3.3.1.3 STOP SUMMARY TABLE
The stop summary table lists each individual
stop in depth and duration, including safety,
deco and deep stops. This table does not
appear as long as you are in a no deco dive
without deep stop requirement.
This table is especially useful during
decompression dives since it breaks down the
entire ascent into each individual stop.
To call up the stop summary table, press the
bottom left button.
The stop summary table has an 8-second
time-out, after which the screen automatically
reverts to the default computer display. You
can exit the stop summary table before the 8
seconds are passed by pressing the top left
button.
NOTE
In the event of an alarm, Matrix
automatically switches back to the default
computer display.
3.4 AFTER THE DIVE
Upon returning to the surface, Matrix first
goes into the so-called surfacing mode. This
mode allows you to resume your dive after a
brief period of orientation. The screen shows
a 3-minute countdown, a profile of the dive,
your maximum depth and the dive time. During
surfacing mode you can call up the compass by
pressing and holding the top left button.
If you submerge again before the 3-minute
countdown is over, the dive time will resume
from where it left off, including the time spent
on the surface. If you do not submerge before
the end of the countdown, Matrix considers the
dive finished, records the data to the logbook
and reverts to the so-called post-dive mode.
The post-dive screen shows the following
information:
- The remaining desaturation time (DESAT):
this is calculated by the decompression
model in the computer. Any dive started
while there is remaining desaturation on
your computer is considered a repetitive
dive, meaning that Matrix accounts for the
pre-existing nitrogen load in your body.
- The no-fly time (NO
): this is the time
during which an exposure to the reduced
pressure inside the cabin of an airplane
could cause decompression sickness. Matrix
employs, as recommended by NOAA, DAN
and other agencies, a standard 12-hour
(no-deco non-repetitive dives) or 24-hour
(deco and/or repetitive dives) countdown.
Hence you may find a situation in which the
desaturation time is shorter than the no-fly
time. This is simply the consequence of the
desaturation time being calculated by the
algorithm based on the actual dive profile,
while the no-fly time is an accepted standard
in the diving industry. Since the real effect of
flying after diving has never been fully
investigated, this approach fits with our
philosophy.
WARNING
Flying while Matrix displays NO
can
result in serious injury or death.
- The surface interval (SURF): this is displayed
from the moment the dive is closed (3
minutes after surfacing) for as long as there
is remaining desaturation or no-fly time on
the computer.
- In case of a dive violation, the corresponding
symbol (
, ) is shown next to the surface
interval.
In addition, the left bar graph shows the
calculated nitrogen load in the leading tissue.
You can use this to gauge your progress
in getting rid of nitrogen as the surface
interval grows. Matrix continues to perform
decompression-related calculations (nitrogen
release), for as long as there is desaturation
time left.
During post-dive mode you can revert to the
regular watch display by pressing the top left
button. You can return to the post-dive screen
again by pressing the top left button.
From the post-dive screen you can also jump
directly to the log of the last dive by pressing
and holding the top right button.
3.5 DIVING WITH MORE THAN ONE
GAS MIXTURE
WARNING
- Diving with more than one gas mixture
represents a much higher risk than
diving with a single gas mixture, and
mistakes by the diver may lead to
serious injury or death.
- During dives with more than one gas
mixture, always make sure you are
breathing from the tank that you intend
to breathe from. Breathing from a high
oxygen concentration mix at the wrong
depth can kill you instantly.
- Mark all your regulators and tanks so
that you cannot confuse them under any
circumstance.
- Before each dive and after changing
a tank, ensure that each gas mixture
is set to the correct value for the
corresponding tank.
Matrix enables you to use up to three gas
mixtures during the dive (air and Nitrox
only). The three mixtures are labeled G1, G2
and G3 and must be in ascending order of
oxygen content, i.e. G1 has the lowest oxygen
concentration, G2 an intermediate value, and
G3 has the highest oxygen concentration of the
three. If you are diving with only two mixtures,
you will be utilizing tanks G1 and G2.
WARNING
It is not possible to switch to a gas at a
depth at which the oxygen partial pressure
for that gas is greater than the set
maximum value.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Mares Matrix bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Mares Matrix in de taal/talen: Engels als bijlage per email.

De handleiding is 6,57 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Mares Matrix

Mares Matrix Gebruiksaanwijzing - Nederlands - 20 pagina's

Mares Matrix Gebruiksaanwijzing - Deutsch - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info