587209
15
Verklein
Vergroot
Pagina terug
1/22
Pagina verder
14
ON – TIMER OPERATION
< WIRELESS REMOTE
CONTROL >
1 Press ON timer button.
ON timer display blinks.
2 Press or button to adjust to AM 8:00.
Displayed time will be changed by 10 minutes by pressing the buttons.
3 Press ON timer button.
ON timer display changes from blinking to steady lighting and
the setting is completed.
(Press within 60 seconds)
TIMER/CHECK display lamp of the air conditioner is lit. (The receiving part of
indoor unit)
At AM 8:00, TIMER/CHECK display lamp turns off and the air conditioner
will start operating.
1·3
2
Operation is started at the setting time.
In case the ON timer is set while the air
conditioner is in operation, it will be stopped
and ready for restart at the setting time.
[EXAMPLE] If you would like to start the operation at AM 8:00
Cancellation
Press CANCEL button to turn off the PROGRAM timer
display and timer is canceled. (Operation condition is kept as
before the button is pressed.)
If ON/OFF button is pressed during TIMER operation,
TIMER display turns off and the TIMER is canceled. The air
conditioner stops operating.
Changing the set time
Press OFF TIMER button or ON timer button to set again.
NOTICE
The same time cannot be set for OFF timer and ON timer.
PROGRAM TIMER OPERATION
By setting both ON timer and OFF timer, the settings turn into PROGRAM timer mode. Operation and stopping can be performed at the
same time of each day by setting program timer once.
1 Set ON timer.
Press ON timer button and set the time with
or
button.
Press ON timer button again.
2 Set OFF timer.
Press OFF timer button and set the time with
or
button.
Press OFF timer button again.
Both ON TIMER and OFF TIMER are displayed. The direction of arrow mark
changes depending on the status of operation.
(stop) (operating)
21
OFF
TIMER OPERATION
2·4
3
1
Operation is stopped at the setting time.
[EXAMPLE] If you would like to stop the operation at PM 9:00
Cancellation
Press CANCEL button to turn off the TIMER display and timer is canceled.
After TIMER setting, if ON/OFF button is pressed before the setting time, TIMER display turns off and the TIMER is canceled.
Time change
Press OFF TIMER button to set again.
Cancellation
Press CANCEL button to turn off the TIMER display and timer is canceled.
After TIMER setting, if ON/OFF button is pressed before the setting time,
TIMER display turns off and the TIMER is canceled.
Time change
Press ON TIMER button to set again.
HOW TO OPERATE
(Dehumidifying operation is prohibited for FDU-F.)
Turn on the power supply of both indoor/outdoor units for six hours before starting the unit to protect the units. (The
crankcase is conducted and the compressor is heated) Do not turn off the power supply. (The crankcase heater is conducted
while the compressor is stopped, preventing failure of the compressor due to accumulation of liquid refrigerant by keeping the
compressor warm.)
The operation of remote control must be performed slowly and steadily.
HOW TO USE < WIRELESS REMOTE CONTROL >
ATTENTION
4
1
5
3
2
AUTO
COOL
HEAT
DRY
FAN
Guideline of room temperature setting
COOL ...............26 to 28°C
DRY ..................21 to 24°C
HEAT ................22 to 24°C
FAN ................... TEMP setting is
unnecessary
Operation mode can be changed even
when the unit stops.
If you operate under the same condition
(operation mode, set temperature,
airflow, louver) just follow step 1, no
other operations are necessary. The
conditions which were set previously are
indicated on the remote control
CURRENT TIME SETTING PROCEDURE
1 Press TIME SET UP switch.
Press it with the tip of ballpoint etc. The time display blinks and can be set
to the current time.
2 Press or button to adjust to AM 8:00.
Morning : AM After noon : PM
The displayed time changes by 1 minutes when pressing the button.
If
or button is pressed during the blinking, fast-forward or
fast-backward can be done.
NOTICE
In case the buttons are not pressed for 60 seconds, the displayed time is set as
current time without step 3.
3 Press TIME SET UP switch.
The display changes from blinking to steady lighting and the setting is
completed.
1·3
2
The timer is set on the current time. Adjust the current time correctly at first of all.
[EXAMPLE] AM (morning) 8:00 setting
OPERATION
1 Press button.
The operation display light (Green) turns on, and the operation starts.
The setting status is displayed on the liquid crystal area on the remote
control.
2 Press MODE button.
Current operation mode is indicated with the marks besides the
operation mode icons.
The mode will change in the following order by pressing the button.
(AUTO)* COOL HEAT
FAN DRY
(The automatic operation can be selected in case of heat recovery system
KXR only. In case of KX, the automatic operation cannot be selected. In this
case, setting changes it to automatic operation.)
See page 13
3 Press TEMP button.
Set the room temperature by pressing or button.*
*
IN case of FDU-F
The setting temperature of the remote controller indicates the outdoor
temperature while operating thermostat ON/OFF.
4 Press FAN SPEED button.
HI
MED
LO
FAN SPEED can be changed in order.
5 Press AIR FLOW button.
Effective AIR FLOW direction see page 15
AUTO mode operation ............. Intermediate
Cooling, dehumidifying mode
... Horizontal
Heating mode .......................... Downwards
Stop
Press
button
Operation mode
1 Press ON/OFF button when the air conditioner stops.
The air conditioner starts to operate.
OFF timer can be set only in case the air conditioner is in operation.
2 Press OFF timer button.
OFF timer display blinks.
3 Press or button to adjust to PM 9:00.
Displayed time will be changed by 10 minutes by pressing the buttons.
4 Press OFF timer button.
OFF timer display changes from blinking to steady lighting and
the setting is completed. (Press within 60 seconds)
TIMER/CHECK display lamp of the air conditioner is lit. (The receiving part
of indoor unit)
At PM 9:00, TIMER/CHECK display lamp turns off and the air conditioner
will stops operating.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Mitsubishi FDUM bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Mitsubishi FDUM in de taal/talen: Engels als bijlage per email.

De handleiding is 10,87 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Mitsubishi FDUM

Mitsubishi FDUM Gebruiksaanwijzing - Nederlands - 22 pagina's

Mitsubishi FDUM Gebruiksaanwijzing - Deutsch - 22 pagina's

Mitsubishi FDUM Gebruiksaanwijzing - Français - 22 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info