owners manual
Use the system in the following temperature for safe and
effective operation.The Max operation temperature for
the air conditioner.(Cooling/Heating)
3. AIR CONDITIONER OPERATIONS AND
PERFORMANCE
1
If air conditioner is used outside the above conditions, it may
cause the unit to function abnormally.
Room relative humidity should be less than 80%. If the air
conditioner is over it , the surface of the air conditioner may
condense water . Please set the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH speed.
Optimum performance will be achieved within these
operating temperature range.
2
3
Fig. 5-1
Fig. 5-2 Fig. 5-3
4. HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical operation.
(Refer to corresponding chapterfor details)
5. ADJUSTING AIR FLOW DIRECTION
Auto-swing
Press SWING button, the louver will swing up and down
automatically.
When cooling
Adjust the louver downwards. (horizontally)(Refer to Fig.5-2).
When heating
Adjust the louver vertically(Refer to Fig.5-3)
Three-minute protection feature
A protection feature prevents the air conditioner from being
activated for approximately 3 minutes when it restarts immedi-
ately after operation.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start
flashing when power is restored
To restart operation, push the ON/OFF button on the
remote controller.
Lightning or a car wireless telephone operating nearby
may cause the unit to malfunction.
Disconnect the unit with the power and then connect the unit
with the power again. Push the ON/OFF button on the remote
controller to restart operation.
Adjust the air flow direction properly to avoid winding toward
your body.
Adjust the room temperature properly to get a comfortable
situation and to avoid supercooling and superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or
windows more often than necessary.
Set the timer for the desired operating time.
Never put obstructions near the air outlet or the air inlet. Or it
will cause lower efficiency, even a sudden stop.
If you don't plan to use the unit for a long time, please discon-
nect power and remove the batteries from the remote control-
ler. When the power switch is connected, some energy will be
consumed, even if the air conditioner isn't in operation. So
please disconnect the power to save energy. And please
switch the power on 12 hours before you restart the unit to
ensure a smooth operation.
A clogged air filter will reduce cooling or heating efficiency,
please clean it once two weeks.
Manual Swing
Press Air Direction button,the louver can be fixed at a desir-
ed angle.The louber swing (upward or downward ) to a
certain angle for each press.
CAUTION
Table 3-1
0°C ~ 30°C / 32 °F~86°F
17°C ~ 32°C
( 62 °F ~ 90°F)
17°C ~ 32°C
( 62 °F ~ 90°F)
Cooling operation
Drying operation
Heating operation
(cooling only type without)
Mode
Temperature
Outdoor
temperature
(for the models with low
temperature cooling system)
temperature
0°C ~ 50°C / 32 °F~122°F
0°C ~ 50°C / 32 °F~122°F
-15°C ~ 50°C / 5 °F~122°F
-15°C ~ 24°C / 5 °F~76°F
With this new technology, the dipsplay area will appear EC (if
applicable) and the LED indication lamps continue flashing
when the outdoor unit detects refrigerant leakage.
Louver Angle Memory Function(optional):
For some models, the machine is special designed with louver
angle memory function.Power failure during operation or
pressing the ON/OFF button on the remote controller will stop
the unit completely.When the power restores or pressing the
ON/OFF button on the remote controller again,the unit restarts
automatically with the previous open angle of the horizontal
louver by the memory function.So we strongly recommend that
the open angle of the horizontal louver should not be set too
small,in case the condensed water forms and drops from the
horizontal louver. Press the Manual control button and the open
angle of the horizontal louver will be restored to the standard
angle.
Refrigerant Leakage Detection(optional):
,
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Midea MFAD-Serie bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Midea MFAD-Serie in de taal/talen: Engels als bijlage per email.

De handleiding is 1,87 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Midea MFAD-Serie

Midea MFAD-Serie Installatiehandleiding - Deutsch - 16 pagina's

Midea MFAD-Serie Gebruiksaanwijzing - Deutsch - 12 pagina's

Midea MFAD-Serie Installatiehandleiding - English - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info