12
UK Helpline 0844 871 0960 Replacement Parts 0844 873 0726 Ireland Helpline 1800 409 119
De-scaling
The De-scaling Icon Ú will flash to indicate that
you need to perform the descaling process by
using citric acid.
Important:
Dissolve 2 tablespoons (about 30gram) of citric
acid in one litre of water.
1. Disconnect the appliance from the mains supply.
2. Make sure the appliance has cooled down
completely.
3. Remove the water tank ⁄ and drip tray ‡&·
from the coffee machine.
4. Place the appliance upside down and remove
the percolation grid* from the Brewing Head ›
by unscrewing the grid rivet with a philips head
screwdriver. P
5. Clean the percolation grid* and Brewing Head to
remove any scale or coffee residue.
6. Return the appliance to the normal upright
position.
7. Fill the water tank ⁄ with the dissolved citric
acid solution up to the MAX level marked on the
side of the tank.
8. Close the lid of water tank and refit the water
tank and Drip Tray to the machine.
9. Place an empty container under the Brewing
Head › to gather the de-scaled hot boiled
water.
10. Connect the appliance to a mains outlet; the
appliance will switch on and the Standby button
light will glow.
11. Press the Standby button Û.
12. The Standby Indicator È will rotate to indicate
that your coffee machine is heating up.
13. The Standby Indicator È will stop rotating with
a beep sound when your coffee machine
reaches the appropriate heat.
14. Press and hold the Coffee Quantity Selection ı
and Steam & Hot Water Buttons ˜ for 2 sec. Q
15. The Descaling Icon Ú will stop flashing.
16. The Standby Indicator will start rotating to show
that the De-scaling process is operating.
17. The de-scaled hot boiled water will come out
from the Brewing Head ›.
18. Wait until the citric acid solution stops brewing.
19. Remove & clean the water tank with clean fresh
water.
20. For the cleaning process, refill the water tank
with clean water up to the Max level marked on
the side of water tank.
21. Place an empty container under the Brewing
Head › to gather the hot boiled water.
22. Close the lid of the water tank ⁄
and refit the
water tank to the appliance.
23. The hot boiled water will automatically come out
from the Brewing Head ›.
24. After the whole de-scaling process completes,
the hot boiled water brewing will stop and the
appliance will switch off automatically.
25. The Power Standby button light will glow Û and
the Power Standby Icon Ì will display on the
LCD Screen.
26. Disconnect the appliance from mains supply.
27. Wait until the appliance has cooled down
completely
28. Remove the water tank and Drip Tray from the
coffee machine.
29. Put the appliance upside down and reinstall the
percolation grid* onto the Brewing Head › by
screwing in the grid rivet, for this refitting
process use a philips head screwdriver. R
*
The peculation grid is situated within the
Brewing Head. It is only visible or accessible for
cleaning during the descaling process.
Q
P