2.4 DIVE PLANNER
This function allows you to scroll through the
no decompression limits, automatically taking
into account the current residual saturation
of the tissue compartments from a preceding
dive. The times shown when scrolling the
no decompression limits take into account
the information entered under the set dive
submenu: altitude, personal safety factor,
Air, or in the case of Nitrox, the values for the
oxygen percentage and its maximum partial
pressure. For each depth, the display shows
the corresponding no deco time expressed
in minutes. If Nitrox mode is selected, the
maximum depth shown in the planner is
limited by the MOD.
NOTE
The dive planner is enabled only if either
air or nitrox mode is set
2.5 INFO
This submenu provides information about the
hardware and software of your Matrix.
3 DIVING WITH MATRIX
3.1 A FEW WORDS ABOUT NITROX
Nitrox is the term used to describe breathing
gases made of oxygen-nitrogen mixes with
an oxygen percentage higher than 21% (air).
Because Nitrox contains less nitrogen than
air, there is less nitrogen loading on the
diver’s body at the same depth as compared to
breathing air.
However, the increase in oxygen concentration
in Nitrox implies an increase in oxygen partial
pressure in the breathing mix at the same
depth. At higher than atmospheric partial
pressures, oxygen can have toxic effects on the
human body. These can be lumped into two
categories:
- Sudden effects due to oxygen partial
pressure over 1.4bar. These are not related
to the length of the exposure to high partial
pressure oxygen, and can vary in terms
of the exact level of partial pressure they
happen at. It is commonly accepted that
partial pressures up to 1.4bar are tolerable,
and several training agencies advocate
maximum oxygen partial pressures up to
1.6bar.
- Long exposure effects to oxygen partial
pressures over 0.5bar due to repeated and/
or long dives. These can affect the central
nervous system, cause damage to lungs or
to other vital organs.
Matrix keeps you safe with respect to these
two effects in the following ways (as long as it
is set to either air or nitrox):
Against sudden effects: Matrix has an MOD
alarm set for a user-defined ppO
2
max. As
you enter the oxygen concentration for the
dive, Matrix shows you the corresponding
MOD for the defined ppO
2
max. The default
value of ppO
2
max from the factory is 1.4bar.
This can be adjusted to your preference
between 1.2 and 1.6bar. Please refer to
section 2.2.1.1 for more information on how
to change this setting. If Matrix is set to air,
the ppO
2
max is set to 1.4bar by default.
Against long exposure effects: Matrix
“tracks” the exposure by means of the
CNS % (Central Nervous System). At levels
of 100% and higher there is risk of long
exposure effects, and consequently Matrix
will activate an alarm when this level of
CNS% is reached. Matrix also warns you
when the CNS level reaches 75%. Note that
the CNS% is independent of the value of
ppO
2
max set by the user.
3.2 ALARMS
Matrix can alert you of potentially dangerous
situations. There are five different alarms:
- Ascent rate alarm;
- Exceeding a safe ppO
2
/MOD;
- CNS =100%;
- Missed decompression stop;
- Low battery during the dive
WARNING
When in bottom timer mode, all warnings
and all alarms are OFF aside for the low
battery alarm.
NOTE
- Alarms are both visual and audible, as
described in detail below.
- If you are in compass mode when an
alarm is triggered, Matrix will revert to
the default computer display in order to
properly display the message related to
the alarm.
- Ascent rate alarm has priority over
other alarms if they are triggered
simultaneously.
3.2.1 ASCENT RATE
As soon as depth decreases Matrix activates
the ascent rate control algorithm and displays
the calculated value. This is shown in lieu of
the dive time in the bottom left corner for the
duration of the ascent.
WARNING
A rapid ascent increases the risk of
decompression sickness.
If Matrix determines an ascent rate of 10m/
min / 30ft/min or higher, the fast ascent alarm
is triggered: an audible alarm goes off and
the message SLOW DOWN is displayed at the
bottom of the screen. This persists until the
ascent rate is reduced to 10m/min / 30ft/min
or less.
If the ascent rate exceeds 12m/min / 40ft/min
at a depth below 12m / 40ft, the message on
the screen changes to TOO FAST. If a speed in
excess of 12m/min / 40ft/min is maintained for
two thirds or more of the depth at which the
alarm was first triggered, Matrix considers it a
dive violation and the display will show .
In this case, if the diver attempts a repetitive
dive after surfacing, Matrix will only function
as a depth gauge and timer (bottom timer
mode), and will display the message LOCKED
in the middle of the screen.
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Mares Matrix bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Mares Matrix in de taal/talen: Engels als bijlage per email.

De handleiding is 6,57 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Mares Matrix

Mares Matrix Gebruiksaanwijzing - Nederlands - 20 pagina's

Mares Matrix Gebruiksaanwijzing - Deutsch - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info