744508
12
Verklein
Vergroot
Pagina terug
1/19
Pagina verder
22
23
DK ENG
1.0 Installing your Morsø stove
1.1 Unpacking the stove
When shipped, the basic stove is ready for mounting legs or a base. The Morsø 4400
Series stoves weigh from 85 to 98 kg (188 to 216 pounds). In order to avoid damages, it is
recommended that two persons unpack and install the stove.
The stove can be delivered with dierent leg options. If the stove is placed on a combustible
oor the minimum leg length must be 200 mm.
1.2 Installing the stove
When shipped, the stove is prepared for installation with a top ue exit. The cast-iron ue collar
and the ball stop, which stops the chimney sweeper’s ball when sweeping, are included with the
stove and are installed when the chimney pipe is installed.
National and local regulations regarding the installation of wood-burning stoves must be observed,
as must local regulations regarding chimney connections and chimney installation. You may want to
ask your chimney sweep for advice. However, you, your technical adviser or workman are responsi-
ble for complying with the applicable national and local regulations.
1.3 Chimney sweep
As stated, it may be wise to consult your local chimney sweep before installing the stove. In
any event, the chimney sweep must be notied once the wood-burning stove has been in-
stalled. The chimney sweep will inspect the installation and schedule sweeping intervals with
you. If your chimney has not been used for some time, it should be inspected for cracks, bird
nests, etc., before it is used.
1.4 Location of the stove/distance requirements
Distance requirements apply only if the stove is placed near ammable materials. Your new
stove can be positioned as specied on the certicate of approval on the back of the stove
if the walls are made of ammable material.
Minimum distances from ammable material:
Type of stove Behind the stove (A)
To the sides of the
stove (B)
To furniture
Morsø 4400
uninsulated ue
pipe
300 mm 450 mm 1100 mm
Morsø S4400
insulated ue pipe
200 mm 450 mm 1100 mm
B
A
Min. afstand til brandbar væg for Morsø S11
Revisions
Rev.
Sign.:
Title:
Drawing no.:
Dim. without indication of margin acc. to DS/ISO 2768-1 m
1:10
Afstand til hjørnevæg
Distance to Corner wall
Morsø S11-40
RSV
A4
Dimension Skecth
Date of print: 10-08-2011
U:\udv\Tegninger\Diverse\Afstand til brandbare vægge\Afstand til hjørnevæg.SLDASM
S-11-020 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date:
Side 1 of 4
2011.07.11
A
A
45°
Min. afstand til brandbar væg for Morsø S11-40
Revisions
Rev.
Sign.:
Title:
Drawing no.:
Dim. without indication of margin acc. to DS/ISO 2768-1 m
1:10
Afstand til hjørnevæg
Distance to Corner wall
Morsø S11-40
RSV
2011.07.11
A4
Dimension Skecth
Date of print: 10-08-2011
U:\udv\Tegninger\Diverse\Afstand til brandbare vægge\Afstand til hjørnevæg.SLDASM
S-11-020 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date:
Side 2 of 4
We recommend that the stove be installed at least 10-15 cm from masonry in order to allow
heat to circulate and to facilitate the cleaning of the inside and outside of the stove. A layer
of wallpaper on a brick wall is normally regarded as non-ammable material.
The oor
If the stove is installed on a ammable oor, national and local regulations must be observed
with regard to the size of the non-ammable underlying surface that must cover the oor be-
neath the stove.
The underlying surface must naturally be able to bear the weight of the stove and, if ap-
plicable, the steel chimney.
Distance to furniture
We recommend that the stove be installed 1100 mm from furniture, but consideration should
also be given to whether furniture, etc., will dry out as a result of its proximity to the stove.
The distance to ammable material in front of the stove is 1100 mm.
A wood-burning stove gets hot when it is red. Caution must therefore be observed, par-
ticularly with regard to children touching the stove.
1.5 The chimney
If local regulations permit, the stove may be connected to a chimney already serving anoth-
er replace (such as an oil-burning stove or another wood-burning stove). Attention should
be paid to any requirements concerning the location of ue pipes if two or more replaces
are connected to the same chimney.
The wood-burning stove must never be connected to a chimney to which a gas-burning stove
is already connected. An ecient, modern stove places great demands on the chimney, so have
a chimney sweep check the condition of your chimney.
The aperture of the chimney must comply with national and local regulations. In general,
the aperture area should measure at least 175 cm2 (150 mm diameter) for wood-burning
stoves. Exceptions to this are: Smoke Exempt Morsø stoves tted with a 125mm diameter
ue collar. These can be connected to a chimney system or liner with a minimal cross sec-
tional area of 123 cm² (125mm diameter)
An overly large chimney aperture will mean that too much energy will be required to heat
the chimney suciently to achieve an acceptable draught. If you have a brick chimney with
a large aperture, we recommend that you install an insulating chimney liner of the proper
diameter. This will increase the draught, and improve the fuel economy.
There are no requirements with respect to specic chimney heights, but a chimney must be
tall enough to provide a good draught, and to ensure that the smoke does not cause any prob-
lems. As a general rule, there will be a satisfactory draught if the chimney extends 4 metres
above the stove and at least 80 cm above the spine of the roof. If the chimney is located along
the side of the house, the top of the chimney should never be lower than the spine of the roof
or the highest point on the roof. Please note that there are often national and local regula-
tions regulating the location of chimneys in houses with thatched roofs. Please see section
1.9 Draught.
The chimney and the ue pipe must be tted with cleaning doors, which must be at least
the same size as the chimney’s aperture area.
The chimney must be accessible for external inspection, and it must be possible to access
the cleaning doors and the chimney if it is to be cleaned from the top (e.g. steel chimneys).
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Morso 4441 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Morso 4441 in de taal/talen: Engels, Deens als bijlage per email.

De handleiding is 0,63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info