664266
4
Verklein
Vergroot
Pagina terug
1/124
Pagina verder
4
POWER REQUIREMENTS
ENGLISH
GROUNDING INSTRUCTIONS
The equipment must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock. The unit is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances. If the user does not follow these
grounding instructions, the user could void the Matrix limited warranty.
ADDITIONAL ELECTRICAL INFO
In addition to the dedicated circuit requirement, the proper gauge wire
must be used from the circuit breaker box, to each outlet that will have
the maximum number of units running off of it. If the distance from the
circuit breaker box to each outlet, is 100 ft (30.5 m) or less, then 12 gauge
wire should be used. For distances greater than 100 ft (30.5 m) from the
circuit breaker box to the outlet, a 10 gauge wire should be used.
ENERGY SAVING / LOW-POWER MODE
All units are congured with the ability to enter into an energy saving / low-
power mode when the unit has not been in use for a specied period of
time. Additional time may be required to fully reactivate this unit once it has
entered the low-power mode. This energy saving feature may be enabled
or disabled from within the ‘Manager Mode’ or ‘Engineering Mode.’
ADD-ON DIGITAL TV (T1X AND T3X)
A 15 A or 20 A “Dedicated Circuit” with a non-looped (isolated) neutral/ground
is required. Each add-on TV requires at least 1.2 A of current (at 110 V or 220
V). No more than 12 add-on TVs should be used for each 15 A circuit and no
more than 16 add-on TVs should be used for each 20 A circuit. The power outlet
should have the same conguration as the plug. No adapter should be used
with this product. An RG6 coaxial cable with ‘F Type’ compression ttings will
need to be connected between the video source and each add-on TV unit.
DEDICATED CIRCUIT AND ELECTRICAL INFO
A “Dedicated Circuit” means that each outlet you plug into should not have
anything else running on that same circuit. The easiest way to verify this is
to locate the main circuit breaker box, and turn off the breaker(s) one at a
time. Once a breaker has been turned off, the only thing that should not have
power to it are the units in question. No lamps, vending machines, fans, sound
systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have an individual
neutral/ground connection coming from it, and terminating at an approved earth
ground. You cannot “jumper” a single neutral/ground from one circuit to the next.
ELECTRICAL REQUIREMENTS
For your safety and to ensure good treadmill performance, the ground
on this circuit must be non-looped (isolated). Please refer to NEC
article 210-21 and 210-23. Your treadmill is provided with a power cord
with a plug listed below and requires the listed outlet. Any alterations
of this power cord could void all warranties of this product.
For units with an integrated TV (like the 1xe, 3xe and 3xh), the TV
power requirements are included in the unit. An RG6 coaxial cable
with ‘F Type’ compression ttings on each end will need to be
connected to the cardio unit and the video source. For units with
an add-on digital TV (1x, 3x only), the machine in which the add-on
digital TV is connected to powers the add-on digital TV. Additional
power requirements are not needed for the add-on digital TV.
110 V UNITS
All Matrix 110 V treadmills require the use of a 100-125 V, 60 Hz and a
20 A “Dedicated Circuit”, with a non-looped (isolated) neutral/ground
for power. This outlet should be a NEMA 5-20R and have the same
conguration as the plug. No adapter should be used with this product.
220 V UNITS
All Matrix 220 V treadmills require the use of a 216-250 V, 50 Hz and a
20 A “Dedicated Circuit”, with a non-looped (isolated) neutral/ground
for power. This outlet should be a NEMA 6-20R and have the same
conguration as the plug. No adapter should be used with this product.
North American and
European power
cord plugs shown.
Depending on your
country, the plug
type may vary.
110 NEMA 5-20P
PLUG (N.A.)
220 NEMA 6-20P
PLUG (N.A.)
EURO PLUG
(EUROPE)
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Matrix T3x bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Matrix T3x in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens als bijlage per email.

De handleiding is 26,09 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Matrix T3x

Matrix T3x Gebruiksaanwijzing - Nederlands, Deutsch, English - 68 pagina's

Matrix T3x Gebruiksaanwijzing - English - 52 pagina's

Matrix T3x Gebruiksaanwijzing - English - 16 pagina's

Matrix T3x Gebruiksaanwijzing - Français, Italiano, Português, Espanõl, Polski - 68 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info