24
7.2 HOW TO ACTIVATE THE CM-GUARD
After the previous steps the Mobeye CM-Guard is ready for use. It is armed
automatically.
In order to switch off (disarm) the Mobeye CM-Guard:
- Press the button at the backside for 1 second. The
green LED switches off to indicate the disarmed
status.
In the disarmed status the Mobeye CM-Guard will
not send alarm notifications. The unit remains
active and is able to switch on time-controlled and
to send 'low battery voltage' messages.
In order to switch on (arm) the Mobeye CM-Guard:
- Press the button at the backside for 1 second. The green LED blinks once
every 3 seconds (battery-powered) or stays on continuously (in case of an
external power supply).
If powered externally (with network connection), switching can be done via
SMS commands:
SMS command to switch on: CODE ARM (e.g. 1111 ARM)
SMS command to switch off: CODE DISARM (e.g. 1111 DISARM)
7.3 SYSTEM RESET
To reset the Mobeye CM-Guard to its factory settings:
1. Remove the batteries and SIM card (and external power supply).
2. Press the outside button while reinserting the batteries. Keep it pressed
for (about) another 5 seconds.
3. Release the button immediately after the LED starts to flash.
After a successful reset, the status LED will blink green to indicate that the
module is not configured. The security code is back to factory settings as
well.