of the remote controller.
Using the remote controller holder(optional)
CAUTIONS
The air conditioner will not operate if curtains,
doors or other materials block the signals from
the remote controller to the indoor unit.
Prevent any liquid from falling into the remote
controller. Do not expose the remote controller
to direct sunlight or heat.
If the infrared signal receiver on the indoor unit
is exposed to direct sunlight, the air conditioner
may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote
controller, either move these appliances or
consult your local dealer.
Do not drop the remote controller. Handle with care.
Do not place heavy objects on the remote controller,
or step on it.
Handling the remote controller
The following cases signify exhausted batteries.
Replace old batteries with new ones.
Receiving beep is not emitted when a signal
is transmitted.
Indicator fades away.
The remote controller is powed by two dry
batteries (R03/LR03X2) housed in the back rear
part and protected by a cover.
(1) Remove the cover in the rear part of the
remote controller.
(2) Remove the old batteries and insert the new
batteries,placing the(+) and (-) ends correctly.
(3) Install the cover back on.
NOTE: When the batteries are removed, the
remote controller erases all programming. After
inserting new batteries, the remote controller
must be reprogrammed.
Replacing batteries
CAUTIONS
Do not mix old and new batteries or batteries
of different types.
Do not leave the batteries in the remote
controller if they are not going to be used for
2 or 3 months.
Do not dispose batteries as unsorted
municipal waste. Collection of such waste
separately for special treatment is necessary.
ASK FOR MORE INFORMATION
Phone: (+34) 93 446 27 80
eMail: info@mundoclima.com
TECHNICAL ASSISTANCE
Phone: (+34) 93 652 53 57
www.mundoclima.com
38

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw MundoClima MUCSR-H6 - Model 24 to 60 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van MundoClima MUCSR-H6 - Model 24 to 60 in de taal/talen: Engels als bijlage per email.

De handleiding is 4,22 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info