744334
13
Verklein
Vergroot
Pagina terug
1/21
Pagina verder
24
25
DK ENG
We recommend that the stove be installed at least 10-15 cm from masonry in order to allow
heat to circulate and to facilitate the cleaning of the inside and outside of the stove. A layer
of wallpaper on a brick wall is normally regarded as non-ammable material.
The oor
If the stove is installed on a ammable oor, national and local regulations must be observed
with regard to the size of the non-ammable underlying surface that must cover the oor be-
neath the stove.
The underlying surface must naturally be able to bear the weight of the stove and, if ap-
plicable, the steel chimney.
Distance to furniture
We recommend that the stove be installed 900 mm from furniture, but consideration should
also be given to whether furniture, etc., will dry out as a result of its proximity to the stove.
The distance to ammable material in front of the stove is 900 mm.
A wood-burning stove gets hot when it is red. Caution must therefore be observed, par-
ticularly with regard to children touching the stove.
1.5 The chimney
If local regulations permit, the stove may be connected to a chimney already serving anoth-
er replace (such as an oil-burning stove or another wood-burning stove). Attention should
be paid to any requirements concerning the location of ue pipes if two or more replaces
are connected to the same chimney.
The wood-burning stove must never be connected to a chimney to which a gas-burning stove
is already connected. An ecient, modern stove places great demands on the chimney, so have
a chimney sweep check the condition of your chimney.
The aperture of the chimney must comply with national and local regulations. In general,
the aperture area should measure at least 175 cm2 for wood-burning stoves.
An overly large chimney aperture will mean that too much energy will be required to heat
the chimney suciently to achieve an acceptable draught. If you have a brick chimney with
a large aperture, we recommend that you install an insulating chimney liner of the proper
diameter. This will increase the draught, and improve the fuel economy.
There are no requirements with respect to specic chimney heights, but a chimney must be tall
enough to provide a good draught, and to ensure that the smoke does not cause any problems.
As a general rule, there will be a satisfactory draught if the chimney extends 4 metres above the
stove and at least 100 cm above the spine of the roof. If the chimney is located along the side of
the house, the top of the chimney should never be lower than the spine of the roof or the high-
est point on the roof. Please note that there are often national and local regulations regulating
the location of chimneys in houses with thatched roofs. Please see section 1.9 Draught.
The chimney and the ue pipe must be tted with cleaning doors, which must be at least
the same size as the chimney’s aperture area.
The chimney must be accessible for external inspection, and it must be possible to access
the cleaning doors and the chimney if it is to be cleaned from the top (e.g. steel chimneys).
1.6 Connecting the ue pipe
Lift the upper cast iron top plate o the stove.
Note: The included round cast iron cover plate must be mounted on the upper cast iron top
plate if the stove is being installed with the ue pipe to the rear.
Mounting the ue collar pointing upwards
From the factory, the stove is prepared for installation with the included ue collar (1) pointing
upwards with included ball stop and screws. The ball stop, which prevents the chimney sweep
from damaging the stove’s bae plates while sweeping, is the 145 mm long rod that is provided.
Mounting the ue collar to the rear
If the stove is being installed with the
ue pipe to the rear, the round plate
fixed with two screws on the back
of the stove is dismounted. The iron
piece on the inside convection back
panel is knocked out with light, rm
taps with a hammer next to the small
”bridges” holding the piece.
The cast iron cover is removed from
the back panel and mounted on the
top plate. The ue collar is centred and
screwed onto the back of the stove
with the clamps and screws provided.
The ball stop is not used when install-
ing the ue collar to the rear.
The location of the baes
The baes (2) and (3), which are made
from vermiculite, are mounted at the
factory.
Make sure that the baes are correct-
ly assembled before lighting the stove
(please see the sketch).
13

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Morso 6140 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Morso 6140 in de taal/talen: Engels, Deens als bijlage per email.

De handleiding is 0,42 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Morso 6140

Morso 6140 Gebruiksaanwijzing en installatiehandleiding - Nederlands - 36 pagina's

Morso 6140 Gebruiksaanwijzing en installatiehandleiding - Deutsch - 20 pagina's

Morso 6140 Gebruiksaanwijzing en installatiehandleiding - Français - 36 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info