611792
14
Verklein
Vergroot
Pagina terug
1/160
Pagina verder
EN
3
Simultaneous dual-arm
measurement and auscultatory
function for accurate office
blood pressure measurement.
Instruction Manual
WatchBP Office combines the advantages of an automatic blood pressure device and hybrid
sphygmomanometer and is designed to provide convenient, accurate and reliable in-office
blood pressure measurement following recommended guidelines of the European Society
of Hypertension (ESH), American Heart Association (AHA), and World Health Organization
(ESH)
1
.
1
O’Brien E, Asmar R, Beilin L, Imai Y, et al. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure
measurement. European Society of Hypertension Working Group on Blood Pressure Deviceing. J Hypertens 2003;21:821-848.
EN
Product description
Name of parts and display ..................................6-7
Components and accessories ............................. 8-9
Before using WatchBP Office
Selecting and fitting the correct cuff ...............10-11
Three operation modes
«AUSCULTATION» Mode ........................................ 12
«1st VISIT» Mode .............................................13-14
«FOLLOW-UP» Mode .............................................15
Taking measurements using WatchBP Office
«AUSCULTATION» Mode ...................................16-17
«1st VISIT» Mode .............................................18-20
«FOLLOW-UP» Mode ........................................21-23
Special Functions
Hiding measurement values ................................ 24
Mean arterial pressure and pulse pressure ......... 25
Taking fewer than three measurements ............ 26
Skipping the 60-second countdown .................... 26
Setting inflation pressure ..................................... 27
Setting measurement intervals ........................... 27
Viewing Measurements
«AUSCULTATION» Mode ....................................... 28
«1st VISIT» and «FOLLOW-UP» Mode ..............28-29
Controlling the WatchBP Office Wirelessly
Setting up the Bluetooth receiver ...................30-31
Installation of the software program ................... 32
Controlling the device wirelessly ...................32-33
Appendix
Rechargeable battery and power adaptor .......... 34
Troubleshooting ................................................... 35
Error messages ................................................36-37
Safety, care, accuracy test and disposal ..........38-39
Technical specifications ....................................... 40
Table of Contents
6
L
R
mmH g
mmHg
SYS
mmHg
DIA
SYS
DIA
mmHg
PUL
/min
AUSCULT 1st FOLLOW UP
L/R
3 sec.
INTERVAL
3 sec.
HIDE
7 sec.
PRESSURE
7 sec.
I/O switch
Bluetooth Switch
Main Adaptor Socket
Battery Compartment
Cuff Socket (L)
Cuff Socket (R)
Recharge Indicator
Display
M Button (Memory)
Mode Switch
Start/Stop Button
DC 6V 600mADC 6V 600mA
Product description
Name of parts
7
EN
Mean Arterial Pressure (MAP)
Pulse Pressure (PP)
Mode Indication
External Power
Bluetooth
Rest and Arm Position Reminder
Battery Symbol
Hide Display
Memory Mode
Pulse Rate
Heart Beat
L/R Cuff
Value for Left Arm
Systolic Value
Diastolic Value
Value for Right Arm
Systolic Value
Diastolic Value
Display
8
System Requirements: 550MHz CPU. 256MB Memory, 1024x768
pixel resolution, 256 color, CD-ROM drive, 1 free USB port, 40MB
free hard disk space, Microsoft Windows 2000 / XP / Vista.
Install CD
©
2
0
0
8
M
i
c
r
o
l
i
f
e
C
o
r
p
o
r
a
t
i
o
n
.
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
.
WatchBP Analyzer Office
Version 1.0.2.4
WatchBP Office and components
WatchBP Office blood
pressure device (1 pcs.)
WatchBP Office Software
CD X1
AC Adaptor X1 (Input:
100-240V~50/60Hz 0.7A
Output: +7.5V 2A)
M size (22cm~32cm) X2
L size (32cm~42cm) X2
Manual Instruction X1
Quick Start Guide X1
Bluetooth receiver X1
Install CD X1
mm H g
mmHg
SYS
mmHg
DIA
SYS
DIA
mmHg
PUL
/min
AUSCULT 1st FOLLOW UP
L/R
3 sec.
INTERVAL
3 sec.
HIDE
7 sec.
PRESSURE
7 sec.
Bluetooth Receiver
Driver
Install CD
How to take blood press sure measurement in three differe nt modes
Quick start guide
Flip over the quick start guide to see ‘Product description’.
1
Plug cuff connector
in the cuff socket
Turn on the device
Switch the mode
«1st VISIT» Mode (Double arm)
«FOLLOW-UP» Mode (Single arm)
«AUSCULTA TION» Mode
(Single arm)
Press Start/Stop
button to begin a
measurement
Note blood
presure using
auscultatory
method
Place the stethoscope on
the hollow of the elbow ,
over the brachial artery
Press Start/Stop
button to begin a
measurement
An averaged result will
be displayed after three
consecutive measurments
2
3
EN
9
Selective Cuffs
M (Medium size)
22 - 32 cm (8.7 - 12.6 inches)
With air tube 130 cm
*
Please contact Microlife or its distributor to purchase cuffs.
L (Large size)
32 - 42 cm (12.6 - 16.5 inches)
With air tube 130 cm
10
2–3cm
M (Medium size)
22 - 32 cm (8.75 - 12.5 inches)
M is the correct size for most people.
L (Large size)
32-42 cm (12.5-16.5 inches)
Before using WatchBP Office
Selecting the correct cuff
Two different cuff sizes are provided with the
WatchBP Office: Medium and Large. Select the cuff
size that best matches the circumference of the
patient’s upper arm.
Fitting the cuff properly
1) Place the cuff over the left (right) upper arm so
that the air tube and artery mark arrow point
toward the lower arm.
2) Lay the cuff on the arm. Make sure that the lower
edge of the cuff lies approximately ¾” to 1”(2 to
3cm) above the elbow.
Connect the cuff to the device by inserting the cuff
connector into the cuff connector socket.
R
R
EN
11
3) Wrap and tighten the cuff around the arm.
4) Leave a little free space between the arm and
the cuff. The patient should be able to fit 2 fingers
between the arm and the cuff. Clothing must not
restrict the arm. Remove all clothing covering or
constricting the measurement arm.
5) Cuffs that do not fit properly can result in
incorrect blood pressure measurements. Use a
different size cuff if the range Index at the end of
the cuff does not fall into the range specified by
the range stripes.
6) Apply the same steps to the other arm if a double
arm measurement is required.
*
The range index of cuff should
be fallen into this range.
12
AUSCULT 1st FOLLOW UPAUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP
Three operation modes
mmHg
mmHg
SYS
mmHg
DIA
SYS
DIA
mmHg
PUL
/min
AUSCULT 1st FOLLOW UP
L/R
3 sec.
INTERVAL
3 sec.
HIDE
7 sec.
PRESSURE
7 sec.
«AUSCULTATION» Mode
Select «AUSCULTATION» Mode for blood pressure
measurement of patients with arrhythmia, and,
if needed, to confirm if a patient is suitable for
the oscillometric method using a digital blood
pressure monitor.
Choose a desired operation mode
The WatchBP Office device includes three convenient
operation modes: «AUSCULTATION», «1st VISIT» and
«FOLLOW-UP» Mode. Use the Mode Switch on the
side of the device to select the desired mode.
AUSCULT 1st FOLLOW UPAUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP
EN
13
AUSCULT 1st FOLLOW UPAUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP
Simultaneous dual-arm measurements
In «1st VISIT» Mode, the WatchBP Office device
measures the patient’s blood pressure on both arms
simultaneously, helping to determine the preferred
measurement arm and reveal other potential
cardiovascular risks.
«1st VISIT» Mode
Select «1st VISIT» Mode to complete a fully-
automated triple measurement on both arms
according to recommended ESH/AHA blood
pressure measurement protocols for a patient’s
first office visit.
14
Automated triple measurement
In «1st VISIT» Mode, the WatchBP Office device
automatically takes three consecutive measurements
at one minute* intervals by default. The result of
these three measurements are averaged to produce
the first visit blood pressure measurement.
Determine proper measurement arm
If the measurement result between the two arms
differs more than 20mmHg for Systolic or 10mmHg
for Diastolic for all three measurements, the device
will indicate the higher measurement arm by a
flashing L or R.
Three operation modes (cont.)
1
2
3
60 sec. 60 sec.
*
The user can manually set up the measurement
interval of 15, 30, 45 or 60 seconds in 1st Visit and
Follow-up Mode. (Please refer to special functions
section page.24 “Set up measurement interval”).
The higher arm should be used as the preferred
measurement arm for future measurements.
EN
15
«FOLLOW-UP» Mode
Select «FOLLOW-UP» Mode to complete a fully-
automated triple measurement on the preferred
measurement arm. According to recommended
ESH/AHA blood pressure measurement protocols for
follow-up blood pressure measurement.
Automated triple measurement
In «FOLLOW-UP» Mode, the WatchBP Office
device automatically takes three consecutive
measurements at one minute intervals by default.
The result of these three measurements are
averaged to produce the follow-up visit blood
pressure measurement.
AUSCULT 1st FOLLOW UPAUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP
*
The user can manually set up the measurement
interval of 15, 30, 45 or 60 seconds in 1st Visit and
Follow-up Mode. (Please refer to special functions
section page 24 “Set up measurement interval”).
1
2
3
60 sec. 60 sec.
16
AUSCULT 1st FOLLOW UPAUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP
Taking measurements using WatchBP Office
«AUSCULTATION» Mode
1) Turn on the power Turn on the device by
switching the I/O switch at the back of the
device into the ON position and make sure
Bluetooth switch is in off position.
3) Switch to «AUSCULTATION» Mode Slide the
Mode Switch to «AUSCULTATION» Mode.
2) Apply the cuff* Properly fit one cuff to the
preferred measurement arm.
DC 6V 600mADC 6V 600mA
*
Additional visual instruction can be found on the cuff
4) Adjust inflation pressure if necessary
Inflation pressure can be set manually from 140
to 280 mmHg by pressing and holding the Start/
Stop Button for 7 seconds.
Press the M Button to adjust the pressure and
press Start/Stop to save the setting.
14

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Microlife WatchBP Office bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Microlife WatchBP Office in de taal/talen: Nederlands, Engels, Spaans als bijlage per email.

De handleiding is 7,13 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Microlife WatchBP Office

Microlife WatchBP Office Gebruiksaanwijzing - Deutsch, Français - 160 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info