683890
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
www.hugo-mueller.de BA HUpro GB -22989- 2014-07-V03 - ED - A3 Seite 1
GB
Additional instruction master clock Site 1 / 2
PLEASE NOTE!!!
SAFETY INSTRUCTIONS
(SC 58.17 pro / SC 98.47 pro / SC 53.17 pro / SC 93.47 pro)
Please note the following for masterclock with time switch functionality:
This manual describes only masterclock features. Time switch relevant description can be
found in the standard time switch manual!
Only the connection diagram, initial operations and the safety instructions of this manual is
valid.
!!ATTENTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!!
=> Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
=> Disconnect device from power supply for wiring and installation purposes!!!
=> Defective devices have to be put out of service immediately!!!
Connect the supply voltage/frequency as stated on the product!
Warranty void if housing opened by unauthorised person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if
external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with local building and electrical
codes!
The disposal of the device (and batteries) must be in accordance with the valid environmental and national law!
SC 58.07 pro (DIN rail mounting – master clock)
Technical data slave-clock-line (SL)
SC 58.07 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 35mA
Conn. terminals: 17 / 18
Max. number clocks: approx. 5 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode.
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to terminal no. 17 and 18 of the master clock.
SC 58.08 pro (DIN rail mounting – master clock)
Technical data slave-clock-line (SL)
SC 58.08 pro
Connection diagram
Connection sample
Number of lines: 1
Output voltage: Max. 250V~ (potential-free)
Output current: 1A
Conn. terminals: 2 / 8
Max. number clocks: Depends on the slave clocks
Pulse sequence: Normal operation = 1/min
During adjustment = ca. 6/min
Pulse length: 8 sec.
(Pulse sequence/length adjustable)
PLEASE NOTE: The two relays are
energized alternately every minute.
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to terminal no. 2 and 8 of the master clock.
Power supply slave-clock-line (SL) (See connection diagram on the left)
Connect power supply for clock motor(s) to terminals 1 / 9 and 3 / 7
SC 58.17 pro (DIN rail mounting – master clock with time switch functianality / weekly time switch)
Technical data slave-clock-line (SL)
SC 58.17 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 150mA
Conn. terminals: 17 / 18
Max. number clocks: approx. 20 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave-clock-line (SL) => master clock (See
SC 98.47 pro (DIN rail mounting master clock with time switch functianality / yearly time switch)
Technical data slave-clock-line (SL)
SC 98.47 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 300mA
Conn. terminals: 35 / 36
Max. number clocks: approx. 40 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
(Master clock = terminals 22/23 / Time switch = terminals 4/5).
Connection slave-clock-line (SL) => master clock (See
SC 53.17 pro (19”-housing master clock with time switch functianality / weekly time switch)
Technical data slave-clock-line (SL)
SC 53.17 pro
Connection diagram
SC 53.17: 2 NU-Linie
The signal output for line 1 and line 2 can be configured
independently to emit pulses either every second or every minute!
NOTE! Power supply from a third party supplier:
The usage of a switched-mode power supply to drive the slave clock line
might disturb the reception of the FU 20.00 pro radio receiver. If the radio
receiver has no reception (the green LED on the bottom of the radio
receiver flashes rapidly or not at all) please connect GND of your
switched-mode power supply via an Y-capacitor with protective earth.
Number of lines: 2
Input USL: 24VDC (12VDC/48VDC/60VDC)
(Monitoring USL - switchable)
Output current: up to 1500mA for each line
(Depends on the power supply)
Conn. terminals: See conn. diagram on the left
Max. number clocks: approx. 200 slave clocks
(each line)
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
Module: NT 73 (Power adapter slave line)
Not included in delivery!
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product! (Terminals 32a und 32c).
Connection power supply the slave-clock-line (SL) => master clock
(See connection diagram on the left)
Depending on the specifications of the slave clocks, connect 12VDC; 24VDC; 48VDC; or
60VDC to terminals 26a and 26c.
Check polarity.
For voltages of slave clocks which differ from 24VDC, the dip switches on the PCB have to
be configured as stated within the table on the left.
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to:
Line 1 [L1] => terminals 24a und 24c
Line 2 [L2] => terminals 22a und 22c
Table dip switches
(Power supply monitoring of the slave-clock-
line)
SL S1 S2
SL S1 S2
12VDC ON ON
48VDC OFF ON
24VDC ON OFF
60VDC OFF OFF
SC 93.47 pro (19”-housing master clock with time switch functianality / yearly time switch)
Technical data slave-clock-line (SL)
SC 93.47 pro
Connection diagram
NOTE! Power supply from a third party supplier:
The usage of a switched-mode power supply to drive the slave clock line
might disturb the reception of the FU 20.00 pro radio receiver. If the radio
receiver has no reception (the green LED on the bottom of the radio
receiver flashes rapidly or not at all) please connect GND of your
switched-mode power supply via an Y-capacitor with protective earth.
Number of lines: 1
Input USL: 24VDC (12VDC/48VDC/60VDC)
(Monitoring USL - switchable)
Output current: up to 1500mA
(Depends on the power supply)
Conn. terminals: See conn. diagram on the left
Max. number clocks: approx. 200 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
Module: NT 73 (Power adapter slave line)
Not included in delivery!
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply the master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product! (Terminals 32a und 32c)
Connection power supply slave clockline => master clock
(See connection diagram on the left)
Depending on the specifications of the slave clocks, connect 12VDC; 24VDC; 48VDC; or
60VDC to terminals 26a and 26c.
Check polarity.
For voltages of slave clocks w
be configured as stated within the table on the left.
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to terminal no. 24a and 24c of the master clock.
Table dip switches
(Power supply monitoring of the slave-clock-
line)
SL S1 S2
SC S1 S2
12VDC ON ON
48VDC OFF ON
24VDC ON OFF
60VDC OFF OFF
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Muller SC 58.17 pro bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Muller SC 58.17 pro in de taal/talen: Engels als bijlage per email.

De handleiding is 2,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Muller SC 58.17 pro

Muller SC 58.17 pro Gebruiksaanwijzing - Deutsch - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info