742891
69
Verklein
Vergroot
Pagina terug
1/84
Pagina verder
Instructions for Initial Operation and
Wiring Plan Manual
Control Unit for Industrial Doors
GB
Control 144/145/145 FU
Please keep these instructions for further reference.
English / Page 2
1. Contents
Chapter Page
1. Contents 2
2. Meaning of Symbols 3
3. Pictures to Control Unit Control 144 / 145 / 145 FU 5
4. Important Safety Advice 7
5. Initial Operation of Control Units Control 144 / 145 / 145 FU 9
5.1 Connection Control Unit - Operator 9
5.1.1 Dynamic 121 - 128 and Dynamic 300 - 301 10
5.1.2 Dynamic 3-101 - 3-108 10
5.1.3 Dynamic 3-103 FU - 3-118 FU 11
5.2 Connection Control Unit - Door Leaf 13
5.3 Initial Operation 14
5.4 Setting the Reference Point 16
5.4.1 Dynamic 121 - 128 and Dynamic 300 - 301 16
5.4.2 Dynamic 3-101 - 3-118FU 18
6. Display Functions and Programming Functions 19
6.1 Summary of Display Functions and Programming Possibilities 19
6.2 Basic Functions of the Operator 23
6.3 Extended Operator Functions 36
7. Connection of the Closing Edge Safety Device 52
8. Connection and Initial Operation of the Accessories 54
8.1 Remote Control 54
8.2 External Control Elements 55
8.2.1 with System Plug 55
8.2.2 without System Plug 56
8.3 Photocell 59
8.4 Connection of Extension Units for Control Inputs 61
8.5 Connection of Extension Units for Control Exits 63
8.5.1 Information on End Positions (Relay) 64
8.5.2 Signal Light Connection for Automatic Timer Function 65
8.5.3 Signal Light Connection for Traffic Control Function 66
8.5.4 Lighting (Relay for Special Functions) 67
9. Appendix 68
9.1 Wiring Plans 68
9.1.1 Wiring Plan Control 144 68
9.1.2 Wiring Plan Control 145 70
9.1.3 Wiring Plan Control 145 FU 72
9.2 Error Numbers 74
9.3 Test Instructions 76
9.4 Technical Data 80
Warning! Risk of personal injury!
There follow important safety advice which must be followed
in order to prevent personal injuries!
Attention! Risk of material damage!
There follow important safety advice which must be followed
in order to prevent material damage!
2. Meaning of Symbols
English / Page 3
Operational check:
After connecting and programming most of the control
elements, it is advisable to test the function of the control unit.
Any fault can then be detected immediately and time is saved
in trouble-shooting.
Advice / Tip
English / Page 4
2. Meaning of Symbols
On, mains voltage
Impulse
Malfunction
Travel limit OPEN
Travel limit CLOSE
Power limit
Stop
External control elements
Electronic aerial
Photocell
Transmitter
(optosensor, photocell)
Receiver
(optosensor, photocell)
Closing edge safety device
RPM sensor
To control unit
Cable slack switch
Connection lead
Wicket door switch
Automatic timer
Lighting
Symbols of control unit, operator etc.:
Fig. 3: Control panel of control unit
Fig. 1: Overview of door and surrounding area
D
C
A
B
F
E
Fig. 2: Membrane keypad and key switch
3. Pictures to Control Unit Control 144 / 145 / 145 FU
English / Page 5
Overview of door and surrounding
area:
A Control panel of control unit
B Connectons in control unit
C Connections in door operator
D Setting the reference point
E Site electric socket CEE-Standard 16A
F Connection to door leaf
Key switch:
0red OFF
1blueON
LED’s:
1. Photocell
2. Travel limit OPEN
3. Times for automatic timer
4. Travel limit CLOSE
5. Reference point
6. Malfunction
7. Impulse
8. Voltage
15. Closing edge safety device
Control elements:
10. PROGRAMMING button
11. OPEN button
12. CLOSE button
13. STOP button
3
1
15
2
12
11
13
0
I
P
5
2 3 1
O
8
O
1
O
2
O
3
O
11
O
10
O
7
O
6
O
5
O
4
O
12
English / Page 6
3. Pictures to Control Unit Control 144 / 145 / 145 FU
Plug connections:
25. X30 Closing edge safety device
CLOSED
26. X20a Electronic aerial
27. X10 External control elements
28. X20 Photocell
29. X40 RPM sensor
30. X31 Closing edge safety device
OPEN
31. X5 Keypad on cover
32. X8b Signal light relay
33. X8a Limit relay
34. X8c Traffic control relay
35. X8d Relay for special functions
38. X5E Circuit board for button
connection
Connecting terminals:
39. X2c External control elements
Programming buttons:
36. S20 Photocell function
37. S20a Photocell function
Fig. 4: Connections in control unit
P
X32
X10
X20
X20a
X30
X40
F4
6,3A
F3
6,3A
F2
6,3A
F1
125mA
6,3A
F1
3
4UVVW
L1
L2 L2 L3 N N
5
1213 20 21 1415 1617
X3
X2
C
D
ON
OFF
O
38
O
32
O
34
O
30
O
36
O
37
O
33
O
32
O
35
O
31
O
39
O
25
O
29
O
27
O
28
O
26
4. Important Safety Advice
English / Page 7
This control unit may only be connected and put into operation by qualified and
suitably trained specialist personnel. For the purpose of this description qualified
and suitably trained specialist personnel are persons who are adequately instructed
or supervised by qualified electricians and are thus in a position to recognize
the hazards that electricity can cause. Moreover, they must hold qualifications
consistent with the work being carried out. This presupposes in particular
knowledge of applicable electro-technological regulations,
training in the use and maintenance of adequate safety equipment,
first aid training.
Attention!
Before carrying out any cabling work, it is essential to
disconnect the control unit from the mains supply.
Observe local safety regulations!
Always lay mains cable and control cable separately.
Control voltage 24 V DC.
Attention!
Before putting the control unit into operation, it is essential to
ensure, that there are no persons or objects within the door's
aeria of operation, since a number of settings set the door in
motion!
All available emergency command devices must be tested prior to initial
operation.
The door operator must be installed with the door closed!
After installation and initial operation, those persons or their representatives
responsible for operating the door system must be shown how the door
system works!
No cables should be fed into the top of the control unit!
For technical reasons, the first time the control unit is switched on and after
actuating the control elements, the door travels to its end position OPEN.
English / Page 8
4. Important Safety Advice
Attention!
Special note for installation according to protection category IP 65:
At the very latest following initial operation, the cable with
plug allowing connection to the mains must be replaced by
a fixed direct mains connection. At the same time a mains
isolator switch must be fitted.
Attention!
Non-compliance with this warning and safety instructions can
lead to personal injury and material damage.
5. Initial Operation of Control Unit Control 144 / 145 / 145 FU
English / Page 9
5.1 Connection control unit - door operator
Connect control unit according to fig. 5 or 7.
Connections in control unit:
50. Protective conductor
51. Power cable operator
52. RPM sensor
Legend wiring plans:
ST1 Control unit
A1 Door operator
Connecting terminals
X3 Power cable operator
X3a Motor
Plug conections:
X40 RPM sensor
X41 RPM sensor
Fig. 5: Connections in control unit Control 144 Fig. 7: Connections in control unit Control 145
Fig. 6: Wiring plan with control unit Control 144 Fig. 8: Wiring plan with control unit Control 145
51 50 52
51 50 52
Fig. 10: Connections in door operator
Fig. 9: Connections in door operator
5.1.2 Dynamic 3-101 - 3-108
Connect control unit to door operator according to fig. 10.
English / Page 10
5. Initial Operation of Control Unit Control 144 / 145 / 145 FU
5.1.1 Dynamic 121 - 128 / Dynamic 300 - 301
Connect control unit to door operator according to fig. 9.
56
55
54
Connections in door operator:
54. Protective conductor
55. Motor
56. RPM sensor
Connections in door operator:
54. Protective conductor
55. Motor
56. RPM sensor
O
56
O
55
O
54
69

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Marantec Control 145 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Marantec Control 145 in de taal/talen: Engels als bijlage per email.

De handleiding is 2,35 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Marantec Control 145

Marantec Control 145 Gebruiksaanwijzing - Nederlands - 42 pagina's

Marantec Control 145 Gebruiksaanwijzing - Deutsch - 84 pagina's

Marantec Control 145 Gebruiksaanwijzing - Français - 42 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info