9
Mobeye adapter 10027 position
- V+ to “+” black lead with white stripe left
- Ground to “-“ black lead 2nd from left
3.5 CONNECT A SENSOR TO THE INPUT (OPTIONALLY)
Two external sensors can be connected to the
inputs.
Insert the 2 wires of an external sensor through
the hole in the casing and insert them in the two
connectors of input 1 (press on the green pins for
connecting the wires). It does not matter which
wire is connected to which connector.
A second sensor may be connected to input 2.
As default the input is programmed as Normally Open (NO) contact. This
means the input is triggered if the input is closed for at least 1 second. In
case the contact is Normally Closed (NC), see paragraph 5.8. If the sensor
needs to be activated for a longer period before triggering an alarm, see 5.8.
3.6 NETWORK CONNECTION AND PROGRAM MODE
After placing the batteries (and external power) the Mobeye ThermoGuard
will search for the network. The outside LED flashes green and red. This
process normally takes 10-30 seconds, in a new device this can take some
minutes. When the network has been established the LED will first blink
green rapidly and next stay green (or flashes 1 sec. on/1 sec. off in case the
unit has not been configured yet).
In a battery-operated unit a time-out occurs after 3 minutes, after which the
communication module switches off in order to save the batteries. In this low
power mode the LED flashes once per 3 seconds. It will
search for network connection once it needs to send
notifications. It can also been forced to establish a network
connection by re-inserting the batteries or pressing the
button at the back for 5 seconds.
If the ThermoGuard is connected to an external power supply, it has
continuous network connection and is permanently in program mode.