785651
4
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
MasterBus AC Master Interface
Interface from MasterBus to AC Master
USER AND INSTALLATION MANUAL
10000014535/02
2
AC Master Interface
User and Installation Manual
1 GENERAL INFORMATION
Use of this manual
This manual serves as a guideline for the safe and effective operation of the MasterBus AC Master Interface.
Keep this manual at a secure place!
Warranty
Mastervolt assures the product warranty of the AC Master Interface during two years after purchase, on the
condition that the product is installed and used according to the instructions in this manual.
Installation or use not according to these instructions may result in under performance, damage or failure of the
product and may void this warranty. The warranty is limited to the cost of repair and/or replacement of the
product. Costs of labour or shipping are not covered by this warranty.
CAUTION!
Never remove the identification label.
Liability
Mastervolt can accept no liability for:
consequential damage due to use of the AC Master Interface;
possible errors in the manuals and the results thereof;
use that is inconsistent with the purpose of the product.
Disclaimer
Our products are subject to continual development and improvement. Therefore, additions or modifications to the
products may cause changes to the technical data and functional specifications. No rights can be derived from
this document. Please consult our online Terms & Conditions of Sale.
Correct disposal of this product
This product is designed and manufactured with high quality materials and components, which
can be recycled and reused. When this crossed-out wheeled bin symbol is attached to a product,
it means the product is covered by the European Directive 2012/19/EU.
Please be informed about the local separate collection system for electrical and electronic
products.
Please act according to your local rules and do not dispose of your old products with your normal household
waste. The correct disposal of your old product will help prevent potential negative consequences to the
environment and human health.
2 COMPATIBILITY
The AC Master Interface supports the following AC Master sine wave inverters:
AC Master 12/700
AC Master 24/700
AC Master 12/1000
AC Master 24/1000
AC Master 12/1500
AC Master 24/1500
AC Master 12/2000
AC Master 24/2000
AC Master 12/2500
AC Master 24/2500
AC Master 12/3500
AC Master Interface – User and Installation Manual
3
3 INSTALLATION
Steps:
The step numbers correspond to the numbers in the drawing.
Mount the AC Master Interface to any flat surface. The AC Master Interface
comes with a DIN rail mount option. Alternatively, use the two mounting
holes.
Insert the RJ11 cable (included, 1m) and connect to the remote input of the
AC Master inverter.
Insert the MasterBus cable (included, 1m) and make sure that the MasterBus
network is properly terminated at the two ends with a terminating device (one
included).
A flashing LED indicates that the MasterBus communication is working.
4 OPERATION
The following table shows the AC Master Interface MasterBus functions.
MONITORING DESCRIPTION ADJUSTABLE RANGE
General
Device state Shows the current operation mode:
Not connected, On, Bypass, Alarm
(read only)
On/Off Button to switch the device on or off [default: On] On, Off
Battery
Voltage Battery voltage (read only)
AC input
Voltage Input voltage (read only)
Power Input power (read only)
AC output
Voltage Output voltage (read only)
Power Output power (read only)
Frequency Output frequency (read only)
ALARM
High battery High battery voltage alarm (read only)
Low battery Low battery voltage alarm (read only)
Temperature AC Master temperature is too high (read only)
Overload Output overload (read only)
System error AC Master error (read only)
CONFIGURATION
Device
Language Interface menu language on a monitoring device connected
to the MasterBus network [default: English]
EN, NL
Name User defined device name, visible throughout the MasterBus
network [default: AC Master]
Up to 12 Characters
Type AC master model (read only)
EVENTS
Event target Select a target device in your system System dependent
Event command Select a command Target dependent
Event data Select the way the command should act on the source See relevant product manual
4
AC Master Interface
– User and Installation Manual
The previous table lists the events with the interface as source. The AC Master Interface can also serve as target.
It can be switched On and Standby in the configuration of another MasterBus device.
CONFIGURATION DESCRIPTION ADJUSTABLE RANGE
Device Event command
Select a command from the drop-down list [default disabled] On, By-pass, Alarm
5 SPECIFICATIONS
Model: MasterBus AC Master Interface
Product code: 77032700
Delivery also includes: – MasterBus terminating device
– MasterBus cable (1m)
– RJ11 cable (1m)
– User manual
Languages available: English, Dutch
Current consumption: 35 mA
MasterBus Powering: No
DIN rail mounting: Yes, DIN rail 30 mm [1.2 inch]
Protection degree: IP 21
Dimensions: 66 x 78 x 32 mm [2.6 x 3.1 x 1.3 inch]
Weight: 70 g [0.15 lb]
Dimensions in mm [inch]
Mastervolt B.V.
Snijdersbergweg 93
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Email: info@mastervolt.com
Web:
www.mastervolt.com
Copyright © 2018 Mastervolt. All rights reserved.
Reproduction, transfer, distribution or storage of part or all of the contents in this
document in any form without the prior written permission of Mastervolt is prohibited.
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Mastervolt MasterBus AC Master Interface bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Mastervolt MasterBus AC Master Interface in de taal/talen: Engels als bijlage per email.

De handleiding is 0.88 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info