14
5.4 EXIT DELAY TIME
The exit delay time defines the time between the moment of switching on
the module and the moment the module is able to send the first alarm
message. The time can be set between 0 and 999 seconds. As default, the
exit delay time is set to 30 seconds.
5.5 SENSITIVITY
The sensitivity of the sensor is adjustable. With the high sensitivity, every
detection will be reported immediately. This setting is preferred. With the
low sensitivity, the detector reacts slightly less sensitively. This position
prevents false alarms caused by drafts, for example.
5.6 INACTIVE TIME
The “inactive time” defines the time the PIR senor (or extra input) is not
active after an activation. During the inactive time, no new alarm message
will be sent. The time can be set between 0 and 60 minutes. As default, the
inactive time is set to “5” for the PIR sensor (“0” for the extra inputs).
5.7 AUTOMATIC ARMING / DISARMING
The Mobeye MiniPir only works if the unit is armed, which is done via the
on/off button. It is possible to automatically arm and disarm the unit, based
on an arming and/or disarming time scheme. Two schemes can be entered,
which can be assigned to the days in the week (e.g. to have a different
weekend scheme).
As default the automatic (dis) arming times are valid for all days. It is
possible to assign them to only a few days in the week. In this way it is
possible to have two different schemes, which are valid on different days.
As value the weekdays can be entered. Monday is 1, Tuesday is 2, etc. If the
scheme is valid for several days, the days can be set in a row (e.g. 12345
means Monday till Friday).
Example: to arm the system only during weekdays, from 6AM to 7PM, set
the TIMEARM1 to 06:00, TIMEDISARM1 to 19:00 and DAYS1 to 12345.