8. Connection and Initial Operation of the Accessories
English / Page 57
Connection plan: Control elements S2 and S4 are active when the operator is running:
Following functions are available at connecting terminal X2c:
S0 (STOP): Connection: terminals 12 and 13 (remove short-circuit plug)
Contact category: opener
Connection mode: several contacts have to be connected in series!
S1 (IMPULSE): Connection: terminals 20 and 21
Contact category: closer
Connection mode: several contacts have to be connected parallelly!
S2 (OPEN): Connection: terminals 16 and 15
Contact category: closer
Connection mode: several contacts have to be connected parallelly!
S4 (CLOSE): Connection: terminals 16 and 17
Contact category: closer
Connection mode: several contacts have to be connected parallelly!
Fig. 20: Wiring diagram Fig. 21: Wiring diagram