600858
10
Verklein
Vergroot
Pagina terug
1/56
Pagina verder
10
ENGLISH
1. Component Overview
(Standard Delivery) .....................9
2. Please Read First! .....................10
3. Range of Application
and Pumping Media ..................10
4. Safety .........................................10
4.1 Specified conditions of use .........10
4.2 General safety information ..........10
5. Prior to Operation .....................11
5.1 Discharge hose connection.........11
5.2 Installation...................................11
6. Operation ...................................12
6.1 Automatic mode ..........................12
6.2 Manual mode ..............................12
7. Care and Maintenance..............12
7.1 Periodic maintenance..................12
7.2 Pump storage..............................12
8. Trouble Shooting ......................12
8.1 Fault finding.................................13
9. Repairs .......................................13
10. Environmental Protection ........13
11. Technical Specifications ..........13
These instructions are written in a way
that will enable you to safely use the
machine in a minimum of time. Here is
how to read the instructions:
Read these instructions completely
before use. Pay special attention to
the safety information.
These instructions are intended for
persons having a basic technical
knowledge in the handling of
machines such as the one
described here. If you have no expe
-
rience with this type of machine you
are advised to seek the advise of an
experienced individual before oper
-
ating this machine.
Keep all documents supplied with
the machine for future reference.
Retain proof of purchase for possi
-
ble warranty claims.
If you hire out or sell this machine be
sure to hand over the machine doc
-
uments supplied.
The equipment manufacturer is not
liable for any damage arising from
disregard of these instructions.
The information in these instructions is
denoted as under:
Danger!
Warning of personal
injury or environmental
damage.
Risk of electric shock!
Risk of personal injury
by electric shock.
Caution!
Risk of material damage
Note:
Supplementary information.
Numbers in illustrations (1, 2, 3, ...)
indicate component parts;
are consecutively numbered;
refer to the corresponding num-
bers in brackets (1), (2), (3) ... in
the neighbouring text.
Instructions to be carried out in
sequence are numbered.
Instructions which can be carried
out in any sequence are preceded
by a bullet (•).
Listing are preceded by a M-dash (–).
This pump is intended for pumping water
in domestic applications, such as
pumping containers, sumps and
flooded basements;
fountain pumps;
circulation to avoid putrefaction;
feeding false rivulets and brooks.
A
Caution!
The max. permissible fluid
temperature is 35
°C.
Pumping liquids containing abrasives
(such as sand) reduces the service
life of the pump.
4.1 Specified conditions of
use
This pump must not be used to
supply drinking water or for
pumping foodstuff.
Explosive, flammable, aggres-
sive fluids or substances detri-
mental to health, sewage must
not be pumped.
This pump is not suitable for
commercial or industrial use.
Any other use is not as speci-
fied. Use not as specified,
alteration of the machine or
use of parts that are not
approved by the equipment
manufacturer, can cause
unforeseeable damage!
4.2 General safety informa-
tion
This device is not designed for
use by persons (including chil
-
dren) with physical, sensory or
mental disabilities, or with
insufficient experience and/or
knowledge, unless they are
supervised by a person
responsible for their safety, or
have received instructions on
how to use the device by this
person.
Never allow children to use the
machine.
Children should be supervised
to ensure that they do not play
with the tool.
When used in swimming
pools
and garden ponds and
their range of protection, the
regulations according to
DIN
VDE 0100 -702, -738 are
to be observed.
Also all local regulations per-
taining to the safe operation of
submersible pumps must be
followed.
The following residual risks do
principally exist when operat
-
ing submersible pumps and
can not be fully eliminated –
even by employing safety
devices.
A
Hazard by ambient con-
ditions!
Do not use the pump in haz-
ardous locations or near
inflammable liquids and gases!
A
Danger: Hot water!
If the shut-off pressure of the
pressure switch cannot be
reached due to poor pressure
conditions or a defective pres
-
sure switch the water can heat
up within the pump as a result
of internal circulation.
Through this the pump and the
connection lines can become
damaged or leaky, allowing hot
water to escape. Danger of
scalding!
Do not operate the pump
against a closed pressure
line for longer than 5 minu
-
tes.
Table of Contents
2. Please Read First!
3. Range of Application and
Pumping Media
4. Safety
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Metabo TP 7500 SI bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Metabo TP 7500 SI in de taal/talen: Nederlands, Duits, Engels, Frans, Deens, Fins als bijlage per email.

De handleiding is 2,49 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info