588158
5
Verklein
Vergroot
Pagina terug
1/22
Pagina verder
AIR CONDITIONER
Thank you very much for purchasing our air conditioner, please read this owner's
manual carefully before using your air conditioner.
,
OWNER S MANUAL
CONTENT
IMPORTANT SAFETY INFORMATION---------------------------------------------------------------------1
PARTS NAMES---------------------------------------------------------------------------------------------------2
ADJUSTING AIR FLOW DIRECTION-----------------------------------------------------------------------13
HINTS FOR ECONOMICAL OPERATION-----------------------------------------------------------------2
TEMPORARY OPERATIONS---------------------------------------------------------------------------------14
MAINTENANCE-------------------------------------------------------------------------------------------------14
AIR CONDITIONER OPERATIONS AND PERFORMANCE------------------------------------------16
INSTALLATION----------------------------------------------------------------------------------------------------17
TROUBLES AND CAUSES----------------------------------------------------------------------------------18
TROUBLES AND CAUSES(CONCERNING REMOTE CONTROLLER)-------------------------18
Danger
No
Household
Drain
Cleaner
IMPORTANT SAFETY INFORMATION
Do not attempt to install this unit by yourself. This unit requires
installation by qualified persons.
Do not use caustic household drain cleaners in the unit. Drain
cleaners can quickly destroy the unit components (drain pan and
heat exchanger coil etc).
CAUTION
CAUTION
NOTE
DANGER
DANGER
WARNING
WARNING
WARNING
Do not attempt to service the unit yourself. This unit has no user
serviceable components. Opening or removing the cover will
expose you to dangerous voltage. Tuning off the power supply will
not prevent potential electric shock.
To avoid the risk of serious electrical shock, Never sprinkle or
spill water or liquids on unit.
Ventilate the room regularly while the air conditioner is in use,
especially if there is also a gas appliance in use in this room,
Failure to follow these directions may result in a loss of oxygen
in the room.
To prevent electric shock, turn off the power or disconnect the
power supply plug before beginning any cleaning or other routine
maintenance. Follow the directions for cleaning in the Owner's
Manual.
1
!!
!!
!!
!!
!!
!!
!!
!!
!!
No
Thinner
DANGER
Never put hands or objects into the Air Outlet of indoor or outdoor
units. These units are installed with a fan running at high speed.
To touch the moving fan will cause serious injury.
Do not use liquid cleaners or aerosol cleaners, use a soft and dry
cloth for cleaning the unit. To avoid electric shock, never attempt
to clean the units by sprinkling water.
For proper performance, operate the unit in temperature and
humidity ranges indicated in this owner's manual. If the unit is
operated beyond these conditions, it may cause malfunctions
of the unit or dew dripping from the unit.
HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical operation. (Refer to corresponding chapter
for details)
Adjust the air flow direction properly to avoid winding toward your body.
Adjust the room temperature properly to get a comfortable situation and to avoid supercooling and
superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or windows more often than necessary.
Set the timer for the desired operating time.
Never put obstructions near the air outlet or the air inlet. Or it will cause lower efficiency, even a
sudden stop.
If you don't plan to use the unit for a long time, please disconnect power and remove the batteries
from the remote controller. When the power switch is connected, some energy will be consumed,
even if the air conditioner isn't in operation. So please disconnect the power to save energy. And
please switch the power on 12 hours before you restart the unit to ensure a smooth operation.
A clogged air filter will reduce cooling or heating efficiency, please clean it once two weeks.
PARTS NAMES
f
b
d
e
i
m
n
l
p
o
c
CC
q
a
j
k
e
g
d
e
Display Panel
The air conditioner consists of the indoor unit, the outdoor unit, the connecting pipe and the remote
controller.
Cassette Type
NOTICE!
This chart is based on 24000Btu/h type. So, a few differences may exist on the outlook and functions
from yours.
2
a) indoor unit b) outdoor unit
c) remote controller d) air-in
e) air-out f ) air outlet
g) air flow louver (at air outlet) h) connecting pipe
i ) drain hose j ) air inlet (with air filter in it)
k) drain pump (drain water from indoor unit) l ) infrared signal receiver
m) temporary button n) operation lamp
o) timer indicator
p) PRE-DEF indicator (cooling and heating type) or fan only indicator (cooling only type)
q) alarm indicator
NAMES AND FUNCTIONS
NAMES AND FUNCTIONS
h
b
d
e
i
m
n
l
p
o
b
c
f
a
d
e
g
h
i
j
k
m
o
p
l
n
c
C
k
f
d
j
a
k
g
Display Panel
High-static Pressure Parvis Split Type
NOTICE!
This chart is based on 24000Btu/h type. So, a little differences may exist on the outlook and functions
from yours.
indoor unit
air-inlet
heat exchanger
outdoor unit
air-out
connecting pipe
E-Box
remote controller
air outlet
drain hose
infrared signal receiver
operation lamp
timer indicator
temporary button
PRE-DEF indicator
(cooling and heating type) or fan only indicator (cooling
alarm indicator
only type)
3
Duct and Ceiling Type
h
b
f
d
d
e
i
m
n
l
p
o
c
CC
j
a
g
k
NOTICE!
This chart is based on 24000Btu/h type. So, a few differences may exist on the outlook and
functions from yours.
a) indoor unit b) outdoor unit
c) remote controller d) air-in
e) air-out f ) air outlet
g) air flow louver (at air outlet) h) connecting pipe
i ) drain hose j ) air inlet (with air filter in it)
k) infrared signal receiver l ) manual button
m) operation lamp n) timer indicator
o) PRE-DEF indicator p) alarm indicator
(NOTICE: In the case of "cooling only type", it is the "FAN ONLY" indicator.)
NAMES AND FUNCTIONS
4
d
i
m
n
l
o
c
ÎÂ
¶È
ÎÂ
¶È
ʱ
ÖÓ
ʱ
ÖÓ
·ç
ËÙ
·ç
ËÙ
Ä£
ʽģ
ʽ
·çËÙ·çËÙ
¿ª¿ª
¹Ø¹Ø
ÎÂ
¶È
ÎÂ
¶È
×Ô
¶¯
×Ô
¶¯
C
C
a
Display Panel
h
g
k
j
b
d
NAMES AND FUNCTIONS
b
c
f
a
d
e
g
h
i
k
m
o
l
n
NOTICE!
indoor unit
air-in
drain hose
outdoor unit
air flow louver (at air outlet)
remote controller
connecting pipe
infrared
signal receiver
operation lamp
timer
indicator
temporary
button
Alarm Indicator
j
FAN/DEF indicator
,,
(For cooling and heating type, its D EF.,for cooling only type, its F AN)
Air-out
The chart based on one model of our product is for reference only, which may be different from
the unit you purchased.
5
For Slim Duct Type
e
f
E-Box
NOTICE!
This chart is based on 24000Btu/h. type. So, a few differences may exist on the outlook and functions from yours.
For Slim Duct Type
f
b
d
e
i
m
n
l
p
o
c
ÎÂ
¶È
ÎÂ
¶È
ʱ
ÖÓ
ʱ
ÖÓ
·ç
ËÙ
·ç
ËÙ
Ä£
ʽģ
ʽ
·çËÙ·çËÙ
¿ª¿ª
¹Ø¹Ø
ÎÂ
¶È
ÎÂ
¶È
×Ô
¶¯
×Ô
¶¯
C
C
a
Display Panel
h
g
k
j
NAMES AND FUNCTIONS
b
c
f
a
d
e
g
h
i
j
k
m
o
p
l
n
indoor unit
air-out
outdoor unit
air-inlet
connecting pipe
E-Box
remote controller
air- outlet
drain hose
infrared signal receiver
operation lamp
timer indicator
temporary button
PRE./DEF. indicator
(cooling and heating type) or fan only indicator (cooling
alarm indicator
only type)
6
NAMES AND FUNCTIONS
h
b
d
e
i
m
n
l
p
o
b
c
f
a
d
e
g
h
i
j
k
m
o
p
l
n
c
ÎÂ
¶È
ʱ
ÖÓ
·çËÙ
Ä£
ʽ
·ç
ËÙ
¿ª
¹Ø
ÎÂ
¶È
×Ô
¶¯
C
k
f
d
j
a
f
g
Display Panel
indoor unit
air-out
heat exchanger
outdoor unit
air-outlet
connecting pipe
E-Box
remote Controller
air- inlet
drain hose
infrared signal receiver
operation lamp
timer indicator
temporary button
PRE./DEF. Indicator
(Cooling and heating type) or fan only indicator (cooling
alarm indicator
only type)
For Slim DUCT with air inlet box Type
7
This picture is based on the type of 18000Btu/h, So the appearance and function may be
different from the unit you purchased.slightly
12 13
14
15
2
6
7
4
3
8
5
1
9
11
10
Indoor Unit Assy
Outdoor Unit Assy
Control board
Inlet
Outlet
Manual
OPERATION
TIMER
DEF./FAN.
ALARM
Indoor Unit
Air outlet
Drain hose
Drain Pump (Internal installed),water drain from indoor unit.
Infrared Signal receiver
Timer indicator
Alarm indicator
Defrost indicator
heating/cooling type or fan indicator (cooling
only type)
Outdoor Unit
Vertical louver
Manual button
Remote Controller
Connecting pipe
Run lamp
1
7
10
4
9
13
15
2
3
Parts Names:
11 12
14
8
5
6
Air Inlet (Air filter installed inside to prevent the dust)
Four-way Cassette(slim) Type
8
OUTDOOR UNIT
Display panel
INDOOR UNIT
Outlet louver
Inlet
Filter
Display panel
Remote controller
Refrigerant connecting, drain
hose pipe
Electric wiring
Trap
Air outlet
Air inlet(side and rear)
MANUAL
RUN
FAN
TIMER
ALARM
inlet
TEMP
CLOCK
SPEED
C
MODE
FAN
I
O
TEMP
inlet
outlet
MANUAL
RUN
TIMER
DEF
ALARM
MANUAL
RUN
TIMER
FAN
ALARM
MANUAL button
Run lamp
FAN indicator(Cooling/Heating
type without)
TIMER indicator
ALARM indicator
DEF. indicator(Cooling-only type
without)
16
INDOOR UNIT
DISPLAY PANEL
OUTDOOR UNIT
16
One-way Cassette Type
9
Cooling-only typeCooling&Heating type
f
c
CC
g
Display Panel
Ceiling & Floor Type(for )VERTICAL DISCHARGE AIR CONDITIONER
10
NAMES AND FUNCTIONS
b
c
f
a
d
e
g
h
i
k
m
o
l
n
NOTICE!
indoor unit
air-in
drain hose
outdoor unit
air flow louver (at air outlet)
air inlet (with air filter in it)
installation part
remote controller
connecting pipe
infrared signal receiver
operation lamp
timer indicator
temporary button
alarm
indicator
j
FAN/DEF indicator
,,
(For cooling and heating type, its D EF.,for cooling only type, its F AN)
P
air-out
The chart based on one model of our product is for reference only, which may be different from
the unit you purchased.
b
d
p
n
m
o
l
k
J
i
a
e
d
h
p
f
c
CC
g
Display Panel
NAMES AND FUNCTIONS
b
c
f
a
d
e
g
h
i
k
m
o
l
n
NOTICE!
indoor unit
air-in
drain hose
outdoor unit
air flow louver (at air outlet)
air inlet (with air filter in it)
installation part
remote controller
connecting pipe
infrared signal receiver
operation lamp
timer indicator
temporary button
alarm
indicator
j
FAN/DEF indicator
,,
(For cooling and heating type, its D EF.,for cooling only type, its F AN)
P
air-out
Ceiling & Floor Type
11
The chart based on one model of our product is for reference only, which may be different from
the unit you purchased.
n
m
o
l
k
J
i
a
e
d
h
p
b
d
p
f
b
d
p
i
n
m
o
c
CC
l
a
j
k
g
e
d
Display Panel
h
p
NAMES AND FUNCTIONS
b
c
f
a
d
e
g
h
i
k
m
o
l
n
NOTICE!
indoor unit
air-in
drain hose
outdoor unit
air flow louver (at air outlet)
air inlet (with air filter in it)
installation part
remote controller
connecting pipe
infrared signal receiver
operation lamp
timer indicator
temporary button
alarm
indicator
j
FAN/DEF indicator
,,
(For cooling and heating type, its D EF.,for cooling only type, its F AN)
P
air-out
Ceiling & Floor Type
12
The chart based on one model of our product is for reference only, which may be different from
the unit you purchased.
ADJUSTING AIR FLOW DIRECTION
Cassette Type
While the unit is in operation, you can adjust the air flow louver to change the flow direction and natu-
ralize the room temperature evenly. Thus you can enjoy it more comfortably.
1. Set the desired air flow direction.
Push the SWING button to adjust the louver to the desired position and push this button again to
maintain the louver at this position.
2. Adjust the air flow direction automatically.
Push the SWING button, the louver will swing automatically.
While this function is set, the swing fan of indoor unit runs; otherwise, the swing fan doesn't run. The
0
swing scale of every side is 30 . When the air conditioner isn't in operation (including when "TIMER
ON" is set), the SWING button will be disabled.
The following is how to adjust air flow direction when air outlet part (separately saled) is
used with the indoor unit.
Heating
To effectively heat the bottom of the room,
Please set the louver so that the air can
come out downwards.
Duct and Ceiling Type
Cooling
To effectively cool the whole room, please
set the louver so that the air can come out
horizontally.
ADJUST IT UP AND DOWN
13
TEMPORARY OPERATIONS
MAINTENANCE
TEMPORARY
BUTTON
This function is used to operate the unit temporarily
in case you misplace the remote controller or its
batteries are exhausted. Two modes including AUTO
and mandatory COOL can be selected through the
TEMPORARY BUTTON on the air inlet grill control
box of the indoor unit. Once you push this button, the
air conditioner will run in such order: AUTO,
mandatory COOL, OFF, and back to AUTO.
1. AUTO
The OPERATION lamp is lit, and the air conditioner
will run under AUTO mode. The remote controller
operation is enabled to operate according to the
received signal.
2. mandatory COOL
The OPERATION lamp flashes, the air conditioner
will turn to AUTO after it is enforced to cool with a
wind speed of HIGH for 30 minutes. The remote
controller operation is disabled.
3. OFF
Note: Only take the cassette type as example.
The OPERATION lamp goes off. The air conditioner
is OFF while the remote controller operation is
enabled.
14
WARNING
Cleaning the indoor unit and remote controller
WARNING
Before you clean the air conditioner, be sure to disconnect the power supply plug.
If you do not plan to use the unit for at least 1 month.
(1) Operate the fan for about half a day to dry the inside of the unit.
(2) Stop the air conditioner and disconnect power.
(3) Remove the batteries from the remote controller.
!!
Use a dry cloth to wipe the indoor unit and remote controller.
A cloth dampened with cold water may be used on the indoor unit if it is very dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically-treted duster for wiping or leave such material on the unit for long,
because it may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may
cause the plastic surface to crack or deform.
CAUTIONS
!!
Checks before operation
Cleaning the air filter
Check that the wiring is not broken off or disconnected.
Check that the air filter is installed. (Some air-conditioners haven't air filters.)
Check that the outdoor unit air outlet or inlet is not blocked.
Before you clean the air conditioner, be sure to disconnect the power supply plug.
2. Take out the air-in grill (together with the air filter shown in Sketch B)
o
Pull the air-in grill down at 45 and lift it up to take out the grill.
3. Dismantle the air filter
4. Clean the air filter(Vacuum cleaner or pure water may be used to clean the air filter. If the dust
accumulation is too heavy , please use soft brush and mild detergent to clean it and dry out in cool
place) .
The air filter can prevent the dust or other particulate from going inside .In case of blockage of the filter , the
working efficiency of the air conditioner may greatly decrease .Therefore , the filter must be cleaned once two
weeks during long time usage.
If the air conditioner is positioned in a dust place , the cleaning frequency of the air filter must be increased .
If the accumulated dust is too heavy to be cleaned , please replace the filter with a new one(replaceable air
filter is an optional fitting).
A B
1. Open the air-in grill
Push the grill switches towards the middle simultaneously as indicated in sketch A. Then pull down
the air-in grill.
Cautions: The control box cables ,which are originally connected with the main body electrical terminators
must be pulled off before doing as indicated above.
Cassette Type
15
CAUTIONS
!!
Duct and Ceiling Type
Three-minute protection feature
Power failure
A protection feature prevents the air conditioner from being activated for approximately 3 minutes
when it restarts immediately after operation.
Power failure during operation will stop the unit completely.
Disconnect the unit with the power and then connect the unit with the power again. Push the ON/OFF
button on the remote controller to restart operation.
The OPERATION lamp on the indoor unit will start flashing when power is restored.
To restart operation, push the ON/OFF button on the remote controller.
Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.
Clip
Open<
2. Take out the air-in grill.
3. Dismantle the air filter
4. Clean the air filter (Vacuum cleaner or pure water may be used to clean the air filter. If the dust
accumulation is too heavy , please use soft brush and mild detergent to clean it and dry out in cool
place) .
1. Open the air-in grill
Push the grill switches towards the middle simultaneously as indicated in follow figure sketch.
Then pull down the air-in grill.
Cautions: The control box cables ,which are originally connected with the main body electrical
terminators must be pulled off before doing as indicated above.
Fig. 1 Fig. 2
The air-in side should face up when using vacuum cleaner. (See Fig. 1)
The air-in side should face down when using water. (See Fig. 2)
Cautions : Do not dry out the air filter under direct sunshine or with fire.
5. Re-install the air filter
6. Install and close the air-in grill in the reverse order of step 1 and 2 and connect the control box
cables to the corresponding terminators of the main body .
Note: High-static Pressure Parvis Split Type has no air filter.
16
AIR CONDITIONER OPERATIONS AND PERFORMANCE
Air conditioner operating conditions
Relocation
For proper performance, run the air conditioner under the following temperature conditions:
If you move out or if it is desired to relocate the air conditioner, consult your dealer, because special
skills to withdraw Freon, purge air and perform other operations are required.
If air conditioner is used beyond the above conditions, safety protection features may come into
operation.
Cooling operation
o
Outdoor temperature: 21 to 43 C
o
Outdoor temperature: -5 to 24 C
o
Outdoor temperature: 11 to 43 C
o
Room temperature: 17 to 32 C
o
Room temperature: 0 to 30 C
o
Room temperature: 17 to 30 C
CAUTION
Room relative humidity less than 80%. If the air conditioner
operates in excess of this figure, the surface of the air conditioner
may attract condensation.
Dry operation
Heating operating
(cooling only type without)
Location:
Be careful of noise or vibrations
Wire
During cooling operation, the air conditioner will dry the room air, so please fix a pipe to drain all the
water away from the air conditioner.
Please let the indoor unit more than one metre away from the TV set and the radio in order to avoid
the picture and noise interference.
Powerful radio transmitters or any other devices radiating high frequency radio waves can cause
the air conditioner to malfunction. Please consult the dealer where you purchased the air conditio-
ner before installing it.
Don't fix the unit in the dangerous region with combustible gas or volatile matter.
If the air conditioner operates in an atmosphere containing oils (machine oil), salt (near a coastal
area), sulfide gas (near a hot spring), etc., such substances may lead to failure of the air conditioner.
Please fix the unit in the stable place to avoid the noise or vibrations.
The noise near the air outlet of the outdoor unit may enter the air exit.
Locate the outdoor unit where noise emitted by it or hot air from its air outlet will cause no nuisance
to your neighbours.
If the air conditioner sounds abnormal during operation, contact the dealer where you purchased the
air conditioner.
To avoid the electric shock, please link the air conditioner with the ground. The plug in the air
conditioner has joined the ground wiring, please don't change it freely.
The power socket is used as the air conditioner specially.
Don't pull the power wiring hard.
When linking the air conditioner with the ground, observe the local rulers.
If necessary, use the power fuse or the circuit, breaker or the corresponding scale ampere.
If you want to change the power wiring, please contact the centre service of the local MD electric
appliance.
INSTALLATION
17
Before you ask for servicing or repairs, check the following points.
Setting Change is Impossible
Symptoms
Causes
Reason and Disposal
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
When the automatic mode is
selected, the air conditioner
automatically selects the fan
speed.
When dry operation is selected,
the air conditioner automatically
select the fan speed. The fan
speed can be selected during
"COOL" and "FAN ONLY", and
"HEAT"
TROUBLES AND CAUSES
(CONCERNING REMOTE
CONTROLLER)
TROUBLES AND CAUSES
Before you ask for servicing or repairs, check the following points.
The power fuse is blown or the circuit breaker has been tripped.
The batteries in the remote controller are exhausted.
The timer is set.
A bad odor comes from the air conditioner.
The air inlet or outlet of the outdoor unit is blocked.
Doors or windows are open.
The air filter is clogged with dust.
The louver is not at the correct position.
The fan speed is set to low.
The temperature setting is too high or too low.
Smells impregnated in the wall, carpet, furniture, clothing, or furs, are coming out. A white mist
of chilled air or water is generated from the outdoor unit.
The indicator lamps flash rapidly (five times per second), you disconnect the unit with the power
and then connect the unit with the power again after two or three minutes but the lamps still flash.
Switch operations are erratic.
The fuse is blown frequently or the circuit breaker is tripped frequently.
Foreign matter or water has fallen inside the air conditioner.
Any other unusual condition is observed.
Recheck
These are not failures
Inoperative
Room air is smelly.
Does not cool or heat well.
If any of the following conditions occur, stop the air conditioner immediately, set to off the power
switch, and contact the dealer:
CAUTION
!!
18
The Transmission Indicator " " Never Comes On
The Display Never Comes On
Symptoms
Symptoms
Causes
Causes
Reason and Disposal
Reason
The remote control signal is
not transmitted even when
the ON/OFF button is pushed.
The TEMP. indicator does
not come on.
Check whether the batteries
in the remote controller are
exhausted.
Check whether the MODE
indicated on the display is
"FAN ONLY".
FAN ONLY
The remote control signal is
not transmitted, because the
power supply is off.
The temperature cannot be
set during fan only operation.
The Display Goes Off
Symptoms
Causes
Reason
The indication on the display
disappears after a lapse of
time.
The ON TIMER indicators
go off after a lapse of certain
time.
Check whether the timer
operation has come to an
end when the OFF TIMER
is indicated on the display.
Check whether the timer
operation is started when
the ON TIMER is indicated
on the display.
The air conditioner operation
stops since the set time
elapsed.
When the time set to start the
air conditioner is reached, the
air conditioner will automatically
start and the appropriate
indicator will go off.
The Signal Receiving Tone does Not Sound
Symptoms
Causes
Disposal
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pushed.
Check whether the signal
transmitter of the remote
controller is properly directed
to the receiver of the indoor
unit when the ON/OFF button
is pushed.
Direct the signal transmitter of
the remote controller to the
receiver of the indoor unit, and
then repeatly push the ON/
OFF button twice.
Buttons on the remote
controller don't work.
Press Reset button.
19
MDV04U-008eW
2200017131
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Midea MCC48HRN1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Midea MCC48HRN1 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,96 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Midea MCC48HRN1

Midea MCC48HRN1 Gebruiksaanwijzing - Nederlands - 10 pagina's

Midea MCC48HRN1 Installatiehandleiding - English - 27 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info