658080
12
Verklein
Vergroot
Pagina terug
1/49
Pagina verder
12
ENGLISH
x Before each use check the pump,
especially the power cable and plug
for possible damage. Risk of fatal
electric shock!
x A damaged pump must be work-
manlike repaired before it can be
used again.
x Do not attempt to repair the pump
yourself! Only trained specialists are
permitted to service or repair pumps
or pressure vessels.
The pump is easily assembled and con-
nected.
If in doubt, contact your specialist sup-
plier or a qualified electrician.
5.1 Installation
The pump must be placed on a
plane and level surface, suitable of
bearing the weight of the pump fully
filled with water.
To avoid vibrations the pump should
be placed on an elastic base.
The installation location should be
well vented and protected from
atmospheric exposure.
When operated at garden ponds
and pools the pump must be set up
safe against flooding and safe-
garded against falling into the water.
Any additional legal requirements
are to be observed.
5.2 Connecting the Suction
Line
3
Note:
Possibly further accessories may
be required for connection (see "Availa-
ble Accessories").
A
Caution!
The suction line needs to be
installed in such manner that it does
not exert mechanical force or distor-
tion to the pump.
A
Caution!
When pumping contaminated
fluids install a suction strainer to pro-
tect the pump from sand and dirt.
3
Note:
A check valve is recommended to
prevent water backflow when the pump
is turned off.
All screw fittings must be sealed
with thread sealing tape; leaks
cause the priming of air, which
reduces or completely prevents the
priming of water.
The suction line should have an
inner diameter of 1" (25 mm) mini-
mum and must be kink and vacuum
resistent.
Keep suction line as short as practi-
cal, as with increasing length the
pump capacity is reduced.
The suction line should ascend
towards the pump to prevent air
locks.
A sufficient water supply must be
ensured, the foot valve at the end of
the suction line must be submerged
in water at all times.
5.3 Discharge Port
3
Note:
Possibly further accessories may
be required for connection (see "Availa-
ble Accessories").
A
Caution!
The discharge (or pressure)
line needs to be installed in such
manner that it does not exert mechan-
ical force or distortion to the pump.
All screw fittings should be sealed
with thread sealing tape to prevent
leakage.
All parts of the pressure line must be
resistant to internal pressure.
All parts of the pressure line must be
installed in a workmanlike manner.
A
Danger!
Improper installation and use
of parts not resistant to internal pres-
sure can cause the pressure line to
break during operation. Risk of per-
sonal injury by liquid spurting from
the line under high pressure!
5.4 Connection to a Pipe
System
A stationary installation (e.g. in an indoor
domestic water system) is also possible.
To reduce vibrations and noises the
pump should be connected to the
pipe system with flexible tubing.
5.5 Connection to AC Power
B
Danger! Risk of electric shock!
Do not operate the pump in wet
environment and only under the fol-
lowing conditions:
Connect only to an earthed outlet
that is properly installed, earthed
and tested.
Mains voltage and fuse protection
must correspond with the
requirement stated in the "Tech-
nical Specications".
When operated at pools, garden
ponds and similar locations, the
pump must be protected by a
residual current operated device
(RCD, 30 mA) (DIN VDE 0100 -702,
-738 or equivalent applicable
local regulations).
We recommend the use of RCD's
as a general precaution for per-
sonal protection.
When operating the pump out-
doors the electrical connections
must be splash-proof; the con-
nections must not be placed into
water.
Use only extension cables of suf-
ficient lead cross section (see
"Technical Specifications"). Com-
pletely unroll cable reels.
5.6 Filling the pump and
priming
A
Caution!
After installation, loss of water
or priming of air the pump needs to
be filled with water. Starting the pump
without water causes damage!
3
Note:
The suction line does not need to
be filled, the pump is self-priming. How-
ever, depending on length and diameter
of the suction line it may take some time
until pressure has built up.
1. Remove the water filler plug, com-
plete with gasket.
2. Slowly pour in clear water, until the
pump is filled.
3. To reduce the time needed for prim-
ing you can also fill the suction line.
4. Replace the water filler plug, com-
plete with gasket.
5. Open pressure line (open tap or
spray nozzle) for any air to escape
during priming.
6. Start pump (see "Operation").
7. Turn pump OFF when water runs
out steadily.
Pump and suction line must be con-
nected and filled (see "Prior to Opera-
tion").
A
Caution!
The pump must not run dry.
Ensure there is always sufficient
pumping medium (water) available.
x If the motor does not start, no pres-
sure is built up or similar effects are
evident, switch the pump OFF – and
try to resolve the fault (see "Trouble
Shooting").
Pump characteristic curve
The pump characteristic curve shows
which pump capacity is possible in
dependance on the delivery head.
5. Prior to Operation
6. Operation
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Metabo HWW 3000-20G bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Metabo HWW 3000-20G in de taal/talen: Nederlands, Duits, Engels, Frans, Spaans, Deens als bijlage per email.

De handleiding is 0,89 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info