Primary current protection
Secondary current protection
High-pressure protection
Defrosting in cooling
3 times Lighting Discharge temperature
protection
• Check refrigerant circuit and refrigerant amount.
• Refer to 10-6.G "Check of LEV".
• Refer to 10-6.B "Check of outdoor thermistors".
4 times Lighting Low discharge
temperature protection • Refer to 10-6.G "Check of LEV".
• Check refrigerant circuit and refrigerant amount.
5 times Lighting Cooling high-pressure
protection
This symptom does not mean any abnormality of the
product, but check the following points.
• Check if indoor filters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air circulation is short cycled.
-
-
These symptoms do not mean any abnormality of the
product, but check the following points.
• Check if indoor filters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air circulation is short cycled.
Twice Lighting
Once Lighting
When the discharge temperature exceeds 100: during operation.
When the frequency of the compressor is kept 80Hz or more and
the discharge temperature is kept under 39: for more than 20
minutes.
When the outdoor heat exchanger temperature exceeds 58:
during operation.
9 times Lighting Inverter check mode
Lighting Lighting Normal
When the unit is operated with emergency operation switch.
-
When the input current exceeds 15A.
When the current of the compressor exceeds 15A.
When the indoor gas pipe temperature exceeds 45: during heating.
When the indoor gas pipe temperature falls 3: or below during cooling.