588085
5
Verklein
Vergroot
Pagina terug
1/10
Pagina verder
3
owners manual
3. AIR CONDITIONER OPERATIONS AND
PERFORMANCE
Use the system in the following temperature for safe and
effective operation. The Max operation temperature for
the air conditioner (Cooling/Heating).
1
If air conditioner is used outside the above conditions, it
may cause the unit to function abnormally.
The phenomenon is normal that the surface of air
conditioning may condense water when the relative
larger humidity in room, please close the door and
window.
Table 3-1
NOTE
Cooling operation
Dry operation
Heating operation
(cooling only type without)
Mode
Temperature
Outdoor
temperature
(for the models with low
temperature cooling system)
temperature
0°C ~ 50°C / 32 °F~122°F
0°C ~ 50°C / 32 °F~122°F
-15°C ~ 50°C / 5 °F~122°F
-15°C ~ 24°C / 5 °F~76°F
0°C ~ 30°C / 32 °F~86°F
17°C ~ 32°C
( 62 °F ~ 90°F)
17°C ~ 32°C
( 62 °F ~ 90°F)
Optimum performance will be achieved within these
operating temperature range.
2
3
4. HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical
operation.
Adjust the air flow louver properly and avoid direct air flow to
room inhabitants.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Prevent direct sunlight during cooling operation by using
curtains or blinds.
Ventilate often. Extended use requires special attention to
ventilation.
Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease
in the cooling or heating effect.
Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.
Set the timer .
If you don't plan to use the unit for a long time, please take the
batteries from the remote controller. When the power is on,
some energy will be consumed,even if the air conditioner isn't in
operation. So please disconnect the power to save energy.
Keep the indoor unit and remote controller at least 1 m away
from televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.
A dirty air filter will reduce cooling or heating efficiency, please
clean it once two weeks.
5. ADJUSTING AIR FLOW DIRECTION
While the unit is in operation, you can adjust the air flow louver
to change the flow direction and naturalize the room
temperature evenly. Thus you can enjoy it more comfortably.
Set the air flow direction.
Press the SWING button to adjust the louver to the desired
position and press this button again to maintain the louver at
this position.
Adjust the air flow direction automatically.
Press the SWING button, the louver will swing automatically.
While this function is set, the swing fan of indoor unit runs;
otherwise, the swing fan doesn't run. The swing scale of every
side is 30°. When the air conditioner isn't in operation (including
when TIMER ON is set), the SWING button will be invalid.
Adjust it up and down
Fig 5-1
Fig 5-2
Adjust it up and down
Three-minute protection feature
A protection feature prevents the air conditioner from being
activated for approximately 3 minutes
when it restarts immediately after operation.
Auto-restart function
Power failure during operation will stop the unit completely.
When the power restores, the OPERATION indicator on the
indoor unit starts flashing.For the unit without Auto-restart
feature, to restart the operation, push the ON/OFF button
on the remote controller. For the unit with Auto-restart
feature, the unit restarts automatically with all the previous
settings preserved by the memory function.
Refrigerant Leakage Detection(optional):
With this new technology, the dipsplay area will appear EC (if
applicable) and the LED indication lamps continue flashing
when the outdoor unit detects refrigerant leakage.
Louver Angle Memory Function(optional):
For some models, the machine is special designed with louver
angle memory function.Power failure during operation or
pressing the ON/OFF button on the remote controller will stop
the unit completely.When the power restores or pressing the
ON/OFF button on the remote controller again,the unit restarts
automatically with the previous open angle of the horizontal
louver by the memory function.So we strongly recommend that
the open angle of the horizontal louver should not be set too
small,in case the condensed water forms and drops from the
horizontal louver. Press the Manual control button and the open
angle of the horizontal louver will be restored to the standard
angle.
,
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Midea Super Slim Cassette bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Midea Super Slim Cassette in de taal/talen: Engels als bijlage per email.

De handleiding is 1,51 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info