656388
3
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
BA SC2819-SC88-SC98-pro MP; DE, GB - 22476 - 2008.05-03
Instruction Manual (Site 1/2)
GB
Time switch (weekly or yearly program)
SC 28.19 pro / SC 88.X0 pro / SC 98.X0 pro 172 419 pro / 179 4X0 pro / 179 6X0 pro
Connection diagram
Directory
1. Safety instructions
35mm (1 channel)
Yearly time switch
70mm (1 channel - 4 channels)
Weekly or yearly time switch
1 channel = Connection A
2 channels = Connection A,B
3 channels = Connection A,B,C
4 channels = Connection A,B,C,D
1. Safety instructions
2. Initial operation
3. DCF (Installation DCF-receiver)
4. Menu overview
5. Symbol legend
6. Key function
7. Handling advice
8. Channel ON OFF / Permanent P
9. Programming menu
10. Standard weekly program
11. Example of a standard weekly
switching time
12. Cycle
13. Cycle options
14. Pulse
15. Priority of the switching programs
16. Special program entry
17. Special program activation
18. Extra switching time
19. Permanentprogram
20. External Input
21. Switchoff warning
22. Channel keys
23. Additional adjustments
24. Program modify
25. Data-key
!
The installation and assembly of electrical equipment must be only carried out only
by a skilled Person! Otherwise fire danger or danger of an electric shock exists!
!
Connect the supply voltage/frequency as stated on the product label!
!
Warranty void if housing opened by unauthorised person!
!
The electronic circuit is protected against a wide range of external influences.
Incorrect operating may occur if external influences exceed certain limits!
2. Initial operation 3. DCF (Installation of the DCF-antenna FU 20)
The time switch is delivered in sleep-mode, the display is switched off.
Press -button for 1 second.
The current date and time is already programmed and European
daylight savings time is activated.
Select the desired language by pressing -buttons and confirm it by
pressing . (Remark: By pressing you move one step backwards
from the current position)
If required, date, time and daylight savings time mode can be adjusted
also by pressing -buttons and a subsequent confirmation with .
The time switch can process the DCF signal.
The antenna FU 20 is not included in delivery of the time switch.
Disconnect power supply voltage
Connect the antenna as indicated by the connection diagram
Connect supply voltage
Antenna symbol (LCD) flashes for approx. 3 minutes
Reception is not possible if severe interference is present
(Permanent flashing of the symbol / The oscillating crystal is used as time base)
Defective wire between antenna and time switch
(No antenna symbol visible / The oscillating crystal is used as time base)
4. Menu overview 5. Symbol legend
Channel is switched ON
Channel is switched OFF
For the current date the “holiday program” / “permanent by date” is activated
Standard programming step
Current state is based on a manual over-ride. The state will be cancelled with the next
programming step
Current state is based on a manual over-ride. The state is permanent until terminated manually
Days of the week Monday, Tuesday, ... Sunday;
The underscores indicate if the program is active for the days above
I
Current state is based on a switching time with pulse function
Z
Current state is based on a switching time with cycle function
W
Weekday function: Switching time is entered by date but is shifted for future years in respect of
the weekday (E.g. Tuesday this year... Tuesday next year).
e
Is displayed if the corresponding channel is activated by the external input.
6. Key function
Element within sub-menu “program delete”
1. To access the Enter-mode (program, adjustments, options) from the automatic-mode.
2. To revert to the beginning of the current (sub-) menu.
F
Switching function / switching time with Easter function: The switching function takes into account
the yearly shift of Easter holiday for future years and changes the date of the switching program
accordingly.
1. To adjust the flashing digit.
2. To scroll through a choice
X
1x-Function active: The switching time will be executed only once.
1. Automatic-mode: To switch the channel ON or OFF until the next programming step occurs.
2. Automatic-mode: A push longer than 3 sec. = Permanent switching status (7).
D
DCF: The time switch receives the signal for the DCF -77 time standard
1. To activate the time switch when operated without power supply.
2. To confirm the selection or the entered data.
The time switch is locked; to unlock the device the PIN has to be entered
7. Handling advice 8. Channel ON OFF / Permanent P 9. Programming menu
The time switch is programmable without external power supply
after pressing the
-button.
To revert one step or one level back while in the Enter-Mode press
.
After completion of a (sub-) menu confirming end will return the
device into the automatic-mode.
With the choice changes from end to continue. By
confirming
continue the time switch returns to the beginning of
the current (sub-) menu.
When confirming end before completion, the time switch returns
to the automatic-mode without saving the entered data.
Channel
ON OFF
By pushing
-buttons a manual switch of the channels
take place. The resulting switching status is marked with
the hand-symbol and remains until the next programming
step occurs. (temporary over-ride)
Permanent switching status
P
By pressing the corresponding channel button
for
more than 3 sec. the channel is permanently switched ON
or OFF. The status remains until the next manual switching
occurs (> 3 sec.). (permanent over-ride)
*within yearly time switches
10. Standard weekly program 11. Example for the programming of STANDARD switching times (ON and OFF)
**The cycle function will only be available if it is activated (point 13)
A. If you want to program a standard weekly switching time (
on, off) confirm Standard with .
B. For regular switching times choose
on or off with -buttons and confirm with .
C. Within this level you activate the days of the week (1…7) on which the switching time should happen.
With
you activate “yes” or deactivate “no” the corresponding date. Confirm each day with .
D. Adjustment of the time: Hours
and . Minutes and .
E. Verify the entered switching time: If the flashing summary of the programming step is correct, verify
on
or
off with . After verification you have the choice between edit/delete and end with .
F. If you want to proceed with programming, confirm
next switching with .
To leave the programming menu confirm
end.
Information: You can easily transfer switching times from one channel to the other if you use the
copy function.
12. Cycle 13. Cycle options
Standard weekly program:
Program -> new program -> channel A/B/C/D -> Standard ->
Special (weekly) program (to be activated by date for the yearly function):
Program -> new program -> channel A/B/C/D -> Special-program -> SP-entry -> program-number ->
For the cycle function it is possibile to enter a periodic switching time. The time switch acts as a recycling timer and
switches between pulse (ON) and pause (OFF). The max. value for pulse and pause is 9:59:59 h:mm:ss.
If you haven’t defined and activated a cycle, the cycle function will not be available as switching time. Therefore you
have to activate and define at least one of the four cycles within menu Options and sub-menu Cycle (point 13).
The cycle switching time will be terminated by another switching time (on, off, pulse) or by another cycle switching
time.
Options -> Cycle -> Cycle 1 - 4 ->
You have the possibility to define 4 different Cycles. For these purposes choose menu Options and sub-menu Cycle. The different
cycles can be activated, defined or deactivated (the max. value for pulse or pause is 9:59:59 h:mm:ss):
Choose menu Options and sub-menu Cycle and confirm with .
Select with -buttons one out of the 4 cycles (Cycle 1 – Cycle 4) and confirm with .
Activate the cycle by changing No to Yes with -buttons and subsequent confirming with .
Define duration of the pulse „on-time“ ( -> …).
Define duration of the pause „off time“ ( -> …).
Confirm End with .
The cycle is now offered within the programming menu.
Further applications of the cycle function in combination with: External Input function and/or Channel keys function.
14. Pulse 15. Priorities of the switching programs
Standard weekly program:
Program -> new program -> channel A/B/C/D -> Standard ->
Special (weekly) program (to be activated by date for the yearly function):
Program -> new program -> channel A/B/C/D -> Special-program -> SP-entry -> program-number ->
The pulse function provides you the opportunity of programming a switching time with a defined duration.
As soon as the pulse-duration has expired the time switch switches OFF automatically (the duration of the pulse is up to
59:59 mm:ss).
Standard switching times, Special programs, Extra switching times and Permanent by date are executed according to their
corresponding priority (by channel and date)
All switching programs except Extra switching times, suspend all other switching programs with lower priority:
highest priority Ö manual over-ride Permanent (3 sec. push)
× Ö Permanent by date
× Ö Extra switching time (yearly time switch)
× Ö Special program 10 by date (yearly time switch)
× Ö Special program ... by date (yearly time switch)
× Ö Special program 01 by date (yearly time switch)
lowest priority Ö Standard weekly program
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Muller SC88 pro bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Muller SC88 pro in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 2,48 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Muller SC88 pro

Muller SC88 pro Gebruiksaanwijzing - Nederlands, Svenska - 4 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info