566452
4
Verklein
Vergroot
Pagina terug
1/11
Pagina verder
PORTABLE AIR CONDITIONER
INSTRUCTION MANUAL
Read Rules for Safe Operation and Instructions Carefully.
CONTENTS
1.SAFETY RULES.............................................................................
2.NAMES OF PARTS..........................................................................
3.ACCESSORIES................................................................................
4.OPERATION PANEL OF THE AIR CONDITIONER........................
5.OPERATING INSTRUCTION FOR THE AIR CONDITIONER ........
6.INSTALLATION...............................................................................
7.MAINTENANCE...............................................................................
8.TROUBLE SHOOTING....................................................................
1
2
2
3
4
6
7
8
SAFETY RULES
1. DO NOT CONNECT UNIT TO ANY AC SOCKET IN DISREPAIR OR WITH
CONNECTIONS.
2. DO NOT USE IN THE FOLLOWING LOCATIONS:
- NEXT TO SOURCE OF FIRE.
- AN AREA WHERE OIL IS LIKELY TO SPLASH.
- AN AREA EXPOSED TO DIRECT SUNLIGHT.
- AN AREA WHERE WATER IS LIKELY TO SPLASH.
- NEAR A BATH, A SHOWER OR A SWIMMING POOL
- IN THE GREEN HOUSE
3. NEVER INSERT YOUR FINGERS OR ANY FOREIGN OBJECTS INTO THE AIR
OUTLET. TAKE SPECIAL CARE TO WARN CHILDREN OF THESE DANGERS.
4. ALWAYS STORE THE UNIT UPRIGHT IN ORDER TO MAINTAIN THE COMPRE-
SSOR IN A PROPER CONDITION.
5. BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
6. THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A SOCKET
OUTLET.
7. IF THE APPLIANCE IS COVERED, THERE IS A RISK OF OVERHEAT.
8. IF THE SUPPLY TOOL OF THIS APPLIANCE IS DAMAGED, IT MUST BE
REPLACED BY A REPAIR SHOP APPOINTED BY THE MANUFACTURER,
BECAUSE SPECIAL PURPOSE TOOLS ARE REQUIRED.
NOTE:
The air-conditioner can be connected only to a supply with system impedance no
more than 0.4582 ohm. But the system impedance should be at least 0.257ohm
(For 9000Btu/h models) or 0.208ohm(For 12000Btu/h models).
In case necessary, please consult your supply authority for system impedance
information.
1
If the supply cord(H05VV-F,3G1.0mm /220-240V~50Hz unit ,
or SJT,14AWG/3C/220-230V~60Hz unit) is damaged, it must
be replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
2
CAUTION
ACCESSORIES
PARTS :
PARTS NAME :
DUCT
ADAPTOR A (FOR PERMANENT DUCT
MOUNTING)
ADAPTOR B (FOR TEMPORARY DUCT
MOUNTING)
WALL PLUG
QUANTITY :
1
1
1
4
4
Check all the accessories are included in the package and please refer to the installation instructions
for their usage.
ALKALINE BATTERIES
2
1
1
REMOTE CONTROLLER
WATER PUMP DRAIN HOSE
SCREWS
2
NAMES OF PARTS
OPRATION PANEL
AIR OUTLET
REMOTE CONTROLLER
CASTER
REAR COVER
FRONT COVER
AIR INLET
OUTDOOR
WATER PUMP
DRAIN HOSE
POWER CORD
AIR INLET INDOOR
AIR OUTLET
OUTDOOR
AIR INLET
OUTDOOR
CONTINUOUS
DRAIN HOSE
FRONT VIEW
SIDE VIEW REAR VIEW
Fig.1
Fig.2
3
OPERATION PANEL OF THE AIR CONDITIONER(COOLING AND HEATING)
OPERATING PANEL
OPERATION PANEL OF THE AIR CONDITIONER(COOLING ONLY TYPE)
TEMP SETTING BUTTON
Select your desired room temperature
setting by pressing the button (up)
or button (down)
DIGITAL DISPLAY
INFRARED
SIGNAL RECEIVER
TIMER ON/OFF INDICATOR
TIMER ON/OFFBUTTON
Program the on/off timer function
COOL/DRY/FAN INDICATOR
Green lamp will light when the mode is selected
FAN SPEED INDICATOR
WATER FULL INDICATOR
Red lamp will blink when the tank is full
POW ER INDICATOR
POWER BUTTON
Turn on/off the unit
MODES BUTTON
Select the operation mode
from COOL.DRY.FAN.
FAN SPEED BUTTON
Press the button to select
the fan speed from
HIGH.MED or LOW
OPERATING PANEL
TEMP SETTING BUTTON
Press your desired room temperature
setting by pressing the button (up)
or button (down)
DIGITAL DISPLAY
TIMER ON/OFF INDICATOR
TIMER ON/OFF BUTTON
Program the on/off timer function
COOL/DRY/FAN/HEAT INDICATOR
Green lamp will light when the mode is selected
FAN SPEED INDICATOR
WATER FULL INDICATOR
Red lamp will blink when the tank is full
POWER INDICATOR
POWER BUTTON
Turn on/off the unit
MODES BUTTON
Select the operation mode
from COOL.DRY.FAN.HEAT
FAN SPEED BUTTON
Select the fan speed from
HIGH.MED or LOW
INFRARED
SIGNAL RECEIVER
Fig.4
Fig.3
Fig.5a
4
OPERATING INSTRUCTING FOR THE AIR CONDITIONER
Before Starting This Unit
1) Select a suitable location, make sure you have easy access to an electrical outlet.
2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.5 &
Fig.5a
Fig.5
1 BEFORE USE
Dehumidifying and Cooling Operations
OOOO
- The operating range for dehumidifying is 10 C-30 C/50 F-86 F, and the operating range for
OOOO
cooling operating is 17 C-30 C/63 F-86 F.
- If the cooling or dehumidifying operations have been switched off and need switching on again
in a short time, allow approximately three minutes for the cooling or dehumidifying operations
to resume.
- Make sure the water pump drain hose is correctly connected to the unit.
Power supply:
- Insert the AC Power Plug to a AC socket.
- Do not connect the air conditioner to a multiple socket outlet which is also being used for other
electrical appliance.
- Be sure the power supply is AC 220V-240V~ 50Hz/ or 220-230V~ 60Hz (Refer to the nameplate
located on the right side of the unit.) .
Water pump drain hose
Fig.6
NOTE: Step 2 is required only while using the cooling mode .
3) Plug the unit into a 220-240V~50Hz/ or 220-230V~ 60Hz (Refer to the nameplate located on
the right side of the unit.) grounded electrical outlet.
4) Make sure the water pump drain hose is correctly installed.
5) Press the on/off button to turn on the unit.
5
OOOO
2 COOLING OPERATION (Operating temperature range:
17 C-32 C/63 F-90 F
)
- Press the "MODE" button several times until the "COOL" indicator light comes on.
- Press the "TEMP SETTING" buttons "" or "" to select your desired room temperature.
OOOO
(17 C-30 C/63 F-86 F)
- Press the "FAN SPEED" button to choose the fan speed.
OOOO
3 DEHUMIDIFYING OPERATION (Operating temperature range:
13 C-32 C/55 F-90 F
)
- Press the "MODE" button several times until the "DRY" indicator light comes on. -
- The fan will run at a fixed speed at this setting.
- Keep windows and doors closed for the best dehumidifying effect.
- Do not put the duct to window.
4 HEATING OPERATION
(Cooling only type without heat feature)
OOOO
(Operating temperature range:5
C-30 C/41 F-86 F
)
- Press the "MODE" button several times until the "HEAT" indicator light comes on.
- Press the "TEMP SETTING" buttons "" or "" to select your desired room temperature.
OOOO
(17 C-30 C/63 F-86 F)
- Press the "FAN SPEED" button to choose the fan speed.
- Do not put the duct to window.
5 FAN OPERATION
- Press the "MODE" button several times until the "FAN " indicator light comes on.
- Press the "FAN SPEED" button to choose the fan speed.
- Do not put the duct to window.
6 TIMER OPERATION
Setting the on timer:
- Press the "TIMER ON" button when the air conditioner is off. Select the time you need the unit
start to operate.
- The Operation Paned Window will display "ON"
- The starting time is adjustable from 0.00 to 24.
Setting the off timer:
- Press the "TIMER OFF" button when the air conditioner is on. Select the time you need the unit
turn off. The Operation Panel Window will display "OFF".
- The turning off time is adjustable from 0.00 to 24.
7 WATER PUMP DRAINAGE
8 CONTINUOUS DRAINAGE
- Connect the water pump drain hose to the unit before operate. When the water level of the internal
water tank reaches a predetermined level, the water pump will be activated and drain the
condensed water outside through the connected drain hose. The maximum delivery lift is 3.5m.
(Under this condition, attach the rubber blockage to the back hole to prevent continuous drainage.)
- When you plan to leave this unit unused for a long time, remove the rubber blockage form the back
hole and attach a section of the continuous drain hose to drain hose connector. All the water in the
water tank would drain outside through the drain hose. (Under this condition, the water pump is not
activated.)
6
INSTALLATION
Install the mobile air conditioner in a flat and spacious location
where the air outlets will not be covered up. A minimum
clearance of 30cm from a wall or other obstacles should
be kept. The appliance shall not be used in the laundry.
The plug shall accessible after appliance is positioned.
Wiring shall be done according to National rules.
1 IMPORTANT:
2 DUCT MOUNT INSTRUCTIONS:
Exhaust Air Oulet
Duck
A) TEMPORARY-
1. Attach one end of the duct to the exhaust air outlet of the
mobile air condition, first fit the left side of the duct on the
exhaust air panel, then the right side duct. Push it
downwards, be sure to fix thoroughly. (See the figures)
2. Attach the other end of the duct to adaptor B.
3. Put the end of duct to a nearby window.
B) PERMANENT-
1. Attach one end of the duct to the exhaust air outlet of the
mobile air conditioner. According to the arrow direction,
first fit the left side of the duct on the exhaust air panel,
then the right side duct. Push it downwards, be sure to fix
thoroughly. (See the figures)
2. Install the adaptor A onto the wall by using 4 wall plug and
screws, be sure to fix thoroughly. (See the figures)
3. Attach the other end of the duct to adaptor A.
4. Cover the hole using the adaptor cap when not in use.
The duct can be compressed or extended between 500mm
and 2000mm, but it is desirable to keep the duct length to a
minimum.
IMPORTANT:
DO NOT OVER BEND THE DUCT (SEE FIGURE)
Adapter A
Rawlplugs
Skruer
max 120CM
min 30CM
Fig.8
Fig.9
Fig.10
30cm
30cm
Fig.7
7
Your window kit has been designed to fit most standard
Vertical and horizontal window applications, However, it
may be necessary for you to improvise/modify some aspects
of the installation procedures for certain types of window.
Please refer to Fig. 11 & Fig. 11a for minimum and maximum
window openings.
Window Kit Installation
Horizontal
window
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Horizontal
window
This unit is equipped with a internal water tank, two full-safe
switch mechanisms, one is used to control the water pump
drainage, the other is used to monitor the water level inside
the internal water tank. When the water level reaches a
predetermined level, the full-safe switch mechanism is
activated. The digital display shows P1 and the water full
indicator light illuminates. Carefully move the unit outside,
remove the rubber blockage from the back drainage hole
and drain the water off. The unit will continue operating
properly.
Drain Tank Safety Feature
MAINTENANCE
1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
2) DO NOT USE GASOLING, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT.
3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. THE ELECTRICAL
CAUE DANGER.
4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS
AGENCY.
IMPORTANT:
1 AIR FILTER
- Clean the air filter at least once every two weeks to
prevent inferior fan operation because of dust.
- Removal
Pull out the filter cover and remove the air filter from the
filter cover.
- Cleaning
Wash the air filter by immersing it gently in warm water
OO
(about 40 C/104 F) with a neutral detergent. Rinse the
filter and dry it in a shady place.
- Mounting
Attach the air filter to the filter cover using the attachment
hooks on the inner surface of the cover. Put the filter cover
back to the unit.
2 UNIT ENCLOSURE
- Use a lint-free cloth soaked with neutral detergent to clean
the unit enclosure. Finished by a dry clean cloth.
Fig.11
Fig.11a
Fig.12
8
TROUBLE SHOOTING
1. UNIT DOES NOT
START WHEN
PRESSING 1/0 BUTTON
- Water full indicator blinks, water tank
is full.
Dump the water in the water tank.
TROUBLES
POSSIBLE CAUSES
SUGGEST REMEDIES
Reset the temperature.
Reset the temperature.
Make sure all the windows and
doors are closed.
Remove the heat sources if possible.
Connect the duct and make
sure it can function properly.
Decrease the set temperature.
Clean the air filter.
- Room temperature is higher than
the set temperature.(Heating mode)
- Room temperature is lower than
the set temperature.(Cooling mode)
- The windows or doors in the room
are not closed.
- There are heat sources inside the
room.
- Exhaust air duct is not connected or
blocked.
- Temperature setting is too high.
- Air filter is blocked by dust.
2. NOT COOL ENOUGH
Place the unit on a flat, level
ground if possible.
It is normal.
- The ground is not level or not flat
enough.
- The sound comes from the flowing
of the refrigerant inside the
air-conditioner.
4. NOISY OR VIBRATION
5. GURGLING SOUND
Switch on again after the unit has cool down.
- The automatic over heat protection
function. When the temperature at
OO
the air outlet exceed 70 C/158 F,the
device will
st
o
p.
3. POWER SHUT OFF AT
HEATING MODE
CS260-U
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Midea mpf14cen2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Midea mpf14cen2 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,07 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info