English - Page 8
1.3.1 Overview of the extended operator functions
Level Functions Explanation Factory settings
3rd programming
level
Automatic timer
function
Open door time The time the door is open before it closes automatically.
Automatic timer
function deactivated
Warning time
The time the signal light is flashing before the door
closes automatically.
Automatic timer
function deactivated
Warning before start
The time the signal light flashes before the door starts
to move.
0 seconds
Early closing after having
passed the photocell
The door closes either after the set open time or earlier
after having passed the photocell.
No
Signal lights
The signal light function can be set to flashing or to
permanent light.
Flashing light
4th programming
level
Parameter
Excess travel stop
The time period after which the operator cuts out
without having reached an end position.
55 seconds
Offset learned power limit The learned power limit can be set in steps from 1 - 16. Step 4
Sensitivity power limit
The sensitivity of the power limit can be set in steps
from 1 - 16.
Step 13
6th programming
level
Reversion
modes
Power limit OPEN
Setting whether the operator stops, short or long
reversion.
Stop
Power limit CLOSE
Setting whether the operator stops, short or long
reversion.
Stop
Activation of photocell /
photocell CLOSE
Setting whether the operator stops, short or long
reversion.
not existing
Closing edge safety device
CLOSE
Setting whether the operator stops, short or long
reversion.
short reversion
8th programming
level
Operating
modes
Press-and-hold OPEN After start the operator runs to the selected position. On
Press-and-hold CLOSE After start the operator runs to the selected position. On
Impulse commands
Activation of the impulse button when the operator
runs.
No
Direction commands
(Pushbutton OPEN or CLOSE)
Activation of the direction button when the operator
runs.
Yes
1. Programming
1.3 Extended operator functions (only for specialist personnel)