Please read the instructions thoroughly before using the pump! Otherwise you may not use it!
This appliance is not suitable for use by persons (including children) with limited physical, sensory or mental
capabilities or lacking experience and/or knowledge, except if they are supervised by a person responsible
for their safety or have been instructed in the use of the appliance.
Children should be supervised in order to make sure that they do not play with the appliance.
Construction
These modern, powerful pumps are equipped with a single-phase alternating-current motor (canned motor
with capacitor). The motor is waterproof encapsulated in synthetic resin (IP68) and provided with
an overload protection.
Technische gegevens vindt u op het typeplaatje resp. in de tabel op pag. 1.
Use
These pumps are designed for the transport of water, for the operation
of fi lter systems,water displays, waterfalls, etc., as well as for oxygenating and circulating the water.
Area of application: garden ponds, fi shponds, outdoor and patio fountains! (see fi g. 1 + 2)
- Attention! Use in garden ponds and their protected zone is permitted only if the installation is
performed in compliance with the applicable regulations. Please consult a licensed electrician.
- Before performing any work on the pump, the fountain, or the pond, disconnect the mains
plug. Do not operate the pump if people are in the water! (disconnect the pump from the power
source)
Area of application: swimming pond or swimming pool (if people are in the water)! (see fi g. 3 + 4)
Pump suitable for installation and operation in systems and rooms according to DIN VDE 0100 Part 702 and
Part 737, if the erection requirements per DIN VDE 100 and the manufacturer’s specifi cations
(assembly and operating instructions) are followed.
Installation of these pumps at swimming ponds or swimming pools must comply with the following
standards: DIN EN 13451 Part 1 to Part 8, and DIN VDE 0100 Part 702 and Part 737.
Attention! Here operation of the pump is permitted only if the pump is permanently installed outside
of the water at least 2 m or more away from the pool.
The following measures must be undertaken: (see fi g. 3)
- Build a shaft with pedestal for the pump, at least 2 m away from the edge of the water.
- Protect the shaft with a cover.
- To protect the pump from fl ooding build a drain for the shaft.
- Attach the pump to the pedestal with screws.
- Install a “M” metal socket in the suction line, toward the pump, to connect to the equipotential bonding
of the swimming pond/swimming pool system!
- Please consult a licensed electrician. Also refer to “Non submersible use” and “Safety Measures.
Safety measures
- Before use: Check whether mains lead and plug are intact.
- Mains voltage and kind of current have to conform to the information on the type plate.
- The pump may only be connected to a proper earthing-contact type socket through a residual
current device (RCD, 30 mA).
- The connection box should be located in a water-protected area and at least 2 m away from the
edge of the water (see fi g. 1 + 2).
- Always keep the plug dry.
- Important! If the mains lead or the motor housing are damaged, the pump cannot be used anymore. It
cannot be repaired since the lead is permanently encapsulated in the motor housing.
- Do never hang up or transport the pump by the mains lead.
Start-up (see fi g. 1 - 4)
Important! Do not let the pump run „dry“. This could cause damages to the appliance.
- Immerse the pump completely in your pond. This causes the pump body to be fi lled with water.
- A minimum water depth of 25 cm is required for underwater operation to avoid the pump taking in air.
- The maximum depth for submerged operation of the
2 m
pump is 2 m!
- The water temperature may not exceed 35°C.
- The pump must be protected from frost.
- The pump is switched on by putting the plug in the socket.
- To prevent the pump becoming unnecessarily dirty, place it above the sludge deposits in your pond, in a
rm and horizontal position (on a stone slab)!
- A range of accessories may be fi tted onto the threaded connections of the pump.
GB
- TIP! The primary fi lters Ø 120 Art.-No. 168/009137 to 168/009140 may be used as intake protection
in clear water.
- The pressure duct can be mounted on top or on the side depending on the particulary implementation!
To do this loosen the screws (20) and turn the entire pump (10) to the desired position.
- Suitable fountain jets can be found in our range of accessoires (catalog).
“Non submersible use” (see fi g. 3 + 4)
The pump can be used in a nonsubmerged type application.
- Position the pump below the surface of the water, at the side of the pond so that the water can fl ow into the
pump (not self-priming).
- Connect suction hose (S) and pressure hose (D) to the pump. Connection should be watertight.
- Suction hose and pump must be fi lled with water before switching-on.
- TIP! To prevent the pump becoming clogged, provide the suction hose with a pre fi lter
Art.-No. 168 / 009050, 168 / 009051 or 168 / 009052 covered in our range of accessories.
Overload protection
In case the pump is becoming overheated the built-in thermal overload trip switches it off.
The pump must cool down.
The pump will not start automatically without the necessary controlling when it is cool.
Check the following operating conditions:
- Is there a suffi cient water supply?
- Has the fi lter become clogged?
- Has dirt entered the pump housing (Follow the cleaning instructions below)?
- Have hoses or jets become clogged?
- Has the pump cooled down?
As soon as you have solved the problems, you can switch on the pump again by pulling the plug out of the
socket and putting it in again after a short time (1 min.)
Dismantling (see fi g. 5)
1. Follow the safety measures. Disconnect pump from mains!
2. Loosen the 4 screws (18).
3. Pull apart pump housing (12) and motor housing (10) .
4. Remove rotor assembly (15) from motor housing (10). Take care of the O-ring (16) on the motor
housing (10).
5. Clean all parts with clear water and a soft sponge. Note! In case of massive calcination please use
MESSNER decalcifi er for pumps Art.-No. 168 / 009115.
Assembly (see fi g. 5)
1. Push the O-ring (16) onto the starting point on the motor housing (10).
2. Carefully slide the rotor assembly (15) into the motor housing (10) and twist the bearing cover so that
the two holes fi t onto the pins on the motor housing (10).
3. Check whether the rotor assembly can be rotated easily.
4. Check the position of the O-ring (16) on the motor housing (10).
5. Put the pump housing (12) on the motor housing (10) and attach it fi rmly and evenly with the
4 screws (18) .
Maintenance
In order to prolong the service life of your pump signifi cantly and to keep it in sound operating condition, it is
recommended to carry out maintenance and cleanup regularly.
This can be done by everyone, quickly and easily. See „Dismantling/Assembly“
Servicing intervals
- In the beginning check proper performance of your pump every day. If necessary, clean the fi lters.
- Since servicing intervals (complete cleaning) will vary depending on the level of pond pollution, repeat the
periodic service to your pump in accordance with the pollution of the pond water .
Should you determine that there are damaged or worn parts, replace them. See „Spare parts“
Important! When used in calcareous water, the rotor assembly (15) and the stainless steel can split
tube in the motor housing (10) should be cleaned at regular intervals.
Pump care in wintertime
Protect your pump from freezing-up!
Take the pump out of your pond in autumn. Clean the pump completely according to the instructions.
During the winter months store the pump in a tank fi lled with water to prevent the bearings from drying out.
Store the tank in a frostproof room.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Messner power-Tec2 10000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Messner power-Tec2 10000 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans als bijlage per email.

De handleiding is 0,58 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info